Comparative analysis of peak-detection techniques for comprehensive two-dimensional chromatography

被引:28
作者
Latha, Indu [1 ]
Reichenbach, Stephen E. [1 ]
Tao, Qingping [2 ]
机构
[1] Univ Nebraska, Dept Comp Sci & Engn, Lincoln, NE 68588 USA
[2] GC Image LLC, Lincoln, NE 68505 USA
基金
美国国家科学基金会;
关键词
Two-dimensional chromatography; Comprehensive two-dimensional gas chromatography (GCxGC); Chemometrics; Peak detection; Watershed algorithm; Two-step peak detection; GAS-CHROMATOGRAPHY; GC; ALGORITHM; NUMBER; MODEL;
D O I
10.1016/j.chroma.2011.07.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional gas chromatography (GCxGC) is a powerful technology for separating complex samples. The typical goal of GCxGC peak detection is to aggregate data points of analyte peaks based on their retention times and intensities. Two techniques commonly used for two-dimensional peak detection are the two-step algorithm and the watershed algorithm. A recent study [4] compared the performance of the two-step and watershed algorithms for GCxGC data with retention-time shifts in the second-column separations. In that analysis, the peak retention-time shifts were corrected while applying the two-step algorithm but the watershed algorithm was applied without shift correction. The results indicated that the watershed algorithm has a higher probability of erroneously splitting a single two-dimensional peak than the two-step approach. This paper reconsiders the analysis by comparing peak-detection performance for resolved peaks after correcting retention-time shifts for both the two-step and watershed algorithms. Simulations with wide-ranging conditions indicate that when shift correction is employed with both algorithms, the watershed algorithm detects resolved peaks with greater accuracy than the two-step method. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:6792 / 6798
页数:7
相关论文
共 22 条
[1]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[2]  
Beucher S., 1992, SCANNING MICROSCOPY, P299
[3]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[4]  
Fraga CG, 2000, HRC-J HIGH RES CHROM, V23, P215
[5]   Increasing the number of analyzable peaks in comprehensive two dimensional separations through chemometrics [J].
Fraga, CG ;
Bruckner, CA ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :675-683
[6]   The chemometric resolution and quantification of overlapped peaks form comprehensive two-dimensional liquid chromatography [J].
Fraga, CG ;
Corley, CA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1096 (1-2) :40-49
[7]   Parallel factor analysis (PARAFAC) of target analytes in GC x GC-TOFMS data: Automated selection of a model with an appropriate number of factors [J].
Hoggard, Jamin C. ;
Synovec, Robert E. .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1611-1619
[8]   Deconvolution of overlapped peaks based on the exponentially modified Gaussian model in comprehensive two-dimensional gas chromatography [J].
Kong, HW ;
Ye, F ;
Lu, X ;
Guo, L ;
Tian, J ;
Xu, GW .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) :160-164
[9]   Development of an algorithm for peak detection in comprehensive two-dimensional chromatography [J].
Peters, Sonja ;
Vivo-Truyols, Gabriel ;
Marriott, Philip J. ;
Schoenmakers, Peter J. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) :14-24
[10]  
Prazen BJ, 1999, J MICROCOLUMN SEP, V11, P97, DOI 10.1002/(SICI)1520-667X(1999)11:2<97::AID-MCS2>3.0.CO