AimsVoiding dysfunction in adult men may be caused by bladder outlet obstruction (BOO) and/or detrusor underactivity (DU). Until now, it is only possible to classify BOO and DU by pressure-flow analysis. Low values of the maximum Watts factor (W-max) indicate DU but thresholds for the diagnosis have not been established. Purpose of this study was to construct a nomogram using bladder outlet resistance and detrusor contractility in order to classify BOO and DU simultaneously. MethodsTreatment naive men aged 40 years with uncomplicated lower urinary tract symptoms (LUTS) were prospectively evaluated. Patients were assessed with IPSS, prostate volume, uroflowmetry, post-void residual, and pressure-flow measurement. The bladder outlet obstruction index (BOOI) was used to determine BOO-grade and W-max to calculate detrusor contractility. Individual BOOI-W-max values were plotted in a graph. Linear interpolation was applied to determine the 10th, 25th, 50th, 75th, and 90th percentiles. ResultsRetrospective analysis of 822 male patients with means of 64 years, IPSS 16, and prostate volume of 40 cc. Patient and clinical parameters of the <25th percentile groups were significantly different compared to the 25th-50th percentiles: age (66 vs. 63 years, P=0.006), bladder capacity (503 vs. 442ml, P=0.009), post-void residual urine (167 vs. 116ml, P=0.001), and voiding efficiency (67% vs. 73%, P=0.015). ConclusionsThe nomogram quantifies the relationship between detrusor contractility and BOO in men with LUTS. A measurement value <25th percentile correlates with clinical indicators of DU and is proposed as a cut-off value for DU-diagnosis. Higher age, bladder capacity, and PVR as well as lower voiding efficiency indicate DU. Neurourol. Urodynam. 35:980-986, 2016. (c) 2015 Wiley Periodicals, Inc.