摘要
This research focuses on a new type of buckling-restrained brace (BRB) with replaceable steel angle fuses. The proposed BRB offers ease of postearthquake examination of fuse damage, convenient and prompt replacement of damaged fuses, and reuse of the buckling restraining elements. To investigate seismic behavior of the proposed BRB, seven brace specimens are tested. The test parameters varied in these specimens include fuse design, fuse material, debonding material, and loading protocol. Test results show that the proposed BRB can exhibit stable hysteretic behavior up to fairly high fuse strain levels. Failure modes of the specimens are found to be ruptures of the angle fuses, as expected. The compression strength adjustment factors and the cumulative plastic deformations of the specimens are found to satisfy the requirements specified by the current U.S. seismic design provisions for structural steel buildings. Moreover, the authors demonstrate that specimens repaired through fuse replacement remain satisfactory in following tests. Furthermore, rupture failures of the proposed BRB can be captured by the modified Park-Ang damage measure. (C) 2018 American Society of Civil Engineers.
引用
收藏
页数:14
相关论文
共 34 条
[1]   Ductility capacity models for buckling-restrained braces [J].
Andrews, Blake M. ;
Fahnestock, Larry A. ;
Song, Junho .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (8-9) :1712-1720
[2]  
Aniello M., 2014, The Open Construction and Building Technology Journal, V8, P216
[3]  
[Anonymous], 2016, 34116 AISC ANSIAISC
[4]   Cyclic Testing of a Buckling Restrained Braced Frame with Unconstrained Gusset Connections [J].
Berman, Jeffrey W. ;
Bruneau, Michel .
JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (12) :1499-1510
[5]  
Black C., 2002, Component Testing, Stability Analysis and Characterization of Buckling-Restrained Unbonded BracesTM
[6]   Design of steel frames equipped with BRBs in the framework of Eurocode 8 [J].
Bosco, M. ;
Marino, E. M. ;
Rossi, P. P. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 113 :43-57
[7]  
Brown A. P., 2001, MODERN STEEL CONSTR, V41, P29
[8]  
Bruneau M., 2011, Ductile design of steel structures, V2nd
[9]  
CSA (Canadian Standards Association), 2016, S1614 CSA CANCSA
[10]   Global Restraint in Ultra-Lightweight Buckling-Restrained Braces [J].
Dusicka, Peter ;
Tinker, John .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (01) :139-150