Flash Glucose Monitoring Can Accurately Reflect Postprandial Glucose Changes in Healthy Adults in Nutrition Studies

被引:6
作者
Wong, Tommy H. T. [1 ]
Wan, Jennifer M. F. [1 ]
Louie, Jimmy Chun Yu [1 ]
机构
[1] Univ Hong Kong, Sch Biol Sci, Pokfulam, Hong Kong, Peoples R China
关键词
adult; flash glucose monitoring system; postprandial glucose; capillary glucose; interstitial glucose; GLYCEMIC INDEX; INSULIN; BLOOD;
D O I
10.1080/07315724.2020.1734990
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: This study investigated the accuracy of a flash glucose monitoring system (FGMS) in a postprandial setting. Methods: Ten fasted adults without diabetes wore the FGMS sensors then consumed a standard breakfast. Their glucose levels were subsequently recorded for 2 hours, both by the FGMS and by measuring capillary glucose levels using the glucose oxidase method. The accuracy of the FGMS data was assessed using the accuracy limits stated in ISO 15197:2013. Results: FGMS measurements were mostly lower than glucose oxidase measurements (mean absolute relative difference +/- SD: 25.4 +/- 17.0%, p < 0.001). However, the maximum difference from baseline captured by the two methods was not significantly different (mean +/- SD, glucose oxidase: 58.5 +/- 18.9 mg/dl; FGMS, 54.4 +/- 28.9 mg/dl, p = 0.366). Conclusions: FGMS could track the incremental glycaemic excursions after meals in adults without diabetes, yet further studies with greater sample sizes are needed to confirm this finding.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 28 条
  • [11] Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose Monitoring
    El-Laboudi, Ahmed H.
    Godsland, Ian F.
    Johnston, Desmond G.
    Oliver, Nick S.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (12) : 806 - 812
  • [12] FOKKERT MJ, 2017, BMJ OPEN DIAB RES CA, V5, P320
  • [13] METABOLIC STUDIES FOLLOWING ORAL INGESTION OF DIFFERENT DOSES OF GLUCOSE
    FORSTER, H
    HASLBECK, M
    MEHNERT, H
    [J]. DIABETES, 1972, 21 (11) : 1102 - &
  • [14] Estimating plasma glucose with the FreeStyle Libre Pro continuous glucose monitor during oral glucose tolerance tests in youth without diabetes
    Ghane, Nejla
    Broadney, Miranda M.
    Davis, Elisabeth K.
    Trenschel, Robert W.
    Collins, Shavonne M.
    Brady, Sheila M.
    Yanovski, Jack A.
    [J]. PEDIATRIC DIABETES, 2019, 20 (08) : 1072 - 1079
  • [15] Kenneth Ward W, 2008, J Diabetes Sci Technol, V2, P768
  • [16] Correct homeostasis model assessment (HOMA) evaluation uses the computer program
    Levy, JC
    Matthews, DR
    Hermans, MP
    [J]. DIABETES CARE, 1998, 21 (12) : 2191 - 2192
  • [17] Toward Defining the Threshold Between Low and High Glucose Variability in Diabetes
    Monnier, Louis
    Colette, Claude
    Wojtusciszyn, Anne
    Dejager, Sylvie
    Renard, Eric
    Molinari, Nicolas
    Owens, David R.
    [J]. DIABETES CARE, 2017, 40 (07) : 832 - 838
  • [18] A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes
    Olafsdottir, Arndis F.
    Attvall, Stig
    Sandgren, Ulrika
    Dahlqvist, Sofia
    Pivodic, Aldina
    Skrtic, Stanko
    Theodorsson, Elvar
    Lind, Marcus
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (03) : 164 - 172
  • [19] Pfutzner Andreas, 2013, J Diabetes Sci Technol, V7, P1275
  • [20] Rebrin K, 2000, Diabetes Technol Ther, V2, P461, DOI 10.1089/15209150050194332