SCADA Data-Based Working Condition Classification for Condition Assessment of Wind Turbine Main Transmission System

被引:8
作者
Chen, Huanguo [1 ]
Xie, Chao [1 ]
Dai, Juchuan [2 ]
Cen, Enjie [3 ]
Li, Jianmin [1 ]
机构
[1] Zhejiang Sci Tech Univ, Fac Mech Engn & Automat, Hangzhou 310018, Peoples R China
[2] Hunan Univ Sci & Technol, Sch Mech Engn, Xiangtan 411201, Peoples R China
[3] Hangzhou Dingchuan Informat Technol Co Ltd, Hangzhou 310016, Peoples R China
关键词
main transmission system; working conditions classification; wind turbine working characteristics; alarm threshold; k-means clustering; SCADA data;
D O I
10.3390/en14217043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the complex and variable conditions under which wind turbines operate, existing working condition classification methods are inadequate for condition assessment of the main transmission system. Because working conditions are too few after classification, it cannot effectively describe the complex and variable working conditions of wind turbine. This can lead to high false-alarm rates in the condition monitoring, which affect normal operations. This paper proposes a working condition classification method for the main transmission system of wind turbines based on supervisory control and data acquisition (SCADA) data. Firstly, correlation analysis of SCADA data acquired by wind farm is used to select the parameters relevant to the main transmission system. Secondly, according to the wind turbine control principle, the working conditions are initially divided into four phases: shutdown, start-up, maximum wind energy tracking, and constant speed. The k-means clustering algorithm is used to subdivide the maximum wind energy-tracking phase and constant speed phase, which account for a larger proportion of the working conditions, to achieve better classification. Finally, a case study is used to demonstrate the calculation of alarm thresholds and alarm rates for each working condition. The results are compared with the direct use of k-means clustering for working condition classification. It is concluded that the proposed method can significantly reduce the false-alarm rate of the vibration detection process.
引用
收藏
页数:18
相关论文
共 36 条
[1]   Multivariate Analysis Applied to Aquifer Hydrogeochemical Evaluation: A Case Study in the Coastal Significant Subterranean Water Body between "Cecina River and San Vincenzo", Tuscany (Italy) [J].
Bastianoni, Alessia ;
Guastaldi, Enrico ;
Barbagli, Alessio ;
Bernardinetti, Stefano ;
Zirulia, Andrea ;
Brancale, Mariantonietta ;
Colonna, Tommaso .
APPLIED SCIENCES-BASEL, 2021, 11 (16)
[2]  
Cao H.R., 2020, SHIP SCI TECHNOL, V42, P103
[3]   Anomaly detection and critical attributes identification for products with multiple operating conditions based on isolation forest [J].
Chen, Hansi ;
Ma, Hongzhan ;
Chu, Xuening ;
Xue, Deyi .
ADVANCED ENGINEERING INFORMATICS, 2020, 46
[4]  
Cheng H.F., 2019, P 6 CHIN WIND POW MA
[5]   Investigation of energy output in mountain wind farm using multiple-units SCADA data [J].
Dai, Juchuan ;
Tan, Yayi ;
Shen, Xiangbin .
APPLIED ENERGY, 2019, 239 :225-238
[6]   Ageing assessment of a wind turbine over time by interpreting wind farm SCADA data [J].
Dai, Juchuan ;
Yang, Wenxian ;
Cao, Junwei ;
Liu, Deshun ;
Long, Xing .
RENEWABLE ENERGY, 2018, 116 :199-208
[7]  
Dong HY, 2017, CHIN CONT DECIS CONF, P6983, DOI 10.1109/CCDC.2017.7978440
[8]  
Gu Yujiong, 2014, Electric Power Science and Engineering, V30, P1, DOI 10.3969/j.issn.1672-0792.2014.08.001
[9]  
Guo Z.H.A.O., 2021, COMPUTER KNOWLEDGE T, V17, P9
[10]  
Han D.P., 2019, THESIS N CHINA ELECT