Study on the use of gonadal protection shields during paediatric pelvic X-rays

被引:23
作者
Sikand, M [1 ]
Stinchcombe, S [1 ]
Livesley, PJ [1 ]
机构
[1] Kings Mill Hosp, Sutton NG17 4JL, Notts, England
关键词
X-ray; gonad; paediatrics;
D O I
10.1308/003588403322520852
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: There are national guidelines issued by all hospital radiology departments concerning the use of gonadal protection shields for taking X-rays of the pelvis. It is important to follow these guidelines especially when paediatric X-rays are taken. Gonads are very susceptible to radiation as they fall directly in the line of radiation exposure when pelvic X-rays are taken. Aim: To examine whether these guidelines were being followed. Methods: This audit considered 355 radiographs taken in a 6-month period on 149 patients, under the age of 16 years, attending the orthopaedic department at King's Mill Hospital. Results: In only 23% of the cases studied, the correct use of gonad protection shields had been performed. In 67% of the unprotected patients, the shields were not used at all. In the remainder, the shield was incorrectly applied. Out of all the patients, 45% had more than one X-ray thus exposing the gonads to unnecessary radiation. In addition, 8% of patients had a CT scan, 6% had fluoroscopy and 42% had radiographs of other regions of the body. Conclusions: Guidelines should be adhered to as far as possible and efforts always be made to decrease radiation exposure. Application of the current guidelines excludes the first X-ray exposure of the female pelvis and of the pelvis of trauma patients from the use of shields, thus adding to the number of the X-rays done without protection.
引用
收藏
页码:422 / 425
页数:4
相关论文
共 26 条
  • [21] Experimental study on hard x-rays emitted from metre-scale negative discharges in air
    Kochkin, P. O.
    van Deursen, A. P. J.
    Ebert, U.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2015, 48 (02)
  • [22] Prevalence of subclinical axial involvement in patients diagnosed with peripheral psoriatic arthritis on X-rays: A single-centre retrospective study
    Mizukawa, Itsumi
    Kamata, Masahiro
    Yamamoto, Asako
    Tada, Yayoi
    EXPERIMENTAL DERMATOLOGY, 2023, 32 (12) : 2180 - 2182
  • [23] Anti-tumor Effect of High Doses of Carbon Ions and X-Rays during Irradiation of Ehrlich Ascites Carcinoma Cells Ex Vivo
    V. E. Balakin
    T. A. Belyakova
    O. M. Rozanova
    E. N. Smirnova
    N. S. Strelnikova
    E. A. Kuznetsova
    Doklady Biochemistry and Biophysics, 2023, 513 : S30 - S35
  • [24] Anti-tumor Effect of High Doses of Carbon Ions and X-Rays during Irradiation of Ehrlich Ascites Carcinoma Cells Ex Vivo
    Balakin, V. E.
    Belyakova, T. A.
    Rozanova, O. M.
    Smirnova, E. N.
    Strelnikova, N. S.
    Kuznetsova, E. A.
    DOKLADY BIOCHEMISTRY AND BIOPHYSICS, 2023, 513 (SUPPL 1) : S30 - S35
  • [25] Ikaros is a critical target during simultaneous exposure to X-rays and N-ethyl-N-nitrosourea in mouse T-cell lymphomagenesis
    Hirano, Shinobu
    Kakinuma, Shizuko
    Amasaki, Yoshiko
    Nishimura, Mayumi
    Imaoka, Tatsuhiko
    Fujimoto, Shinji
    Hino, Okio
    Shimada, Yoshiya
    INTERNATIONAL JOURNAL OF CANCER, 2013, 132 (02) : 259 - 268
  • [26] Novel AI-Based Algorithm for the Automated Computation of Coronal Parameters in Adolescent Idiopathic Scoliosis Patients: A Validation Study on 100 Preoperative Full Spine X-Rays
    Berlin, Clara
    Adomeit, Sonja
    Grover, Priyanka
    Dreischarf, Marcel
    Halm, Henry
    Duerr, Oliver
    Obid, Peter
    GLOBAL SPINE JOURNAL, 2024, 14 (06) : 1728 - 1737