Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters

被引:79
作者
Chiu, Asher [1 ]
Chen, Yen-Wei [1 ]
Hayashi, Juri [1 ]
Sadr, Alireza [1 ]
机构
[1] Univ Washington, Dept Restorat Dent, Sch Dent, Seattle, WA 98195 USA
关键词
digital impression; CAD; CAM; accuracy; intraoral scanner; high resolution; CONVENTIONAL IMPRESSIONS; PRECISION;
D O I
10.3390/s20041157
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The advancement of intraoral scanners has allowed for more efficient workflow in the dental clinical setting. However, limited data exist regarding the accuracy of the digital impressions produced with various scanner settings and scanning approaches. The purpose of this in vitro study was to compare the accuracy of digital impressions at the crown preparation margin using different scanning resolutions of a specific intraoral scanner system. An all-ceramic crown preparation of a mandibular first molar was constructed in a typodont, and a scan (n = 3) was created with an industrial-grade laboratory scanner (3Shape D2000) as the control. Digital impressions were obtained with an intraoral scanner (3Shape TRIOS 3) under three settings-high resolution (HR), standard resolution (SR), and combined resolution (SHR). Comparative 3D analysis of scans was performed with Geomagic Control X software to measure the discrepancy between intraoral scans and the control scan along the preparation finish line. The scan time and number of images captured per scan were recorded. Statistical analysis was performed by one-way ANOVA, two-way repeated measures ANOVA, Pearson's correlation, and Dunnett's T3 test (alpha = 0.05). Significant differences were observed for scan time and for number of images captured among scan resolution settings (alpha < 0.05). The scan time for the SR group was, on average, 34.2 s less than the SHR group and 46.5 s less than the HR group. For discrepancy on the finish line, no significant differences were observed among scanning resolutions (HR: 31.5 +/- 5.5 mu m, SHR: 33.2 +/- 3.7 mu m, SR: 33.6 +/- 3.1 mu m). Significant differences in discrepancy were observed among tooth surfaces, with the distal surface showing the highest discrepancies. In conclusion, the resolution of the intra-oral scanner is primarily defined by the system hardware and optimized for default scans. A software high-resolution mode that obtains more data over a longer time may not necessarily benefit the scan accuracy, while the tooth preparation and surface parameters do affect the accuracy.
引用
收藏
页数:9
相关论文
共 22 条
[1]   Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review [J].
Ahlholm, Pekka ;
Sipila, Kirsi ;
Vallittu, Pekka ;
Jakonen, Minna ;
Kotiranta, Ulla .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01) :35-41
[2]   A novel in vivo method to evaluate trueness of digital impressions [J].
Albdour, Emad A. ;
Shaheen, Eman ;
Vranckx, Myrthel ;
Mangano, Francesco Guido ;
Politis, Constantinus ;
Jacobs, Reinhilde .
BMC ORAL HEALTH, 2018, 18
[3]   MARGINAL ADAPTATION OF THREE DIFFERENT ZIRCONIUM DIOXIDE THREE-UNIT FIXED DENTAL PROSTHESES [J].
Att, Wael ;
Komine, Futoshii ;
Gerds, Thomas ;
Strub, Joerg Rudolf .
JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (04) :239-247
[4]   Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients [J].
Boeddinghaus, Moritz ;
Breloer, Eva Sabina ;
Rehmann, Peter ;
Woestmann, Bernd .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) :2027-2034
[5]   Analysis on the Accuracy of Intraoral Scanners: The Effects of Mandibular Anterior Interdental Space [J].
Chun, Ji-hye ;
Tahk, Ji Hyun ;
Chun, Youn-Sic ;
Park, Ji-Man ;
Kim, Minji .
APPLIED SCIENCES-BASEL, 2017, 7 (07)
[6]   In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions [J].
Ender, Andreas ;
Attin, Thomas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (03) :313-320
[7]  
Hack G., 2015, ADA PROFESSIONAL PRO, V10, P1
[8]   Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study [J].
Mangano, Francesco G. ;
Veronesi, Giovanni ;
Hauschild, Uli ;
Mijiritsky, Eitan ;
Mangano, Carlo .
PLOS ONE, 2016, 11 (09)
[9]   Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch [J].
Medina-Sotomayor, Priscilla ;
Pascual-Moscardo, Agustin ;
Camps, Isabel .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (05) :811-820
[10]   Accuracy of four digital scanners according to scanning strategy in complete-arch impressions [J].
Medina-Sotomayor, Priscilla ;
Pascual M., Agustin ;
Camps A., Isabel .
PLOS ONE, 2018, 13 (09)