Experimental heat transfer and friction in channels roughened with angled, V-shaped, and discrete ribs on two opposite walls

被引:229
作者
Taslim, ME [1 ]
Li, T [1 ]
Kercher, DM [1 ]
机构
[1] GE CO, AIRCRAFT ENGINES, LYNN, MA 01910 USA
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 1996年 / 118卷 / 01期
关键词
D O I
10.1115/1.2836602
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Experimental investigations have shown that the enhancement in heat transfer coefficients for airflow in a channel roughened with angled ribs is on the average higher than that roughened with 90 deg ribs of the same geometry. Secondary flows generated by the angled ribs are believed to be responsible for these higher heat transfer coefficients. These secondary flows also create a spanwise variation in heat transfer coefficient on the roughened wall with high levels of heat transfer coefficient at one end of the rib and low levels at the other end. In an effort basically to double the area of high heat transfer coefficients, the angled rib is broken at the center to form a V-shaped rib, and tears are conducted to investigate the resulting heat transfer coefficients and friction factors. Three different square rib geometries, corresponding to blockage ratios of 0.083, 0.125, and 0.167, with a fixed pitch-to-height ratio of 10, mounted on two opposite walls of a square channel in a staggered configuration, are tested in a stationary channel for 5000 < Re < 30,000. Heat transfer coefficients, friction factors, and thermal performances are compared with those of 90 deg, 45 deg, and discrete angled ribs. The V-shaped ribs are tested for both pointing upstream and downstream of the main pow. Test results show that: (a) 90 deg ribs represent the lowest thermal performance, based on the same pumping power and is essentially the same for the 2:1 change in blockage ratio, (b) low-blockage-ratio (e/D-h = 0.083) V-shaped ribs pointing downstream produced the highest heat transfer enhancement and friction factors, Among all other geometries with blockage ratios of 0.125 and 0.167, 45 deg ribs showed the highest heat transfer enhancements with friction factors less than those of V-shaped ribs, (c) thermal performance of 45 deg ribs and the lowest blockage discrete ribs are among the highest of the geometries tested in this investigation, and (d) discrete angled ribs, although inferior to 45 deg and V-shaped ribs, produce much higher heat transfer coefficients and lower friction factors compared to 90 deg ribs.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 29 条
  • [1] ABUAF N, 1986, 8 INT HEAT TRANSF C, P2837
  • [2] [Anonymous], AUGMENTATION CONVECT
  • [3] CHANDRA PR, 1989, AIAA J THERMOPHYSICS, V3, P315
  • [4] CHANDRA PR, 1988, ASME, V110, P233
  • [5] Colburn AP, 1933, T AM INST CHEM ENG, V29, P174
  • [6] Dittus F.W., 1930, University of California Publications in Engineering, V2, P443, DOI [10.1016/0735-1933(85)90003-X, DOI 10.1016/0735-1933(85)90003-X]
  • [7] ELHUSAYNI H, 1991, THESIS NE U BOST MA
  • [8] EXPERIMENTAL HEAT-TRANSFER INVESTIGATION OF STATIONARY AND ORTHOGONALLY ROTATING ASYMMETRIC AND SYMMETRICAL HEATED SMOOTH AND TURBULATED CHANNELS
    ELHUSAYNI, HA
    TASLIM, ME
    KERCHER, DM
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1994, 116 (01): : 124 - 132
  • [9] LOCAL HEAT-TRANSFER IN A ROTATING SERPENTINE PASSAGE WITH RIB-ROUGHENED SURFACES
    FANN, S
    YANG, WJ
    ZHANG, NL
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (02) : 217 - 228
  • [10] AUGMENTED HEAT-TRANSFER IN SQUARE CHANNELS WITH PARALLEL, CROSSED, AND V-SHAPED ANGLED RIBS
    HAN, JC
    ZHANG, YM
    LEE, CP
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1991, 113 (03): : 590 - 596