Biomechanical and histomorphometric study of the bone-screw interface of calcium pyrophosphate coated titanium screws

被引:0
|
作者
Lee, JH
Ryu, HS
Lee, DS
Hong, KS
Chang, BS
Lee, CK
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul 110744, South Korea
[2] Gachon Med Sch, Dept Orthopaed Surg, Inchon 405760, South Korea
[3] Seoul Natl Univ, Coll Engn, Sch Mat Sci & Engn, Seoul 151742, South Korea
来源
BIOCERAMICS 17 | 2005年 / 284-286卷
关键词
biomechanical; bone-screw interface; calcium pyrophosphate; coating; histomorphometry; TI-BASED IMPLANTS; GLASS COATINGS; HYDROXYAPATITE;
D O I
10.4028/www.scientific.net/KEM.284-286.219
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The purpose of this study is to compare the osseointegration of calcium pyrophosphate(CPP) coated screws with uncoated screws. CPP coating was prepared and coated by dipping method. CPP coated and uncoated screws were inserted into the mongrel dogs. The insertion torques, radiographs, histology, histomorphometric analysis, and extraction torques were evaluated at 2, 4, and 8 weeks after surgery. The insertion torque was not different between CPP coated and uncoated screws. The extraction torques of CPP coated screws at 2, 4, and 8 weeks(5.45 +/- 2.05, 7.62 +/- 1.51 and 6.60 +/- 2.80 cNM) were significantly higher than their insertion torques(2.74 +/- 1.13, 2.98 +/- 0.70, and 2.18 +/- 1.34 cNM)(p < 0.0001, < 0.0001 and 0.0005 respectively) and significantly higher than the extraction torques of uncoated screws(1.14 +/- 0.470, 2.57 +/- 1.36, and 3.18 +/- 0.499 cNM). The percentages of direct bone-screw contact of CPP coated screws were statistically higher than those of uncoated screws at 2, 4, and 8 weeks. These results suggest that CPP coating may improve the clinical results by allowing early motion exercises and early weight bearing.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 50 条
  • [31] Effect of pilot hole on biomechanical and in vivo pedicle screw–bone interface
    Patrícia Silva
    Rodrigo César Rosa
    Antonio Carlos Shimano
    Helton L. A. Defino
    European Spine Journal, 2013, 22 : 1829 - 1836
  • [32] Biomechanical comparison of bone-screw-fasteners versus traditional locked screws in plating female geriatric bone
    DeBaun, Malcolm R.
    Swinford, Steven T.
    Chen, Michael J.
    Thio, Timothy
    Behn, Anthony A.
    Lucas, Justin F.
    Bishop, Julius A.
    Gardner, Michael J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (02): : 193 - 198
  • [33] Histomorphometric Analysis of HA-Coated Implants Interface With Irradiated and Nonirradiated Bone
    Vidigal, Guaracilei Maciel, Jr.
    Crispino, Andrea Ferreira
    Groisman, Mario
    Soares, Glorio de Almeida
    IMPLANT DENTISTRY, 2008, 17 (04) : 414 - 421
  • [34] Biomechanical comparison of the screw-bone interface: Optimization of 1 and 2 screw constructs by varying screw diameter
    Mohamad, Fazir
    Oka, Richard
    Mahar, Andrew
    Wedemeyer, Michelle
    Newton, Peter
    SPINE, 2006, 31 (16) : E535 - E539
  • [35] BIOMECHANICAL STUDY OF THE SACROILIAC FRACTURE FIXATION WITH TITANIUM RODS AND PEDICLE SCREWS
    Ueno, Fabricio Hidetoshi
    Pisani, Marina Justi
    Machado, Andre Nunes
    Rodrigues, Fabio Lucas
    Fujiki, Edison Noburo
    Reis Rodrigues, Luciano Miller
    ACTA ORTOPEDICA BRASILEIRA, 2015, 23 (03): : 154 - 157
  • [36] Histomorphometric analysis of bone tissue repair in rabbits after insertion of titanium screws under different torque
    Togni, Fabricio
    Baras, Fabiola
    Ribas, Marina de Oliveira
    Taha, Murched Omar
    ACTA CIRURGICA BRASILEIRA, 2011, 26 (04) : 261 - 266
  • [37] Displaced femoral neck fractures at the bone-screw interface after in situ fixation of slipped capital femoral epiphysis
    Canale, ST
    Casillas, M
    Banta, JV
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) : 212 - 215
  • [38] Porous titanium-coated polyetheretherketone implants exhibit an improved bone-implant interface: an in vitro and in vivo biochemical, biomechanical, and histological study
    Cheng, Boyle C.
    Koduri, Sravanthi
    Wing, Charles A.
    Woolery, Natalie
    Cook, Daniel J.
    Spiro, Robert C.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2018, 11 : 391 - 402
  • [39] Biomechanical study of expandable pedicle screw fixation in severe osteoporotic bone comparing with conventional and cement-augmented pedicle screws
    Chen, Yi-Long
    Chen, Wen-Chuan
    Chou, Chi-Wei
    Chen, Jou-Wen
    Chang, Chia-Ming
    Lai, Yu-Shu
    Cheng, Cheng-Kung
    Wang, Shih-Tien
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (11) : 1416 - 1420
  • [40] Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface
    Silva, Patricia
    Rosa, Rodrigo Cesar
    Shimano, Antonio Carlos
    Defino, Helton L. A.
    EUROPEAN SPINE JOURNAL, 2013, 22 (08) : 1829 - 1836