Biomechanical and histomorphometric study of the bone-screw interface of calcium pyrophosphate coated titanium screws

被引:0
|
作者
Lee, JH
Ryu, HS
Lee, DS
Hong, KS
Chang, BS
Lee, CK
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul 110744, South Korea
[2] Gachon Med Sch, Dept Orthopaed Surg, Inchon 405760, South Korea
[3] Seoul Natl Univ, Coll Engn, Sch Mat Sci & Engn, Seoul 151742, South Korea
来源
BIOCERAMICS 17 | 2005年 / 284-286卷
关键词
biomechanical; bone-screw interface; calcium pyrophosphate; coating; histomorphometry; TI-BASED IMPLANTS; GLASS COATINGS; HYDROXYAPATITE;
D O I
10.4028/www.scientific.net/KEM.284-286.219
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The purpose of this study is to compare the osseointegration of calcium pyrophosphate(CPP) coated screws with uncoated screws. CPP coating was prepared and coated by dipping method. CPP coated and uncoated screws were inserted into the mongrel dogs. The insertion torques, radiographs, histology, histomorphometric analysis, and extraction torques were evaluated at 2, 4, and 8 weeks after surgery. The insertion torque was not different between CPP coated and uncoated screws. The extraction torques of CPP coated screws at 2, 4, and 8 weeks(5.45 +/- 2.05, 7.62 +/- 1.51 and 6.60 +/- 2.80 cNM) were significantly higher than their insertion torques(2.74 +/- 1.13, 2.98 +/- 0.70, and 2.18 +/- 1.34 cNM)(p < 0.0001, < 0.0001 and 0.0005 respectively) and significantly higher than the extraction torques of uncoated screws(1.14 +/- 0.470, 2.57 +/- 1.36, and 3.18 +/- 0.499 cNM). The percentages of direct bone-screw contact of CPP coated screws were statistically higher than those of uncoated screws at 2, 4, and 8 weeks. These results suggest that CPP coating may improve the clinical results by allowing early motion exercises and early weight bearing.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 50 条
  • [1] Biomechanical and histomorphometric study on the bone-screw interface of bioactive ceramic-coated titanium screws
    Lee, JH
    Ryu, HS
    Lee, DS
    Hong, KS
    Chang, BS
    Lee, CK
    BIOMATERIALS, 2005, 26 (16) : 3249 - 3257
  • [2] Improvement of the bone-screw interface strength with hydroxyapatite-coated and titanium-coated AO/ASIF cortical screws
    Moroni, A
    Faldini, C
    Rocca, M
    Stea, S
    Giannini, S
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (04) : 257 - 263
  • [3] A BIOMECHANICAL STUDY OF SHEAR LOAD ON BONE-SCREW INTERFACE OF THORACOLUMBAR VERTEBRAE
    Wang, Jiang-Ze
    Zhang, Feng
    You, Ming-Liang
    Sha, Mo
    Liang, Bo-Wei
    Liang, Dong-Zhu
    Ding, Zhen-Qi
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (06)
  • [4] Improved bone-screw interface with hydroxyapatite coating -: An in vivo study of loaded pedicle screws in sheep
    Sandén, B
    Olerud, C
    Johansson, C
    Larsson, S
    SPINE, 2001, 26 (24) : 2673 - 2678
  • [5] Biological assessment of the bone-screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in the osteopenic sheep
    Fini, M
    Giavaresi, G
    Greggi, T
    Martini, L
    Aldini, NN
    Parisini, P
    Giardino, R
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) : 176 - 183
  • [6] Remodeling along the bone-screw interface
    Praeger, Thomas Michael
    Mischkowski, Robert
    Laube, Nico
    Jost-Brinkmann, Paul-Georg
    Mueller-Hartwich, Ralf
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (05): : 337 - 348
  • [7] Axial cyclic behavior of the bone-screw interface
    Inceoglu, Serkan
    Ehlert, Mike
    Akbay, Atilla
    McLain, Robert F.
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (09) : 888 - 893
  • [8] Alendronate inhibits bone resorption at the bone-screw interface
    Miyaji, T
    Nakase, T
    Azuma, Y
    Shimizu, N
    Uchiyama, Y
    Yoshikawa, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 195 - 201
  • [9] Oxidized titanium screws coated with calcium ions and their performance in rabbit bone
    Sul, YT
    Johansson, CB
    Albrektsson, T
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (05) : 625 - 634
  • [10] The radiographic classification of the bone-screw interface in paediatric tibial lengthening
    McAndrew, Andrew R.
    Saleh, Michael
    Rigby, Alan S.
    Donnan, Leo T.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2007, 16 (05): : 305 - 311