Multidetector CT in patients suspected of having lumbar disk herniation: Comparison of standard-dose and simulated low-dose techniques

被引:20
|
作者
Bohy, Pascale
de Maertelaer, Viviane
Roquigny, Aymeric
Keyzer, Caroline
Tack, Denis
Gevenois, Pierre Alain
机构
[1] Univ Libre Bruxelles, Hop Erasme, Dept Radiol, B-1070 Brussels, Belgium
[2] Reseau Hosp Med Sociale, Dept Radiol, Baudour, Belgium
[3] Univ Charleroi, Ctr Hosp, Dept Radiol, Charleroi, Belgium
[4] Univ Libre Bruxelles, Inst Rech Interdisciplinaire Biol Humaine & Mol, Brussels, Belgium
关键词
D O I
10.1148/radiol.2442060606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare standard-dose and simulated low- dose multidetector computed tomography (CT) in patients suspected of having lumbar disk herniation. Materials and Methods: The institutional review board approved the research protocol with a waiver of patient informed consent. Sixty consecutive patients underwent multidetector CT with four detector rows at 1 mm collimation at 140 kVp, with tube current-time product adapted to body mass index (BMI): 200 ( BMI < 22 kg/ m2), 300 (BMI >= 22 to < 30 kg/ m2), and 400 effective mAs (BMI >= 30 kg/ m2). Simulated doses at 65%, 50%, 35%, and 20% of the dose were used for acquisition. During two separate sessions, three independent radiologists coded each of three caudal disks as normal, bulging, or herniated and graded canal and foramen compromise. Median numbers of discrepancies between the standard and reduced doses were compared with Friedman and Wilcoxon tests. Agreements within and between readers were evaluated through kappa statistics. Results: Dose reduction had no effect on a reader's ability to identify bulging disks (P =.128) and left and right foramen compromises (P =.413 and.665, respectively). However, for normal disks (P =.002), herniated disks (P =.004), and canal compromise (P =.002), dose reduction did have a significant effect. For normal disks and canal compromise, a reduction dose effect was not detected at 65% (P =.121 and .250, respectively) but appeared at 50% (P =.004 and .008, respectively). For herniation, a dose reduction effect was detected at 35% (P =.031). Agreements within and between readers ranged from poor to excellent and tended to decrease with dose reduction. Conclusion: For patients suspected of having lumbar disk herniation, tube charge settings could be reduced to 65% of the standard dose adapted to the BMI.
引用
收藏
页码:524 / 531
页数:8
相关论文
共 50 条
  • [1] Comparison between low-dose and standard-dose multidetector CT in patients with suspected chronic sinusitis
    Tack, D
    Widelec, J
    De Maertelaer, V
    Bailly, JM
    Delcour, C
    Gevenois, PA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) : 939 - 944
  • [2] Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma
    Mulkens, T. H.
    Marchal, P.
    Daineffe, S.
    Salgado, R.
    Bellinck, P.
    te Rijdt, B.
    Kegelaers, B.
    Termote, J-L
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (08) : 1444 - 1450
  • [3] Air trapping: Comparison of standard-dose and simulated low-dose thin-section CT techniques
    Bankier, Alexander A.
    Schaefer-Prokop, Cornelia
    De Maertelaer, Viviane
    Tack, Denis
    Jaksch, Peter
    Klepetko, Walter
    Gevenois, Pierre Alain
    RADIOLOGY, 2007, 242 (03) : 898 - 906
  • [4] Multi-detector row CT pulmonary angiography: Comparison of standard-dose and simulated low-dose techniques
    Tack, D
    De Maertelaer, V
    Petit, W
    Scillia, P
    Muller, P
    Suess, C
    Gevenois, PA
    RADIOLOGY, 2005, 236 (01) : 318 - 325
  • [5] CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT
    Christe, Andreas
    Lin, Margaret C.
    Yen, Andrew C.
    Hallett, Rich L.
    Roychoudhury, Kingshuk
    Schmitzberger, Florian
    Fleischmann, Dominik
    Leung, Ann N.
    Rubin, Geoffry D.
    Vock, Peter
    Roos, Justus E.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2860 - 2866
  • [6] Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic
    Poletti, Pierre-Alexandre
    Platon, Alexandra
    Rutschmann, Olivier T.
    Schmidlin, Franz R.
    Iselin, Christophe E.
    Becker, Christoph D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (04) : 927 - 933
  • [7] Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT
    Lee, Sun Hwa
    Yun, Seong Jong
    Kim, Dong Hyeon
    Jo, Hyeon Hwan
    Song, Jae Gwang
    Park, Yong Sung
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1077):
  • [8] Dynamic expiratory volumetric CT imaging of the central airways: Comparison of standard-dose and low-dose techniques
    Zhang, JB
    Hasegawa, I
    Feller-Kopman, D
    Boiselle, PM
    ACADEMIC RADIOLOGY, 2003, 10 (07) : 719 - 724
  • [9] Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    Nevzat Karabulut
    Mustafa Törü
    Veli Gelebek
    Meltem Gülsün
    Macit O. Ariyürek
    European Radiology, 2002, 12 : 2764 - 2769
  • [10] Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    Karabulut, N
    Törü, M
    Gelebek, V
    Gülsün, M
    Ariyurek, OM
    EUROPEAN RADIOLOGY, 2002, 12 (11) : 2764 - 2769