DEVELOPMENTS IN MOLECULAR SIMS DEPTH PROFILING AND 3D IMAGING OF BIOLOGICAL SYSTEMS USING POLYATOMIC PRIMARY IONS

被引:119
作者
Fletcher, John S. [1 ]
Lockyer, Nicholas P. [1 ]
Vickerman, John C. [1 ]
机构
[1] Univ Manchester, Manchester Interdisciplinary Bioctr, Sch Chem Engn & Analyt Sci, Manchester M60 1QD, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
SIMS; mass spectral imaging; molecular depth profiling; single cells; tissue; MASS-SPECTROMETRY; TOF-SIMS; THIN-FILMS; C-60; BOMBARDMENT; EMISSION; SUPPRESSION; MODEL; IONIZATION; DESORPTION;
D O I
10.1002/mas.20275
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In principle mass spectral imaging has enormous potential for discovery applications in biology. The chemical specificity of mass spectrometry combined with spatial analysis capabilities of liquid metal cluster beams and the high yields of polyatomic ion beams should present unprecedented ability to spatially locate molecular chemistry in the 100 nm range. However, although metal cluster ion beams have greatly increased yields in the m/z range up to 1000, they still have to be operated under the static limit and even in most favorable cases maximum yields for molecular species from 1 mm pixels are frequently below 20 counts. However, some very impressive molecular imaging analysis has been accomplished under these conditions. Nevertheless although molecular ions of lipids have been detected and correlation with biology is obtained, signal levels are such that lateral resolution must be sacrificed to provide a sufficient signal to image. To obtain useful spatial resolution detection below 1 mm is almost impossible. Too few ions are generated! The review shows that the application of polyatomic primary ions with their low damage cross-sections offers hope of a new approach to molecular SIMS imaging by accessing voxels rather than pixels to thereby increase the dynamic signal range in 2D imaging and to extend the analysis to depth profiling and 3D imaging. Recent data on cells and tissue analysis suggest that there is, in consequence, the prospect that a wider chemistry might be accessible within a sub-micron area and as a function of depth. However, these advances are compromised by the pulsed nature of current ToF-SIMS instruments. The duty cycle is very low and results in excessive analysis times, and maximum mass resolution is incompatible with maximum spatial resolution. New instrumental directions are described that enable a dc primary beam to be used that promises to be able to take full advantage of all the capabilities of the polyatomic ion beam. Some new data are presented that suggest that the aspirations for these new instruments will be realized. However, although prospects are good, the review highlights the continuing challenges presented by the low ionization efficiency and the complications that arise from matrix effects. (C) 2010 Wiley Periodicals, Inc., Mass Spec Rev 30:142-174, 2011
引用
收藏
页码:142 / 174
页数:33
相关论文
共 95 条
[11]   C60 Secondary Ion Mass Spectrometry with a Hybrid-Quadrupole Orthogonal Time-of-Flight Mass Spectrometer [J].
Carado, Anthony ;
Passarelli, M. K. ;
Kozole, Joseph ;
Wingate, J. E. ;
Winograd, Nicholas ;
Loboda, A. V. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :7921-7929
[12]   Subcellular imaging by dynamic SIMS ion microscopy [J].
Chandra, S ;
Smith, DR ;
Morrison, GH .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :104A-114A
[13]   Molecular depth profiling with cluster ion beams [J].
Cheng, J ;
Wucher, A ;
Winograd, N .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (16) :8329-8336
[14]   Depth profiling of peptide films with TOF-SIMS and a C60 probe [J].
Cheng, J ;
Winograd, N .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :3651-3659
[15]   Direct comparison of Au+3 and C+60 cluster projectiles in SIMS molecular depth profiling [J].
Cheng, Juan ;
Kozole, Joseph ;
Hengstebeck, Robert ;
Winograd, Nicholas .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (03) :406-412
[16]   Is proton cationization promoted by polyatomic primary ion bombardment during time-of-flight secondary ion mass spectrometry analysis of frozen aqueous solutions? [J].
Conlan, XA ;
Lockyer, NP ;
Vickerman, JC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (08) :1327-1334
[17]  
CORNETT DS, 1994, RAPID COMMUN MASS SP, V8, P996
[18]   Development and experimental application of a gold liquid metal ion source [J].
Davies, N ;
Weibel, DE ;
Blenkinsopp, P ;
Lockyer, N ;
Hill, R ;
Vickerman, JC .
APPLIED SURFACE SCIENCE, 2003, 203 :223-227
[19]   Attempts for molecular depth profiling directly on a rat brain tissue section using fullerene and bismuth cluster ion beams [J].
Debois, Delphine ;
Brunelle, Alain ;
Laprevote, Olivier .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 260 (2-3) :115-120
[20]   In Situ Lipidomic Analysis of Nonalcoholic Fatty Liver by Cluster TOF-SIMS Imaging [J].
Debois, Delphine ;