The between-day and inter-rater reliability of a novel wireless system to analyse lumbar spine posture

被引:23
|
作者
O'Sullivan, Kieran [1 ]
Galeotti, Luciana [1 ,2 ]
Dankaerts, Wim [2 ,3 ]
O'Sullivan, Leonard [1 ]
O'Sullivan, Peter [4 ]
机构
[1] Univ Limerick, Limerick, Ireland
[2] Catholic Univ, Louvain, Belgium
[3] Univ Coll Limburg, Hasselt, Belgium
[4] Curtin Univ Technol, Perth, WA, Australia
关键词
back pain; posture; reliability; LOW-BACK-PAIN; TRUNK MUSCLE ACTIVATION; SITTING POSTURES; 3-DIMENSIONAL MEASUREMENT; HEALTHY CONTROLS; MOVEMENT; CLASSIFICATION; CURVATURE; MOTION; IMPAIRMENT;
D O I
10.1080/00140139.2010.535020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Lumbar posture is commonly assessed in non-specific chronic low back pain (NSCLBP), although quantitative measures have mostly been limited to laboratory environments. The BodyGuard is a spinal position monitoring device that can monitor posture in real time, both inside and outside the laboratory. The reliability of this wireless device was examined in 18 healthy participants during usual sitting and forward bending, two tasks that are commonly provocative in NSCLBP. Reliability was determined using intraclass correlation coefficients (ICC), the standard error of measurement (SEM), the mean difference and the minimal detectable change (MDC90). Between-day ICC values ranged from 0.84 to 0.87, with small SEM (5%), mean difference (9%) and MDC90 (14%) values. Inter-rater ICC values ranged from 0.91 to 0.94, with small SEM (4%), mean difference (6%) and MDC90 (9%) values. Between-day and inter-rater reliability are essential requirements for clinical utility and were excellent in this study. Further studies into the validity of this device and its application in clinical trials in occupational settings are required. Statement of Relevance:A novel device that can analyse spinal posture exposure in occupational settings in a minimally invasive manner has been developed. This study established that the device has excellent between-day and inter-rater reliability in healthy pain-free subjects. Further studies in people with low back pain are planned.
引用
收藏
页码:82 / 90
页数:9
相关论文
共 50 条
  • [41] Intra-rater and inter-rater reliability of neutral and target lumbar positioning tests in subjects with and without non-specific lower back pain
    Reddy, Ravi Shankar
    Alahmari, Khalid A.
    Samuel, Paul Silvian
    Tedla, Jaya Shanker
    Kakaraparthi, Venkata Nagaraj
    Rengaramanujam, Kanagaraj
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2021, 34 (02) : 289 - 299
  • [42] Inter-rater reliability of physiotherapists using the Pirani scoring system for clubfoot: comparison with a modified five-point scale
    Harvey, Nicole J.
    Mudge, Anita J.
    Daley, Deborah T.
    Sims, Susan K.
    Adams, Roger D.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2014, 23 (06): : 493 - 500
  • [43] Between-session and inter-rater reliability of the modified tuck jump assessment in healthy adult athletes
    Gokeler, Alli
    Dingenen, Bart
    PHYSICAL THERAPY IN SPORT, 2019, 37 : 10 - 14
  • [44] Inter-rater reliability of a modified version of Delitto et al.'s classification-based system for low back pain: a pilot study
    Apeldoorn, Adri T.
    van Helvoirt, Hans
    Ostelo, Raymond W.
    Meihuizen, Hanneke
    Kamper, Steven J.
    van Tulder, Maurits W.
    de Vet, Henrica C. W.
    JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2016, 24 (02) : 98 - 110
  • [45] Inter-rater reliability between experienced and inexperienced otolaryngologists using Koo's drug-induced sleep endoscopy classification system
    Koo, Soo Kweon
    Lee, Sang Hoon
    Koh, Tae Kyung
    Kim, Young Jun
    Moon, Ji Seung
    Lee, Ho Byung
    Park, Geun Hyung
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (05) : 1525 - 1531
  • [46] Inter-rater reliability between experienced and inexperienced otolaryngologists using Koo’s drug-induced sleep endoscopy classification system
    Soo Kweon Koo
    Sang Hoon Lee
    Tae Kyung Koh
    Young Jun Kim
    Ji Seung Moon
    Ho Byung Lee
    Geun Hyung Park
    European Archives of Oto-Rhino-Laryngology, 2019, 276 : 1525 - 1531
  • [47] Inter-rater reliability of Rolimeter measurements between anterior cruciate ligament injured and normal contra lateral knees
    Papandreou, MG
    Antonogiannakis, E
    Karabalis, C
    Karliaftis, K
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (07) : 592 - 597
  • [48] Inter-rater reliability of Rolimeter measurements between anterior cruciate ligament injured and normal contra lateral knees
    Maria G. Papandreou
    Emmanuel Antonogiannakis
    Christos Karabalis
    Konstantinos Karliaftis
    Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 592 - 597
  • [49] Three-dimensional intra-rater and inter-rater reliability during a posed smile using a video-based motion analyzing system
    Mishima, Katsuaki
    Umeda, Hirotsugu
    Nakano, Asuka
    Shiraishi, Ruriko
    Hori, Sayaka
    Ueyama, Yoshiya
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (05) : 428 - 431
  • [50] Intra- and inter-rater reliability of a three-dimensional classification system for intertrochanteric fracture using computed tomography
    Wada, Keizo
    Mikami, Hiroshi
    Toki, Shunichi
    Amari, Rui
    Takai, Michihiro
    Sairyo, Koichi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (11): : 2682 - 2685