Development of an electrochemical sulfite biosensor by immobilization of sulfite oxidase on conducting polyaniline film

被引:36
|
作者
Bahmani, Baharak [1 ]
Moztarzadeh, Fathollah [1 ]
Rabiee, Mohammad [1 ]
Tahriri, Mohammadreza [1 ]
机构
[1] Amirkabir Univ Technol, Fac Biomed Engn, Biomat Grp, Ctr Excellence, Tehran, Iran
关键词
Sulfite biosensor; Polyaniline; Sulfite oxidase; Enzyme; BIOELECTROCHEMICAL RESPONSE; ELECTRODE; ALUMINUM; HEXACYANOFERRATE; POLYPYRROLE; SUBSTRATE; DEHYDROGENASE; ENTRAPMENT; POLYMERS; SAMPLES;
D O I
10.1016/j.synthmet.2010.10.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, a biosensor was developed for the determination of sulfite. The bioelectrochemical response of the enzyme-modified electrode based on electrochemical incorporation of sulfite oxidase into polyaniline aluminum modified electrode was investigated. Electropolymerization of polyaniline and simultaneous immobilization of sulfite oxidase on the aluminum were performed in an aqueous solution containing sulfite oxidase. The sulfite biosensor constructed by cycling the potential scan between +1.2 and -0.5 V vs. saturated calomel electrode (SCE) that showed a sensitive response to sulfite with a linear calibration graph in the concentration ranges of 0.006-5 mM sulfite and detection limit 0.002 mM sulfite (S/N = 3). The obtained results from the stability tests of the biosensor show that the sulfite biosensor can be used for two different applications, for immediate usage and long term usage. Also, the bioelectrochemical response of the enzyme-modified electrode as a sulfite biosensor was evaluated at different experimental conditions. The optimum pH when using phosphate buffer and temperature were 8.5 and 35 degrees C, respectively. Finally, the apparent Michaelis-Menten constant was determined which has value of 0.365 mM which is really close to the magnitude of the Michaelis-Menten constant of free sulfite oxidase that shows the enzyme was not chemically modified and has its usual kinetic reaction. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2653 / 2657
页数:5
相关论文
共 50 条
  • [1] A Sulfite Biosensor Fabricated by Immobilization of Sulfite Oxidase on Aluminum Electrode Modified with Electropolymerized Conducting Film (Polyaniline)
    Bahmani, B.
    Moztarzadeh, F.
    Hossini, M.
    Rabiee, M.
    Tahriri, M.
    Rezvannia, M.
    Alizadeh, M.
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (02) : 923 - 930
  • [2] A Hybrid Enzyme Biosensor Based on Sulfite Oxidase and Glucose Oxidase for the Analyzing of Sulfite and Glucose
    Sezginturk, Mustafa Kemal
    Alacam, Sencer
    Altug, Cagri
    Akbayirli, Pinar
    Dinckaya, Erhan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (02): : 153 - 162
  • [3] A SULFITE BIOSENSOR - COUPLING OF SULFITE OXIDASE (EC 1.8.3.1) TO A TTFTCNQ ELECTRODE
    KORELL, U
    LENNOX, RB
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 351 (1-2): : 137 - 143
  • [4] Sulfite biosensor based on osmium redox polymer wired sulfite oxidase
    Spricigo, Roberto
    Richter, Claudia
    Leimkuehler, Silke
    Gorton, Lo
    Scheller, Frieder W.
    Wollenberger, Ulla
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2010, 354 (1-3) : 314 - 319
  • [5] Potentiometric sulfite biosensor based on entrapment of sulfite oxidase in a polypyrrole film on a platinum electrode modified with platinum nanoparticles
    Samuel B. Adeloju
    Shahid Hussain
    Microchimica Acta, 2016, 183 : 1341 - 1350
  • [6] Potentiometric sulfite biosensor based on entrapment of sulfite oxidase in a polypyrrole film on a platinum electrode modified with platinum nanoparticles
    Adeloju, Samuel B.
    Hussain, Shahid
    MICROCHIMICA ACTA, 2016, 183 (04) : 1341 - 1350
  • [7] Sulfite determination using sulfite oxidase biosensor based glassy carbon electrode coated with thin mercury film
    Dinckaya, Erhan
    Sezginturk, Mustafa Kemal
    Akyilmaz, Erol
    Ertas, F. Nil
    FOOD CHEMISTRY, 2007, 101 (04) : 1540 - 1544
  • [8] The Effect of Electrode's Material on Immobilization of Sulfite Oxidase Enzyme in Construction of Sulfite Biosensors
    Ghoseyri, Airin
    Farahbakhsh, Afshin
    Khakpur, Sajad
    Hosseinfakhrabadi, Nahid
    ADVANCED DESIGNS AND RESEARCHES FOR MANUFACTURING, PTS 1-3, 2013, 605-607 : 1387 - +
  • [9] Highly Sensitive and Stable Electrochemical Sulfite Biosensor Incorporating a Bacterial Sulfite Dehydrogenase
    Kalimuthu, Palraj
    Tkac, Jan
    Kappler, Ulrike
    Davis, Jason J.
    Bernhardt, Paul V.
    ANALYTICAL CHEMISTRY, 2010, 82 (17) : 7374 - 7379
  • [10] Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer
    Abass, AK
    Hart, JP
    Cowell, D
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) : 148 - 153