Reducing Distortions in Diffusion-Weighted Echo Planar Imaging With a Dual-Echo Blip-Reversed Sequence

被引:46
作者
Gallichan, Daniel [1 ]
Andersson, Jesper L. R. [1 ]
Jenkinson, Mark [1 ]
Robson, Matthew D. [1 ]
Miller, Karla L. [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Ctr Funct Magnet Resonance Imaging Brain, Oxford OX3 9DU, England
基金
英国生物技术与生命科学研究理事会;
关键词
DTI; distortion-correction; parallel imaging; MRI; EPI; GEOMETRIC DISTORTION; SPIN-ECHO; EPI; IMAGES; MRI; REDUCTION; ARTIFACTS;
D O I
10.1002/mrm.22318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The inherent distortions in echo-planar imaging that arise due to inhomogeneities in the static magnetic field can lead to difficulties when attempting to obtain structurally accurate diffusion-tensor imaging data. Parallel acceleration techniques can reduce the magnitude of these distortions but do not remove them entirely. Images can be corrected using a measured field map, but this is prone to error. One approach to correcting for these distortions, referred to here as "blip-reversed" echo-planar imaging, involves collecting a second set of images with the phase encoding reversed. Here, a novel approach to collecting blip-reversed echo-planar imaging data for diffusion-tensor imaging is presented: a dual-echo sequence is used in which the phase-encoding direction of the second echo is swapped compared to the first echo. This allows benefits of the blip-reversed approach to be exploited, with only a modest increase in scan time and, due to the extra data acquired, no significant loss of signal-to-noise efficiency. A novel approach to recombining blip-reversed data is also presented, which involves refining the measured field map, using an algorithm to minimize the difference between the corrected images. The field map refinement is also applicable to conventionally acquired blip-reversed sequences. Magn Reson Med 64:382-390, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:382 / 390
页数:9
相关论文
共 31 条
[1]  
Andersson JL, 2004, P INT SOC MAGN RES M, P87
[2]   A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI [J].
Andersson, JLR ;
Skare, S .
NEUROIMAGE, 2002, 16 (01) :177-199
[3]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[4]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[5]  
BOWTELL R, 1994, P ISMRM 2 SCI M EXH, P910
[6]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[7]  
Chronik B, 2000, MAGN RESON MATER PHY, V10, P131
[8]   Diffusion-based tractography in neurological disorders: concepts, applications, and future developments [J].
Ciccarelli, Olga ;
Catani, Marco ;
Johansen-Berg, Heidi ;
Clark, Chris ;
Thompson, Alan .
LANCET NEUROLOGY, 2008, 7 (08) :715-727
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]   A global optimisation method for robust affine registration of brain images [J].
Jenkinson, M ;
Smith, S .
MEDICAL IMAGE ANALYSIS, 2001, 5 (02) :143-156