Assessment of Material Identification Errors, Image Quality, and Radiation Doses Using Small Animal Spectral Photon-Counting CT

被引:12
作者
Marfo, Emmanuel [1 ]
Anderson, Nigel G. [1 ]
Butler, Anthony P. H. [1 ,2 ,3 ]
Schleich, Nanette [4 ]
Carbonez, Pierre [1 ,3 ]
Damet, Jerome [1 ,3 ,5 ]
Lowe, Chiara [1 ]
Healy, Joe [2 ]
Chernoglazov, Alexander I. [2 ]
Moghiseh, Mahdieh [1 ,2 ]
Raja, Aamir Y. [1 ,2 ]
机构
[1] Univ Otago, Dept Radiol, Christchurch 8011, New Zealand
[2] MARS Bioimaging Ltd, Christchurch 8041, New Zealand
[3] European Org Nucl Res CERN, CH-1211 Geneva, Switzerland
[4] Univ Otago, Dept Radiat Therapy, Wellington 6242, New Zealand
[5] Univ Lausanne Hosp, Inst Radiat Phys, CH-1011 Lausanne, Switzerland
关键词
Absorbed dose; image quality; material decomposition; Medipix; molecular imaging; photon-counting CT; spectral CT; MATERIAL DECOMPOSITION; COMPUTED-TOMOGRAPHY; GOLD NANOPARTICLES; CONTRAST AGENT; FEASIBILITY; SYSTEM; NOISE;
D O I
10.1109/TRPMS.2020.3003260
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photon-counting CT offers the potential to provide new diagnostic information. In this study, we sought to determine the interplay between material identification errors, image quality indicators, and radiation doses using photon-counting spectral CT, and to determine whether this relationship is replicated in spectral CT scans of mice. Custom-built Perspex phantoms were used to measure signal-to-noise ratio (SNR) and spatial resolution, and to measure radiation dose using thermoluminescent dosimeters. A multicontrast calibration phantom containing inserts with different concentrations of gadolinium (1, 2, 4, and 8 mg/mL), hydroxyapatite rods (0, 54.3, 104.3, 211.7, 402.3, and 808.5 mg/mL) along with water and lipid was used to assess material identification errors. Image acquisition was performed using the MARS photon-counting scanner with four energy channels (30-45, 45-60, 60-78, and 78-118 keV) at four different tube currents (24, 34, 44, and 55 mu A). As increased tube current showed no significant effect on material characterization, small animal dosimetry was performed with 24-mu A tube current using two noncontrast mice and one mouse injected with gadolinium. Results demonstrated that a tube current increase from 24 to 54 mu A improved the SNR and spatial resolution by <10%, gadolinium identification by <20% (for 1 mg/mL) but radiation dose increased by >160%. Imaging results of the mice showed no obvious artefacts, and the mean absorbed dose measured for the three mice was 27.3 +/- 2.4 mGy. The results suggest that the energy resolving capability of photon-counting CT maintains diagnostically relevant image quality with high levels of material discrimination at reduced radiation dose.
引用
收藏
页码:578 / 587
页数:10
相关论文
共 42 条
[1]   Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays [J].
Aamir, R. ;
Lansley, S. P. ;
Zainon, R. ;
Fiederle, M. ;
Fauler, A. ;
Greiffenberg, D. ;
Butler, P. H. ;
Butler, A. P. H. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[2]  
Aamir R, J INSTRUM, V9, P11
[3]   Clinical applications of spectral molecular imaging: potential and challenges [J].
Anderson, Nigel G. ;
Butler, Anthony P. .
CONTRAST MEDIA & MOLECULAR IMAGING, 2014, 9 (01) :3-12
[4]  
[Anonymous], 2013, E169595 ASTM, P1
[5]   To bin or not to bin? The effect of CT system limiting resolution on noise and detectability [J].
Baek, Jongduk ;
Pineda, Angel R. ;
Pelc, Norbert J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05) :1433-1446
[6]   Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging [J].
Ballabriga, R. ;
Alozy, J. ;
Campbell, M. ;
Frojdh, E. ;
Heijne, E. H. M. ;
Koenig, T. ;
Llopart, X. ;
Marchal, J. ;
Pennicard, D. ;
Poikela, T. ;
Tlustos, L. ;
Valerio, P. ;
Wong, W. ;
Zuber, M. .
JOURNAL OF INSTRUMENTATION, 2016, 11
[7]   The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging [J].
Ballabriga, R. ;
Alozy, J. ;
Blaj, G. ;
Campbell, M. ;
Fiederle, M. ;
Frojdh, E. ;
Heijne, E. H. M. ;
Llopart, X. ;
Pichotka, M. ;
Procz, S. ;
Tlustos, L. ;
Wong, W. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[8]   MARS-MD: rejection based image domain material decomposition [J].
Bateman, C. J. ;
Knight, D. ;
Brandwacht, B. ;
Mc Mahon, J. ;
Healy, J. ;
Panta, R. ;
Aamir, R. ;
Rajendran, K. ;
Moghiseh, M. ;
Ramyar, M. ;
Rundle, D. ;
Bennett, J. ;
de Ruiter, N. ;
Smithies, D. ;
Bell, S. T. ;
Doesburg, R. ;
Chernoglazov, A. ;
Mandalika, V. B. H. ;
Walsh, M. ;
Shamshad, M. ;
Anjomrouz, M. ;
Atharifard, A. ;
Broeke, L. Vanden ;
Bheesette, S. ;
Kirkbride, T. ;
Anderson, N. G. ;
Gieseg, S. P. ;
Woodfield, T. ;
Renaud, P. F. ;
Butler, A. P. H. ;
Butler, P. H. .
JOURNAL OF INSTRUMENTATION, 2018, 13
[9]   Winds of change in imaging of calcium crystal deposition diseases [J].
Becce, Fabio ;
Viry, Anais ;
Stamp, Lisa K. ;
Pascart, Tristan ;
Budzik, Jean-Francois ;
Raja, Aamir ;
Adebileje, Sikiru A. ;
Alexander, Steven D. ;
Amma, Maya R. ;
Anjomrouz, Marzieh ;
Asghariomabad, Fatemeh ;
Atharifard, Ali ;
Atlas, James ;
Bamford, Benjamin ;
Bell, Stephen T. ;
Bheesette, Srinidhi ;
Butler, Anthony P. H. ;
Butler, Philip H. ;
Carbonez, Pierre ;
Chambers, Claire ;
Chernoglazov, Alexander I. ;
Dahal, Shishir ;
Damet, Jerome ;
de Ruiter, Niels J. A. ;
Doesburg, Robert M. N. ;
Duncan, Neryda ;
Gieseg, Steven P. ;
Goulter, Brian P. ;
Gurney, Sam ;
Healy, Joseph L. ;
Kanithi, Praveenkumar ;
Kirkbride, Tracy ;
Lansley, Stuart P. ;
Lowe, Chiara ;
Mandalika, V. B. H. ;
Marfo, Emmanuel ;
Matanaghi, Aysouda ;
Moghiseh, Mandieh ;
Palmer, David ;
Panta, Raj K. ;
Prebble, Hannah M. ;
Raja, Aamir Y. ;
Renaud, Peter ;
Schleich, Nanette ;
Searle, Emily ;
Sheeja, Jereena S. ;
Uddin, Rayhan ;
Broeke, Lieza Vanden ;
Vivek, V. S. ;
Walker, E. Peter .
JOINT BONE SPINE, 2019, 86 (06) :665-668
[10]  
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326