THE INFLUENCE OF BONE-DENSITY ON IN VIVO K X-RAY FLUORESCENCE BONE-LEAD MEASUREMENTS

被引:2
作者
Lodwick, Camille J. [1 ]
Lodwick, Jeffrey C. [2 ]
Spitz, Henry B. [3 ]
机构
[1] Oregon State Univ, Dept Nucl Engn & Radiat Hlth Phys, Corvallis, OR 97331 USA
[2] Occupat Safety & Hlth Adm, US Dept Labor, Salt Lake City, UT 84070 USA
[3] Univ Cincinnati, Dept Mech Ind & Nucl Engn, Cincinnati, OH 45221 USA
来源
HEALTH PHYSICS | 2011年 / 100卷 / 05期
关键词
bones; human; Monte Carlo; Pb-210; x rays; CALIBRATION;
D O I
10.1097/HP.0b013e3181f725af
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Mathematical simulations and benchmark measurements were performed to assess the impact that normal variations in human calcium content have on in vivo K x-ray fluorescence measurements of lead in bone. Four sets of cortical bone tissue simulants were fabricated containing from 20.8% to 23.8% calcium ( by weight) for measurement in a surrogate ( phantom) of the human leg. The net counts detected in the coherent backscatter peak at 88.034 keV using a Cd-109 source indicate a positive trend, with a variability of up to 17% over the range of assessed calcium content. Mathematical simulations confirm this trend and also demonstrate that the contribution of 87.3 keV Pb K-beta 2 counts, which are unresolved in measurements, do not contribute significantly to the coherent peak at low levels of bone-lead content. Both measurements and simulations confirm that calcium is a statistically significant parameter in predicting the K-XRF response and suggest that lead levels may be over-predicted for individuals having low bone density compared to the calibration matrix. Simulations identify a 4.5% negative bias in measured lead values for each 1% increase in calcium weight percent in the bone matrix as compared to the calibration matrix. It is therefore important to accommodate this uncertainty when performing epidemiological studies of populations having a wide range of bone densities. Health Phys. 100(5):502-507; 2011
引用
收藏
页码:502 / 507
页数:6
相关论文
共 50 条
  • [41] Effect of bone age and anatomy on the variability of the bovine bone by-product by Terahertz time-domain spectroscopy and energy-dispersive X-ray microanalysis
    Wahaia, Faustino
    Kasalynas, Irmantas
    Karaliunas, Mindaugas
    Urbanowicz, Andrzej
    Seifert, Birger
    Valusis, Gintaras
    Ferraro, Vincenza
    [J]. FOOD BIOSCIENCE, 2024, 59
  • [42] Monte Carlo estimation of radiation doses in red bone marrow and breast in common pediatric X-ray examinations
    Gialousis, George I.
    Yakoumakis, Emmanuel N.
    Dimitriadis, Anastasios I.
    Papouli, Zografia K.
    Yakoumakis, Nikolaos E.
    Tsalafoutas, Ioannis A.
    Papadopoulou, Despoina I.
    Georgiou, Evangelos K.
    [J]. HEALTH PHYSICS, 2008, 95 (03): : 331 - 336
  • [43] X-ray absorptiometry for non-destructive monitoring of the salt uptake in bone-in raw hams during salting
    Fulladosa, E.
    Munoz, I.
    Serra, X.
    Arnau, J.
    Gou, P.
    [J]. FOOD CONTROL, 2015, 47 : 37 - 42
  • [44] Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy
    Nobah, Ahmad
    Moftah, Belal
    Tomic, Nada
    Devic, Slobodan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (03): : 80 - 89
  • [45] A quantitative Monte Carlo modelling of the uranium and plutonium X-ray fluorescence (XRF) response from a hybrid K-edge/K-XRF densitometer
    Berlizoy, A. N.
    Sharikov, D. A.
    Ottmar, H.
    Eberle, H.
    Galy, J.
    Luetzenkirchen, K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (01) : 127 - 135
  • [46] The Influence of B4C Film Density on Damage Threshold Based on Monte Carlo Method for X-ray Mirror
    Sui, Tingting
    Zhuo, Haohui
    Tang, Anchun
    Ju, Xin
    [J]. MATERIALS, 2024, 17 (05)
  • [47] Absolute measurements of anomalous small-angle X-ray scattering intensity using glassy carbon at the Mg K absorption edge
    Aoyama, Keita
    Okuda, Hiroshi
    Lin, Shan
    Mase, Kazuhiko
    Kitajima, Yoshinori
    Tamenori, Yusuke
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (07)
  • [48] Reconstruction of patient-specific 3D bone model from biplanar X-ray images and point distribution models
    Zheng, Guoyan
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 1197 - 1200
  • [49] DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR TOTAL-BODY AND REGIONAL BONE-MINERAL AND SOFT-TISSUE COMPOSITION
    MAZESS, RB
    BARDEN, HS
    BISEK, JP
    HANSON, J
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (06) : 1106 - 1112
  • [50] Block-Deep: A Hybrid Secure Data Storage and Diagnosis Model for Bone Fracture Identification of Athlete From X-Ray and MRI Images
    Mohammad, Farah
    Al-Ahmadi, Saad
    Al-Muhtadi, Jalal
    [J]. IEEE ACCESS, 2023, 11 : 142360 - 142370