THE INFLUENCE OF BONE-DENSITY ON IN VIVO K X-RAY FLUORESCENCE BONE-LEAD MEASUREMENTS

被引:2
作者
Lodwick, Camille J. [1 ]
Lodwick, Jeffrey C. [2 ]
Spitz, Henry B. [3 ]
机构
[1] Oregon State Univ, Dept Nucl Engn & Radiat Hlth Phys, Corvallis, OR 97331 USA
[2] Occupat Safety & Hlth Adm, US Dept Labor, Salt Lake City, UT 84070 USA
[3] Univ Cincinnati, Dept Mech Ind & Nucl Engn, Cincinnati, OH 45221 USA
来源
HEALTH PHYSICS | 2011年 / 100卷 / 05期
关键词
bones; human; Monte Carlo; Pb-210; x rays; CALIBRATION;
D O I
10.1097/HP.0b013e3181f725af
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Mathematical simulations and benchmark measurements were performed to assess the impact that normal variations in human calcium content have on in vivo K x-ray fluorescence measurements of lead in bone. Four sets of cortical bone tissue simulants were fabricated containing from 20.8% to 23.8% calcium ( by weight) for measurement in a surrogate ( phantom) of the human leg. The net counts detected in the coherent backscatter peak at 88.034 keV using a Cd-109 source indicate a positive trend, with a variability of up to 17% over the range of assessed calcium content. Mathematical simulations confirm this trend and also demonstrate that the contribution of 87.3 keV Pb K-beta 2 counts, which are unresolved in measurements, do not contribute significantly to the coherent peak at low levels of bone-lead content. Both measurements and simulations confirm that calcium is a statistically significant parameter in predicting the K-XRF response and suggest that lead levels may be over-predicted for individuals having low bone density compared to the calibration matrix. Simulations identify a 4.5% negative bias in measured lead values for each 1% increase in calcium weight percent in the bone matrix as compared to the calibration matrix. It is therefore important to accommodate this uncertainty when performing epidemiological studies of populations having a wide range of bone densities. Health Phys. 100(5):502-507; 2011
引用
收藏
页码:502 / 507
页数:6
相关论文
共 50 条
  • [31] REGIONAL VARIATIONS IN BONE-MINERAL DENSITY AS ASSESSED WITH DUAL-ENERGY PHOTON-ABSORPTIOMETRY AND DUAL X-RAY ABSORPTIOMETRY
    FEYERABEND, AJ
    LEAR, JL
    RADIOLOGY, 1993, 186 (02) : 467 - 469
  • [32] X-ray phase-contrast imaging study of soft-tissue and bone samples
    Gao, DC
    Pogany, A
    Stevenson, AW
    Gureyev, T
    Wilkins, SW
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 346 - 355
  • [33] Bone mineral measurement of phalanges: Comparison of radiographic absorptiometry and area dual X-ray absorptiometry
    Gulam, M
    Thornton, MM
    Hodsman, AB
    Holdsworth, DW
    RADIOLOGY, 2000, 216 (02) : 586 - 591
  • [34] Classification of Canine Maturity and Bone Fracture Time Based on X-Ray Images of Long Bones
    Ergun, Gulnur Begum
    Guney, Selda
    IEEE ACCESS, 2021, 9 : 109004 - 109011
  • [35] Methods and technologies for exploring alterations on bone surface electron properties' after x-ray irradiation
    Zakaria, Mohamad
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 9 (03) : 230 - 248
  • [36] Effect of high-energy X-ray doses on bone elastic properties and residual strains
    Singhal, A.
    Deymier-Black, Alix C.
    Almer, J. D.
    Dunand, D. C.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (08) : 1774 - 1786
  • [37] High-Resolution Chest X-Ray Bone Suppression Using Unpaired CT Structural Priors
    Li, Han
    Han, Hu
    Li, Zeju
    Wang, Lei
    Wu, Zhe
    Lu, Jingjing
    Zhou, S. Kevin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3053 - 3063
  • [38] Bone Cancer Detection and Classification Using Owl Search Algorithm With Deep Learning on X-Ray Images
    Alabdulkreem, Eatedal
    Saeed, Muhammad Kashif
    Alotaibi, Saud S.
    Allafi, Randa
    Mohamed, Abdullah
    Hamza, Manar Ahmed
    IEEE ACCESS, 2023, 11 : 109095 - 109103
  • [39] RAGCN: Region Aggregation Graph Convolutional Network for Bone Age Assessment From X-Ray Images
    Li, Xiang
    Jiang, Yuchen
    Liu, Yiliu
    Zhang, Jiusi
    Yin, Shen
    Luo, Hao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [40] USE OF PORTABLE X-RAY FLUORESCENCE (PXRF) IN VIVO AS AN ALTERNATIVE TECHNIQUE FOR THE ASSESSMENT OF IRON LEVELS IN PATIENTS WITH THALASSEMIA AND HEMOCHROMATOSIS
    Estevam, Marcelo
    Appoloni, Carlos Roberto
    HEALTH PHYSICS, 2013, 104 (02): : 132 - 138