A Normal Sensor Calibration Method Based on an Extended Kalman Filter for Robotic Drilling

被引:15
作者
Chen, Dongdong [1 ]
Yuan, Peijiang [1 ]
Wang, Tianmiao [1 ]
Cai, Ying [1 ]
Tang, Haiyang [2 ]
机构
[1] Beihang Univ, Sch Mech Engn & Automat, Beijing 100191, Peoples R China
[2] Shanghai Aircraft Mfg Co Ltd, Shanghai 200436, Peoples R China
基金
中国国家自然科学基金;
关键词
parameter identification; normal adjustment; extended Kalman filter; laser displacement sensor; robotic drilling system; NORMAL DIRECTION; QUALITY;
D O I
10.3390/s18103485
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To enhance the perpendicularity accuracy in the robotic drilling system, a normal sensor calibration method is proposed to identify the errors of the zero point and laser beam direction of laser displacement sensors simultaneously. The procedure of normal adjustment of the robotic drilling system is introduced firstly. Next the measurement model of the zero point and laser beam direction on a datum plane is constructed based on the principle of the distance measurement for laser displacement sensors. An extended Kalman filter algorithm is used to identify the sensor errors. Then the surface normal measurement and attitude adjustments are presented to ensure that the axis of the drill bit coincides with the normal at drilling point. Finally, simulations are conducted to study the performance of the proposed calibration method and experiments are carried out on a robotic drilling system. The simulation and experimental results show that the perpendicularity of the hole is within 0.2 degrees. They also demonstrate that the proposed calibration method has high accuracy of parameter identification and lays a basis for high-precision perpendicularity accuracy of drilling in the robotic drilling system.
引用
收藏
页数:16
相关论文
共 29 条
[21]   Fatigue performance of production-quality aircraft fastener holes [J].
Ralph, W. Carter ;
Johnson, W. Steven ;
Makeev, Andrew ;
Newman, James C., Jr. .
INTERNATIONAL JOURNAL OF FATIGUE, 2007, 29 (07) :1319-1327
[22]   Calibration technology in application of robot-laser scanning system [J].
Ren, YongJie ;
Yin, ShiBin ;
Zhu, JiGui .
OPTICAL ENGINEERING, 2012, 51 (11)
[23]   New design of a compact aero-robotic drilling end effector: An experimental analysis [J].
Shi Zhenyun ;
Yuan Peijiang ;
Wang Qishen ;
Chen Dongdong ;
Wang Tianmiao .
CHINESE JOURNAL OF AERONAUTICS, 2016, 29 (04) :1132-1141
[24]   Effect of production variables on the fatigue behaviour of riveted lap joints [J].
Skorupa, M. ;
Skorupa, A. ;
Machniewicz, T. ;
Korbel, A. .
INTERNATIONAL JOURNAL OF FATIGUE, 2010, 32 (07) :996-1003
[25]   A comparison study of algorithms for surface normal determination based on point cloud data [J].
Song, Tao ;
Xi, Fengfeng ;
Guo, Shuai ;
Ming, Zhifa ;
Lin, Yu .
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2015, 39 :47-55
[26]   Systematic estimation of state noise statistics for extended Kalman filters [J].
Valappil, J ;
Georgakis, C .
AICHE JOURNAL, 2000, 46 (02) :292-308
[27]  
Wang Z., 2017, P 2017 IOP C SER MAT
[28]   Approach for calibrating position of displacement sensor mounted on robot end-effector [J].
Yuan, Kang-Zheng ;
Zhu, Wei-Dong ;
Chen, Lei ;
Xue, Lei ;
Qi, Wen-Gang .
Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2015, 49 (05) :829-834
[29]   A micro-adjusting attitude mechanism for autonomous drilling robot end-effector [J].
Yuan PeiJiang ;
Wang QiShen ;
Shi ZhenYun ;
Wang TianMiao ;
Wang ChengKun ;
Chen DongDong ;
Shen LiHeng .