A data acquisition system for two-dimensional position sensitive micropattern gas detectors with delay-line readout

被引:8
作者
Hanu, A. R. [1 ,2 ]
Prestwich, W. V. [1 ]
Byun, S. H. [1 ]
机构
[1] McMaster Univ, Dept Med Phys & Appl Radiat Sci, Hamilton, ON L8S 4K1, Canada
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
关键词
Delay-line readout; Image acquisition system; Time-to-digital converter; FPGA; Micropattern gas detectors; GEM DETECTORS;
D O I
10.1016/j.nima.2015.01.053
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a data acquisition (DAQ) system for two-dimensional position sensitive micropattern gas detectors using the delay-line method for readout. The DAQ system consists of a field programmable gate array (FPGA) as the main data processor and our time-to-digital (TDC) mezzanine card for making time measurements. We developed the TDC mezzanine card around the Acam TDC-GPX ASIC and it features four independent stop channels referenced to a common start, a typical timing resolution of similar to 81ps, and a 17-bit measurement range, and is compliant with the VITA 57.1 standard. For our DAQ system, we have chosen the Xilinx SP601 development kit which features a single Spartan 6 FPGA, 128 MB of DDR2 memory, and a serial USB interface for communication. Output images consist of 1024 x 1024 square pixels, where each pixel has a 32-bit depth and corresponds to a time difference of 162 ps relative to its neighbours. When configured for a 250 ns acquisition window, the DAQ can resolve periodic event rates up to 1.8 x 10(6) Hz without any loses and will report a maximum event rate of 6.11 x 10(5) Hz for events whose arrival Limes follow Poisson statistics. The integral and differential non-linearities have also been measured and are better than 0.1% and 1.5%, respectively. Unlike commercial units, our DAQ system implements the delay-line image reconstruction algorithm entirely in hardware and is particularly attractive for its modularity, low cost, ease of integration, excellent linearity, and high throughput rate. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 12 条
[1]  
Acam Messelectronic gmbh, 2007, TDC GPX DAT
[2]   High rate X-ray imaging using multi-GEM detectors with a novel readout design [J].
Bachmann, S ;
Kappler, S ;
Ketzer, B ;
Müller, T ;
Ropelewski, L ;
Sauli, F ;
Schulte, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2) :104-108
[3]   Readout of GEM detectors using the Medipix2 CMOS pixel chip [J].
Bamberger, A. ;
Desch, K. ;
Renz, U. ;
Titov, M. ;
Vlasov, N. ;
Wienemann, P. ;
Zwerger, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (03) :361-370
[4]   A high-resolution CMOS time-to-digital converter utilizing a Vernier delay line [J].
Dudek, P ;
Szczepanski, S ;
Hatfield, JV .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2000, 35 (02) :240-247
[5]   Two-dimensional GEM imaging detector with delay-line readout [J].
Guedes, GP ;
Breskin, A ;
Chechik, R ;
Vartsky, D ;
Bar, D ;
Barbosa, AF ;
Marinho, PRB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03) :473-483
[6]  
Hanu A., 2014, THESIS MCMASTER U LI
[7]   Using a multilayer printed circuit board as position sensing electrode in a triple-GEM detector [J].
Marinho, PRB ;
Barbosa, AF ;
Guedes, GP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) :2917-2922
[8]   DELAY-LINE READOUT OF MICROCHANNEL PLATES [J].
SOBOTTKA, SE ;
WILLIAMS, MB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :348-351
[9]   Hardware-based TCP processor for Gigabit Ethernet [J].
Uchida, Tomohisa .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1631-1637
[10]   Optimization of the readout electronics for microchannel plate delay line anodes [J].
Vallerga, J ;
McPhate, J .
INSTRUMENTATION FOR UV/EUV ASTRONOMY AND SOLAR MISSIONS, 2000, 4139 :34-42