Factors related to the skin thickness of cardiovascular implantable electronic device pockets

被引:6
作者
Yatomi, Atsusuke [1 ]
Takami, Mitsuru [2 ]
Fukuzawa, Koji [2 ]
Kiuchi, Kunihiko [1 ]
Sakai, Jun [1 ]
Nakamura, Toshihiro [1 ]
Sonoda, Yusuke [1 ]
Takahara, Hiroyuki [1 ]
Nakasone, Kazutaka [1 ]
Yamamoto, Kyoko [1 ]
Suzuki, Yuya [1 ]
Tani, Kenichi [1 ]
Iwai, Hidehiro [1 ]
Nakanishi, Yusuke [1 ]
Hirata, Ken-ichi [2 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Internal Med, Div Cardiovasc Med, Kobe, Hyogo, Japan
[2] Kobe Univ, Grad Sch Med, Dept Internal Med, Sect Arrhythmia,Div Cardiovasc Med, Kobe, Hyogo, Japan
关键词
cardiovascular implantable electronic devices; device erosion; device infection; device pocket; skin thickness; HIGH-FREQUENCY ULTRASOUND; EUROPEAN-SOCIETY;
D O I
10.1111/jce.15613
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The skin overlying cardiovascular implantable electronic devices (CIEDs) sometimes becomes very thin after implantations, which could cause a device erosion. The factors related to the skin thickness of device pockets have not been elucidated. This study aimed to evaluate the skin thickness of CIED pockets and search for the factors associated with the thickness. Methods Seventeen skin thickness points around the CIED pocket were measured through ultrasonography in each patient. Results A total of 101 patients (76 +/- 11 years, 26 female) were enrolled. The median duration from the implantation to the examination was 95 months (quartile: 52.5-147.5). The median skin thickness overlying the device was 4.1 mm (3.3-5.9). Patients with heart failure and malignancy had thinner skin overlying the CIED than those without. A significant correlation existed between skin thickness and body mass index (BMI), hemoglobin, serum creatinine, estimated glomerular filtration rate (eGFR), and left ventricular ejection fraction. In contrast, age, gender, and device size did not exhibit a significant correlation with skin thickness. A multivariate logistic regression analysis revealed that chronic heart failure and a decrease in the eGFR and BMI were independent predictive factors of "very thin (<= 3.3 mm)" skin of the CIED pocket late after an implantation. Conclusion Aside from a low BMI, the comorbidities (low hemoglobin, heart failure, and renal dysfunction) had a stronger impact on the skin thickness overlying the device than the device size. A careful observation of the device pocket should be performed in patients with those risk factors.
引用
收藏
页码:1847 / 1856
页数:10
相关论文
共 16 条
[1]   European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS) [J].
Blomstrom-Lundqvist, Carina ;
Traykov, Vassil ;
Erba, Paola Anna ;
Burri, Haran ;
Nielsen, Jens Cosedis ;
Bongiorni, Maria Grazia ;
Poole, Jeanne ;
Boriani, Giuseppe ;
Costa, Roberto ;
Deharo, Jean-Claude ;
Epstein, Laurence M. ;
Saghy, Laszlo ;
Snygg-Martin, Ulrika ;
Starck, Christoph ;
Tascini, Carlo ;
Strathmore, Neil .
EUROPACE, 2020, 22 (04) :515-516
[2]   Skin barrier immunity and ageing [J].
Chambers, Emma S. ;
Vukmanovic-Stejic, Milica .
IMMUNOLOGY, 2020, 160 (02) :116-125
[3]   Diagnosis and management of infections involving implantable electrophysiologic cardiac devices [J].
Chua, JD ;
Wilkoff, BL ;
Lee, I ;
Juratli, N ;
Longworth, DL ;
Gordon, SM .
ANNALS OF INTERNAL MEDICINE, 2000, 133 (08) :604-608
[4]  
Deegan, 2021, PREPRINT, DOI 10.22541/au.162740708.87184630/v1
[5]   Frailty and body mass index are associated with biophysical properties of the skin in community-dwelling older adults [J].
Iizaka, Shinji .
JOURNAL OF TISSUE VIABILITY, 2018, 27 (03) :141-145
[6]   Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines [J].
Laurent, Aurelie ;
Mistretta, Frederic ;
Bottigioli, David ;
Dahel, Karima ;
Goujon, Catherine ;
Nicolas, Jean Francois ;
Hennino, Anca ;
Laurent, Philippe E. .
VACCINE, 2007, 25 (34) :6423-6430
[7]   Iron deficiency anaemia [J].
Lopez, Anthony ;
Cacoub, Patrice ;
Macdougall, Iain C. ;
Peyrin-Biroulet, Laurent .
LANCET, 2016, 387 (10021) :907-916
[8]   Subcutaneous adipose tissue thickness in adults - correlation with BMI and recommendations for pen needle lengths for subcutaneous self-injection [J].
Ludescher, Burkhard ;
Rommel, Marc ;
Willmer, Tobias ;
Fritsche, Andreas ;
Schick, Fritz ;
Machann, Juergen .
CLINICAL ENDOCRINOLOGY, 2011, 75 (06) :786-790
[9]   The 11th World Survey of Cardiac Pacing and Implantable Cardioverter-Defibrillators: Calendar Year 2009-A World Society of Arrhythmia's Project [J].
Mond, Harry G. ;
Proclemer, Alessandro .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (08) :1013-1027
[10]   Clinical relevance of sarcopenia in chronic kidney disease [J].
Moorthi, Ranjani N. ;
Avin, Keith G. .
CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2017, 26 (03) :219-228