Diagnosis of Patent Foramen Ovale: The Combination of Contrast Transcranial Doppler, Contrast Transthoracic Echocardiography, and Contrast Transesophageal Echocardiography

被引:30
作者
Yang, Xiaoxue [1 ,2 ]
Wang, Hua [1 ]
Wei, Yajuan [1 ]
Zhai, Nina [3 ]
Liu, Baomin [1 ]
Li, Xiaopeng [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Ultrasound, Xian 710004, Peoples R China
[2] Northwest Women & Children Hosp, Dept Ultrasound, Xian 710061, Peoples R China
[3] Xi An Jiao Tong Univ, Affiliated Hosp 2, Transcranial Doppler Sonog Lab, Xian 710004, Peoples R China
关键词
TO-LEFT SHUNT; VALSALVA MANEUVER; METAANALYSIS; SENSITIVITY; INJECTIONS; ACCURACY;
D O I
10.1155/2020/8701759
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives. To access the distinct values of contrast transcranial Doppler (cTCD), contrast transthoracic echocardiography (cTTE), and contrast transesophageal echocardiography (cTEE) in the diagnosis of right-to-left shunt (RLS) due to patent foramen ovale (PFO) and to define the most practical strategy for the diagnosis of PFO. Methods. 102 patients with a high clinical suspicion for PFO had simultaneous cTCD, cTTE, and cTEE performed. The agitated saline mixed with blood was used to detect right-to-left shunt (RLS). Results. In all 102 patients, the shunt was detected at rest by cTCD in 60.78% of cases, by cTTE in 42.16%, and by cTEE in 47.06%. The positive results of all 3 techniques with Valsalva maneuver (VM) were significantly improved. cTCD showed higher pick-up rate than cTTE (98.04% vs. 89.22%; chi 2=12.452, p<0.05) and the cTEE (98.04% vs. 96.08%; nonsignificant difference) in the diagnosis of PFO. Nevertheless, cTEE, compared with cTTE, underestimated shunting in 44% of patients. The diameter of both PFO entrance and exit was significantly greater in patients with a severe shunt compared with a mild shunt (2.8 +/- 1.0 mm vs. 2.0 +/- 0.7 mm, t=3.135, p<0.05; 2.2 +/- 0.7 mm vs. 1.6 +/- 0.4 mm, t=-2.582, p<0.05). There was a nonsignificant difference in tunnel length between patients with mild shunting and severe shunting(9.3 +/- 2.7 mm vs. 9.4 +/- 2.9 mm; t=1.358, p>0.05). Conclusions. The best method to diagnose PFO should be the combination of cTCD, cTTE, and cTEE. And cTCD should be applied as the first choice for screening RLS. Then, cTTE should be performed to quantify the severity of the shunt. Last but not least, cTEE should be performed to assess the morphologies of PFO when the closure is planned. The study provides for clinicians the most practical strategy for diagnosing PFO in the future. However, further trials with a large sample size are required to confirm this finding.
引用
收藏
页数:7
相关论文
共 26 条
[1]   Transcranial Doppler and Transesophageal Echocardiography: Comparison of Both Techniques and Prospective Clinical Relevance of Transcranial Doppler in Patent Foramen Ovale Detection [J].
Caputi, Luigi ;
Carriero, Maria Rita ;
Falcone, Chiara ;
Parati, Eugenio ;
Piotti, Patrizia ;
Materazzo, Carlo ;
Anzola, Gian Paolo .
JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2009, 18 (05) :343-348
[2]   A comparison of contrast transthoracic echocardiography and contrast transcranial Doppler in cryptogenic stroke patients with patent foramen ovale [J].
Chen, Jie ;
Chen, Luyun ;
Hu, Wangwang ;
Ni, Xianda ;
Zhang, Zengrui ;
Feng, Xiaowen ;
Fan, Zijian ;
Chen, Cuiping ;
Qiu, Fengzhen ;
Shao, Bei .
BRAIN AND BEHAVIOR, 2019, 9 (05)
[3]  
Clarke N R A, 2004, Eur J Echocardiogr, V5, P176, DOI 10.1016/S1525-2167(03)00076-3
[4]   Closing the gap on patent foramen ovale and cryptogenic stroke [J].
Darmoch, Fahed ;
Al-Khadra, Yasser ;
Bacha, Homam Mousa ;
Soud, Mohammad ;
Alraies, M. Chadi .
EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2019, 17 (06) :389-394
[5]   Right-to-left-shunts detected by transesophageal echocardiography and transcranial Doppler sonography [J].
Droste, DW ;
Schmidt-Rimpler, CS ;
Wichter, T ;
Dittrich, R ;
Ritter, M ;
Stypmann, J ;
Ringelstein, EB .
CEREBROVASCULAR DISEASES, 2004, 17 (2-3) :191-196
[6]   COMPARISON OF DIFFERENT METHODS OF VALSALVA MANEUVER FOR RIGHT-TO-LEFT SHUNT DETECTION BY CONTRAST-ENHANCED TRANSCRANIAL DOPPLER [J].
Guo, Yu-Zhu ;
Gao, Yong-Sheng ;
Guo, Zhen-Ni ;
Niu, Peng-Peng ;
Yang, Yi ;
Xing, Ying-Qi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (05) :1124-1129
[7]   Diagnosis of Secondary Source of Right-to-Left Shunt With Balloon Occlusion of Patent Foramen Ova le and Power M-Mode Transcranial Doppler [J].
Jesurum, Jill T. ;
Fuller, Cindy J. ;
Renz, Joshua ;
Krabill, Kimberly A. ;
Spencer, Merrill P. ;
Reisman, Mark .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (06) :561-567
[8]   Sensitivity for detection of patent foramen ovale increased with increasing number of contrast injections: A descriptive study with contrast transesophageal echocardiography [J].
Johansson, Magnus C. ;
Helgason, Hrodmar ;
Dellborg, Mikael ;
Eriksson, Peter .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (05) :419-424
[9]   Pitfalls in Diagnosing PFO: Characteristics of False-Negative Contrast Injections during Transesophageal Echocardiography in Patients with Patent Foramen Ovales [J].
Johansson, Magnus C. ;
Eriksson, Peter ;
Guron, Cecilia Wallentin ;
Dellborg, Mikael .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (11) :1136-1142
[10]   TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND CONTRAST-TCD IN THE DETECTION OF A PATENT FORAMEN OVALE - EXPERIENCES WITH 111 PATIENTS [J].
KLOTZSCH, C ;
JANSSEN, G ;
BERLIT, P .
NEUROLOGY, 1994, 44 (09) :1603-1606