Thermodynamic analysis of vapor compression heat pump cycle for tap water heating and development of CO2 heat pump water heater for residential use

被引:62
作者
Saikawa, Michiyuki [1 ]
Koyama, Shigeru [2 ]
机构
[1] Cent Res Inst Elect Power Ind, 2-6-1 Nagasaka, Yokosuka, Kanagawa 2400196, Japan
[2] Kyushu Univ, 6-1 Kasuga Koen, Kasuga, Fukuoka 8168580, Japan
关键词
COP; CO2; refrigerant; Heat pump; Tap water heating;
D O I
10.1016/j.applthermaleng.2016.06.105
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ideal vapor compression cycle for tap water heating and its coefficient of performance (COP) have been studied theoretically at first. The ideal cycle is defined as the cycle whose high temperature heat source varies temperature with constant specific heat and other processes are same as the reverse Carnot cycle. The COP upper limit of single stage compression heat pump cycle for tap water heating with various refrigerants such as fluorocarbons and natural refrigerants was calculated. The refrigerant which achieves the highest COP for supplying hot water is CO2. Next, the prototype of CO2 heat pump water heater for residential use has been developed. Its outline and experimental results are described. Finally its further possibility of COP improvement has been studied. The COP considered a limit from a technical point of view was estimated about 6.0 at the Japanese shoulder season (spring and autumn) test condition of heating water from 17 degrees C to 65 degrees C at 16 degrees C heat source air temperature (dry bulb)/12 degrees C (wet bulb). (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1236 / 1243
页数:8
相关论文
共 17 条
[1]   Review of recent developments in advanced ejector technology [J].
Elbel, Stefan ;
Lawrence, Neal .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 62 :1-18
[2]   Historical and present developments of ejector refrigeration systems with emphasis on transcritical carbon dioxide air-conditioning applications [J].
Elbel, Stefan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07) :1545-1561
[3]  
Hashimoto K., 2006, IEA HEAT PUMP CTR NE, V24, P12
[4]  
Hirata M., 1998, P NAT WORK FLUID 98, P314
[5]   Theoretical evaluation of carbon dioxide refrigeration cycle [J].
Hwang, YH ;
Radermacher, R .
HVAC&R RESEARCH, 1998, 4 (03) :245-263
[6]  
Kohsokabe H., 2008, P 8 IIR GUST LOR C N, P1090
[7]  
Kusakari K., 2002, P 7 INT EN AG HEAT P, P101
[8]  
Lorentzen G., 1990, Patent No. [WO 90/07683, 9007683]
[9]  
Lorentzen G., 1994, P 1 INT C US NON SUB, P23
[10]   CO2-heat pump water heater:: characteristics, system design and experimental results [J].
Neksa, P ;
Rekstad, H ;
Zakeri, GR ;
Schiefloe, PA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (03) :172-179