A novel modality for the estimation of the enteroscope insertion depth during double-balloon enteroscopy

被引:18
作者
Li, Xiao-Bo [1 ]
Dai, Jun [1 ]
Chen, Hui-Min [1 ]
Zhuang, Jie [2 ]
Song, Yan [1 ]
Gao, Yun-Jie [1 ]
Ge, Zhi-Zheng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Gastroenterol, Shanghai Renji Hosp, Sch Med,Shanghai Inst Digest Dis, Shanghai 200001, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Surg, Shanghai Renji Hosp, Sch Med, Shanghai 200001, Peoples R China
关键词
WIRELESS CAPSULE ENDOSCOPY; SMALL-BOWEL; PULL ENTEROSCOPY; DIAGNOSTIC YIELD; PUSH ENTEROSCOPY; SMALL-INTESTINE; FEASIBILITY; EXPERIENCE; DISEASE; SAFETY;
D O I
10.1016/j.gie.2010.07.045
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Until now, the insertion depth of the enteroscope during double-balloon enteroscopy (DBE) could only be estimated. However, the currently available methods have limitations, and development of newer, simple, and accurate modalities is needed. Objective: To evaluate the accuracy of a novel method for evaluation of enteroscope insertion depth during DBE. Design: Prospective, single-center cohort study. Setting: Tertiary referral university hospital. Patients: Fifty-one patients who had lesions found during 41 antegrade and 10 retrograde DBEs and treated by surgery were enrolled in this study. Interventions: The length of the ligament of Treitz/ileocecal valve lesion was estimated by adding the forward enteroscope length during each cycle of passage and by calculating the overtube insertion length (every 5 cm of overtube advancement means 40 cm of enteroscope advancement based on preliminary observations) during DBE, respectively, and was evaluated at surgery. Main Outcome Measurements: The length from the ligament of Treitz/ileocecal valve to the lesion. Results: Surgical evaluation was used as the standard. Regardless of insertion route, the mean difference from surgery in evaluation of enteroscope insertion length between using the enteroscope method and the overtube method was 19 cm (range 0-50 cm) and 17 cm (range 0-60 cm), respectively (P > .05). Limitations: Small number of patients with a case series study design. Conclusions: Calculating the length of the overtube passage is accurate, and it is simple to estimate the insertion depth of the enteroscope during DBE, which is useful in clinical practice. (Gastrointest Endosc 2010;72:999-1005.)
引用
收藏
页码:999 / 1005
页数:7
相关论文
共 26 条
  • [1] New balloon-guided technique for deep small-intestine endoscopy using standard endoscopes
    Adler, S. N.
    Bjarnasonz, I.
    Metzger, Y. C.
    [J]. ENDOSCOPY, 2008, 40 (06) : 502 - 505
  • [2] The Spiral Enteroscopy experience in 101 consecutive patients: Safety and efficacy using the discovery SB
    Akerman, Paul a.
    Cantero, Daniel
    Avila, Jose
    Pangtay, Jesus
    Agrawal, Deepak
    [J]. GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB92 - AB93
  • [3] Does the insertion depth in push enteroscopy depend on the working length of the enteroscope?
    Benz, C
    Jakobs, R
    Riemann, JF
    [J]. ENDOSCOPY, 2002, 34 (07) : 543 - 545
  • [4] The European experience with double-balloon enteroscopy: indications, methodology, safety, and clinical impact
    Di Caro, S
    May, A
    Heine, DGN
    Fini, L
    Landi, B
    Petruzziello, L
    Cellier, C
    Mulder, CJ
    Costamagna, G
    Ell, C
    Gasbarrini, A
    [J]. GASTROINTESTINAL ENDOSCOPY, 2005, 62 (04) : 545 - 550
  • [5] Push-and-pull enteroscopy in the small bowel using the double-balloon technique: Results of a prospective European Multicenter study
    Ell, C
    May, A
    Nachbar, L
    Cellier, C
    Landi, B
    di Caro, S
    Gasbarrini, A
    [J]. ENDOSCOPY, 2005, 37 (07) : 613 - 616
  • [6] Balloon-assisted enteroscopy: technology and troubleshooting
    Gerson, Lauren B.
    Flodin, Jason T.
    Miyabayashi, Kenichi
    [J]. GASTROINTESTINAL ENDOSCOPY, 2008, 68 (06) : 1158 - 1167
  • [7] A prospective study comparing video capsule endoscopy with double-balloon enteroscopy in patients with obscure gastrointestinal bleeding
    Hadithi, M
    Heine, GDN
    Jacobs, MAJM
    von Bodegraven, AA
    Mulder, CJJ
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (01) : 52 - 57
  • [8] The value of double-balloon enteroscopy in patients with refractory celiac disease
    Hadithi, Muhammed
    Al-toma, Abdulbaqi
    Oudejans, Joost
    van Bodegraven, Adriaan A.
    Mulder, Chris J.
    Jacobs, Maarten
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 (05) : 987 - 996
  • [9] Balloon-assisted enteroscopy using a single-balloon technique
    Hartmann, D.
    Eickhoff, A.
    Tamm, R.
    Riemann, J. F.
    [J]. ENDOSCOPY, 2007, 39 : E276 - E276
  • [10] Wireless capsule endoscopy
    Iddan, G
    Meron, G
    Glukhovsky, A
    Swain, P
    [J]. NATURE, 2000, 405 (6785) : 417 - 417