Study on AC artificial-contaminated flashover performance of various types of insulators

被引:65
|
作者
Jiang, Xingliang [1 ]
Yuan, Jihe [1 ]
Zhang, Zhijin [1 ]
Hu, Jianlin [1 ]
Sun, Caixin [1 ]
机构
[1] Chongqing Univ, Coll Elect Engn, Key Lab High Voltage & Elect, New Technol Minist Educ, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
rho ESDD; rho NSDD; ac; artificial pollution test; flashover performance; insulator; shape;
D O I
10.1109/TPWRD.2007.899760
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Artificial pollution tests have been carried out to study ac flashover performances of various types of porcelain, glass, and polymeric insulators in this paper. The experimental results show that the polluted flashover voltage U-f is affected by equivalent salt deposit density rho(ESDD) and nonsoluble deposit density rho(NSDD), the influences of which are independent of each other. Based on the analyses of the flashover voltages, the correction formulas of the flashover voltages U-f of various insulators at various PESDD and rho(NSDD) levels are pointed out. The experimental results also show that there is a distinct difference among the flashover voltages of various types of polluted insulators. At the same pollution degree, the antipollution performance of the fog-type glass insulator is better than those of the outer-rib porcelain insulators. In terms of the effectiveness of creepage distance of insulators, the antipollution performance of polymeric insulators is superior to those of porcelain and glass insulators.
引用
收藏
页码:2567 / 2574
页数:8
相关论文
共 50 条
  • [31] AC and DC pollution flashover performance of multiple parallel suspension insulators
    Zhang, Chuyan
    Wang, Liming
    Zhou, Jun
    Zhang, Junguang
    Zhao, Chenlong
    Guan, Zhicheng
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (11): : 3357 - 3364
  • [32] Comparison on AC artificial pollution flashover performance and valid coefficient of creepage distance between porcelain and glass insulators
    Key Laboratory of High Voltage and Electrical New Technology, Chongqing University, Chongqing 400044, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 9 (6-10):
  • [33] AC Flashover Performance of Porcelain, Glass and Polymeric Insulators at High Altitudes
    Guo, Yujun
    Jiang, Xingliang
    Sree, V. Gowri
    Sundararajan, Raji
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 484 - 487
  • [34] Comparison on ac icing flashover performance of porcelain, glass, and composite insulators
    Jiang, Xingliang
    Xiang, Ze
    Zhang, Zhijin
    Hu, Jianlin
    Hu, Qin
    Shu, Lichun
    Cold Regions Science and Technology, 2014, 100 : 1 - 7
  • [35] AC flashover performance of natural iced insulators in high altitude regions
    Shu, LC
    Jiang, XL
    Mei, BX
    Hu, Q
    Yang, Q
    PROCEEDINGS OF THE FOURTEENTH (2004) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1, 2004, : 940 - 944
  • [36] Modeling Flashover of AC Outdoor Insulators under Contaminated Conditions with Dry Band Formation and Arcing
    Bo, L.
    Gorur, R. S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (03) : 1037 - 1043
  • [37] Investigation of Natural and Artificial Contamination on Various Types of Insulators
    Vinothkumar, R.
    Kannayeram, G.
    Shunmugalakshmi, G.
    2015 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION, EMBEDDED AND COMMUNICATION SYSTEMS (ICIIECS), 2015,
  • [38] Flashover Performance of Polluted Composite Insulators Under AC and Hybrid AC/DC Field Stress
    Saadati, Hassan
    Werle, Peter
    Gockenbach, Ernst
    Borsi, Hossein
    Seifert, Jens Martin
    2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 170 - 173
  • [39] Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 WUHV AC transmission lines
    Hu, Jianlin
    Sun, Caixin
    Jiang, Xingliang
    Zhang, Zhijin
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) : 1347 - 1356
  • [40] AC flashover performance of glass insulators covered with ice or snow at natural station
    Xiang, Ze
    Jiang, Xingliang
    Zhang, Zhijin
    Hu, Jianlin
    Jin, Xi
    Guo, Yujun
    Xiang, Z. (xiangze1987@163.com), 1600, Science Press (40): : 1345 - 1350