Three-Dimensional Functional Impingement in Total Hip Arthroplasty: A Biomechanical Analysis

被引:8
作者
Debbi, Eytan M. [1 ]
Gonzalez, Fernando J. Quevedo [2 ]
Jerabek, Seth A. [1 ]
Wright, Timothy M. [2 ]
Vigdorchik, Jonathan M. [1 ]
机构
[1] Hosp Special Surg, Dept Orthopaed Surg Adult Reconstruct & Joint Rep, 535 E 70th St, New York, NY 10021 USA
[2] Hosp Special Surg, Dept Biomech, 535 E 70th St, New York, NY 10021 USA
关键词
impingement; offset; total hip arthroplasty; 3D model; dislocation; FEMORAL OFFSET; BONY IMPINGEMENT; MOTION; RANGE;
D O I
10.1016/j.arth.2022.02.112
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although component offset can affect impingement after total hip arthroplasty, the exact impact is unclear. Evaluation of offset on an anterior-posterior pelvic radiograph is different than evaluation in functional positions of impingement, namely flexion/internal rotation and extension/external rotation. We quantified the effect of acetabular (cup/liner) vs femoral (head/stem) offsets on changes in range of motion to extra-prosthetic impingement in these 2 impingement-prone functional positions. Methods: We retrospectively identified 16 total hip arthroplasty patients (age 61.5 +/- 12.1 years, body mass index 28.3 +/- 4.9 kg/m(2)) with preoperative and postoperative computerized tomography scans. To eliminate metal artifact, femoral and pelvic 3-dimensional models were created using preoperative scans aligned with postoperative scans, and 3-dimensional scanned implant models were used to reproduce clinical implantation. We tested +/- 5 mm acetabular cup, acetabular liner, femoral stem, and femoral head offsets. Maximum range of motion (ROM) to bone-bone impingement was calculated for internal rotation at 90 degrees flexion and external rotation at 10 degrees extension. Results: In all cases, increased offset increased ROM to impingement, and vice versa. During internal rotation at 90 degrees flexion, +/- 5 mm liner offset had the greatest impact on ROM (+9 degrees/-10 degrees), followed by cup (+8 degrees/-9 degrees), head (+5 degrees/-7 degrees), and stem (+3 degrees/-5 degrees) offset. During external rotation at 10 degrees extension, +/- 5 mm cup offset had the greatest impact on ROM (+10 degrees/-10 degrees), followed by liner (+9 degrees/-9 degrees), head (+7 degrees/-8 degrees), and stem (+4 degrees/-4 degrees) offset. However, no statistically significant differences were found in the changes to ROM in flexion obtained through cup and liner offsets, the changes to ROM in extension obtained through liner and head offsets, and the changes to ROM in extension obtained through increasing stem and head offsets. Conclusion: Increasing offset by any method reduces impingement. Center-of-rotation offset changes via acetabular cup or liner have the greatest impact on extra-prosthetic impingement. (C) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:S678 / S684
页数:7
相关论文
共 16 条
[1]   Impingement in total hip replacement: mechanisms and consequences [J].
Brown, Thomas D. ;
Callaghan, John J. .
CURRENT ORTHOPAEDICS, 2008, 22 (06) :376-391
[2]   Determining and Achieving Target Limb Length and Offset in Total Hip Arthroplasty Using Intraoperative Digital Radiography [J].
Debbi, Eytan M. ;
Rajaee, Sean S. ;
Mayeda, Brian F. ;
Penenberg, Brad L. .
JOURNAL OF ARTHROPLASTY, 2020, 35 (03) :779-785
[3]   Wear Rates With Large Metal and Ceramic Heads on a Second Generation Highly Cross-Linked Polyethylene at Mean 6-Year Follow-Up [J].
Gaudiani, Michael A. ;
White, Peter B. ;
Ghazi, Narges ;
Ranawat, Amar S. ;
Ranawat, Chitranjan S. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (02) :590-594
[4]   The Lawrence D. Dorr Surgical Techniques & Technologies Award: Why Are Contemporary Revision Total Hip Arthroplasties Failing? An Analysis of 2500 Cases [J].
Goldman, Ashton H. ;
Sierra, Rafael J. ;
Trousdale, Robert T. ;
Lewallen, David G. ;
Berry, Daniel J. ;
Abdel, Matthew P. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (07) :S11-S16
[5]   The Effect of a Degenerative Spine and Adverse Pelvic Mobility on Prosthetic Impingement in Patients Undergoing Total Hip Arthroplasty [J].
Gu, Yolanda M. ;
Kim, Woosung ;
Pierrepont, Jim W. ;
Li, Qing ;
Shimmin, Andrew J. .
JOURNAL OF ARTHROPLASTY, 2021, 36 (07) :2523-2529
[6]   Current Epidemiology of Revision Total Hip Arthroplasty in the United States: National Inpatient Sample 2009 to 2013 [J].
Gwam, Chukwuweike U. ;
Mistry, Jaydev B. ;
Mohamed, Nequesha S. ;
Thomas, Melbin ;
Bigart, Kevin C. ;
Mont, Michael A. ;
Delanois, Ronald E. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (07) :2088-2092
[7]   Excessive femoral offset does not affect the range of motion after total hip arthroplasty [J].
Hayashi, Shinya ;
Nishiyama, Takayuki ;
Fujishiro, Takaaki ;
Hashimoto, Shingo ;
Kanzaki, Noriyuki ;
Nishida, Kotaro ;
Kuroda, Ryosuke ;
Kurosaka, Masahiro .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (07) :1233-1237
[8]   Polyethylene Wear is Related to Patient-specific Contact Stress in THA [J].
Kosak, Robert ;
Kralj-Iglic, Veronika ;
Iglic, Ales ;
Daniel, Matej .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) :3415-3422
[9]   Effects of the Femoral Offset and the Head Size on the Safe Range of Motion in Total Hip Arthroplasty [J].
Matsushita, Akinobu ;
Nakashima, Yasuharu ;
Jingushi, Seiya ;
Yamamoto, Takuaki ;
Kuraoka, Akio ;
Iwamoto, Yukihide .
JOURNAL OF ARTHROPLASTY, 2009, 24 (04) :646-651
[10]   Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematics [J].
Renkawitz, Tobias ;
Weber, Tim ;
Dullien, Silvia ;
Woerner, Michael ;
Dendorfer, Sebastian ;
Grifka, Joachim ;
Weber, Markus .
GAIT & POSTURE, 2016, 49 :196-201