Comparing micro-scale weather data to building energy consumption in Singapore

被引:45
作者
Liu, Yuezhong [1 ]
Stouffs, Rudi [1 ]
Tablada, Abel [1 ]
Wong, Nyuk Hien [1 ]
Zhang, Ji [1 ]
机构
[1] Natl Univ Singapore, Singapore, Singapore
关键词
TMY; UHI; Sandia method; Energy performance; TYPICAL METEOROLOGICAL YEAR; URBAN HEAT-ISLAND; HONG-KONG; GENERATION; SIMULATION; CITY; TEMPERATURE; NICOSIA; CLIMATE; CYPRUS;
D O I
10.1016/j.enbuild.2016.11.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Weather data plays an important role for energy performance assessment in the design of buildings and urban environments. Many researches have been carried out to generate and analyse various weather files for different simulation platforms. However, investigations have been lacking in the development of weather files reflecting on urban texture variables that account for urban heat island (UHI) problems. The objective of this research is to demonstrate the importance for creating a micro-scale typical meteorological year (TMY) weather file that is based on actual urban texture values. A method is demonstrated to generate new TMY weather files for different micro-scale areas in Singapore based on recent years' weather data. A comparative impact analysis is made between using the current weather file and the new weather files in terms of energy consumption. Based on the results, the dry bulb temperature of the new TMY is 1-2 degrees C higher, while the energy consumption prediction increased from 3.25% to 11%. Comparing with actual energy consumption figures the results show to be closer than when using the old TMY. Hence the new weather files will be more credible than the original TMY for energy performance simulation in the design process. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:776 / 791
页数:16
相关论文
共 59 条
[1]   COMPUTING THE FRECHET DISTANCE BETWEEN 2 POLYGONAL CURVES [J].
ALT, H ;
GODAU, M .
INTERNATIONAL JOURNAL OF COMPUTATIONAL GEOMETRY & APPLICATIONS, 1995, 5 (1-2) :75-91
[2]  
[Anonymous], 2004, WORLD METEOROLOG ORG
[3]  
[Anonymous], 2013, EnergyPlus Engineering Reference
[4]  
[Anonymous], 2015, AUT SUST WORKSH AUT
[5]   The urban weather generator [J].
Bueno, Bruno ;
Norford, Leslie ;
Hidalgo, Julia ;
Pigeon, Gregoire .
JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2013, 6 (04) :269-281
[6]  
Building and Construction Authority, 2012, BCA GREEN MARK CERT
[7]   Developing a modified typical meteorological year weather file for Hong Kong taking into account the urban heat island effect [J].
Chan, A. L. S. .
BUILDING AND ENVIRONMENT, 2011, 46 (12) :2434-2441
[8]   Generation of a typical meteorological year for Hong Kong [J].
Chan, ALS ;
Chow, TT ;
Fong, SKF ;
Lin, JZ .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (01) :87-96
[9]   Energy performance of residential buildings in Singapore [J].
Chua, K. J. ;
Chou, S. K. .
ENERGY, 2010, 35 (02) :667-678
[10]  
Clark G., 1978, 2 NAT PASS SOL C AS, P675