Sensitive and fast T1 mapping based on two inversion recovery images and a reference image

被引:13
作者
Jahng, GH [1 ]
Stables, L [1 ]
Ebel, A [1 ]
Matson, GB [1 ]
Meyerhoff, DJ [1 ]
Weiner, MW [1 ]
Schuff, N [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94121 USA
关键词
MRI; spin lattice relaxation time; inversion recovery; error propagation;
D O I
10.1118/1.1915014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We developed a fast method to obtain T-1 relaxation maps in magnetic resonance imaging (MRI) based on two inversion recovery acquisitions and a reference acquisition, while maintaining high sensitivity by utilizing the full dynamic range of the MRI signal. Optimal inversion times for estimating T-1 in the human brain were predicted using standard error propagation theory. In vivo measurements on nine healthy volunteers yielded T-1 values of 1094 +/- 18 ms in gray matter and 746 +/- 40 ms in white matter, in reasonable agreement with literature values using conventional approaches. The proposed method should be useful for clinical studies because the T-1 maps can be obtained within a few seconds. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1524 / 1528
页数:5
相关论文
共 18 条
  • [1] Establishing norms for age-related changes in proton T-1 of human brain tissue in vivo
    Cho, S
    Jones, D
    Reddick, WE
    Ogg, RJ
    Steen, RG
    [J]. MAGNETIC RESONANCE IMAGING, 1997, 15 (10) : 1133 - 1143
  • [2] A COMPARISON OF ONE-SHOT AND RECOVERY METHODS IN T1-IMAGING
    CRAWLEY, AP
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) : 23 - 34
  • [3] DICKINSON RJ, 1986, J COMPUT ASSIST TOMO, V10, P468
  • [4] Haacke M.E., 1999, MAGNETIC RESONANCE I, Vfirst, P51
  • [5] Two-point method for T2 estimation with optimized gradient-echo sequence
    Imran, J
    Langevin, F
    Saint-James, H
    [J]. MAGNETIC RESONANCE IMAGING, 1999, 17 (09) : 1347 - 1356
  • [6] Improved perfusion-weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions
    Jahng, GH
    Zhu, XP
    Matson, GB
    Weiner, MW
    Schuff, N
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 307 - 314
  • [7] ACCURATE T(1) DETERMINATION FROM INVERSION-RECOVERY IMAGES - APPLICATION TO HUMAN BRAIN AT 4-TESLA
    KIM, SG
    HU, XP
    UGURBIL, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) : 445 - 449
  • [8] Kingsley PB, 1999, CONCEPT MAGNETIC RES, V11, P243, DOI 10.1002/(SICI)1099-0534(1999)11:4<243::AID-CMR5>3.3.CO
  • [9] 2-3
  • [10] Kingsley PB, 1999, CONCEPT MAGNETIC RES, V11, P29, DOI 10.1002/(SICI)1099-0534(1999)11:1<29::AID-CMR2>3.0.CO