Intravoxel Incoherent Motion Diffusion-weighted MR Imaging of the Liver: Effect of Triggering Methods on Regional Variability and Measurement Repeatability of Quantitative Parameters

被引:103
作者
Lee, Yedaun [1 ,2 ]
Lee, Seung Soo [1 ,2 ]
Kim, Namkug [1 ,2 ]
Kim, Eunki [1 ,2 ]
Kim, Yeong Jae [1 ,2 ]
Yun, Sung-Cheol [3 ]
Kuehn, Bernd [4 ]
Kim, In Seong [5 ]
Park, Seong Ho [1 ,2 ]
Kim, So Yeon [1 ,2 ]
Lee, Moon-Gyu [1 ,2 ]
机构
[1] Univ Ulsan, Coll Med, Dept Radiol, Asan Med Ctr, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Res Inst Radiol, Asan Med Ctr, Seoul 138736, South Korea
[3] Univ Ulsan, Coll Med, Dept Clin Epidemiol & Biosta, Asan Med Ctr, Seoul 138736, South Korea
[4] Siemens AG, Healthcare Oncol Applicat Dev, Erlangen, Germany
[5] Siemens Healthcare Korea, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
COEFFICIENT; PERFUSION; REPRODUCIBILITY; METASTASES; CHALLENGES; BIOMARKERS; CIRRHOSIS; ABDOMEN; PILOT;
D O I
10.1148/radiol.14140759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the influence of triggering methods for diffusion-weighted imaging (DWI) on apparent diffusion coefficient (ADC) and intravoxel incoherent motion (IVIM) parameters in the liver, as well as regional variability and measurement repeatability. Materials and Methods: In this institutional review board-approved prospective study, 12 healthy volunteers (six women, six men; mean age, 30 years) underwent 1.5-T DWI of the liver by using nine b values twice with free breathing (FB) without triggering (mean acquisition time +/- standard deviation, 3.7 minutes +/- 0), respiratory triggering (RT) (mean acquisition time, 6.8 minutes +/- 1.4), and echocardiography triggering (ET) (mean acquisition time, 8.3 minutes +/- 2.0) after providing written informed consent. ADC and IVIM parameters, including pure diffusion coefficient (D), perfusion fraction (f), and perfusion-related diffusion coefficient (D*), were measured by using 15 regions of interest (ROIs). Regional variability of ADC and IVIM parameters and measurement repeatability were evaluated by using the coefficient of variation (CV) across ROIs and within-subject CV, respectively. Results: ET DWI (range of CV across ROIs, 6.69%-20.0%) resulted in significantly decreased regional variability of ADC, D, and f, compared with FB DWI (13.86%-35.8%) and RT DWI (15.15%-35.91%, P <= .049). ET DWI showed better repeatability of ADC measurement (within-subject CV range, 3.17%-4.12% for ET DWI; 4.15%-4.74% for FB DWI; and 2.33%-6.96% for RT DWI), D (4.05%-5.34% for ET DWI, 4.11%-12.51% for FB DWI, and 3.19%-16.17% for RT DWI), and f (7.6%-9.86% for ET DWI, 13.83%-16.81% for FB DWI, and 10.05%-12.10% for RT DWI), compared with FB DWI and RT DWI, with significant differences in within-subject CV for D in the left hepatic lobe compared with RT DWI (P = .023) and for f compared with FB DWI (P <= .032). For all three imaging techniques, D* showed the worst repeatability (within-subject CV, 57.05%-156.61%) among ADC and IVIM parameters. Conclusion: ET DWI is more effective for decreasing regional variability of ADC and IVIM parameters than FB DWI or RT DWI; it may improve measurement repeatability by reducing cardiac motion-induced measurement error. (C) RSNA, 2014
引用
收藏
页码:405 / 415
页数:11
相关论文
共 31 条
[1]   Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion-weighted MR imaging in normal liver and metastases [J].
Andreou, A. ;
Koh, D. M. ;
Collins, D. J. ;
Blackledge, M. ;
Wallace, T. ;
Leach, M. O. ;
Orton, M. R. .
EUROPEAN RADIOLOGY, 2013, 23 (02) :428-434
[2]  
[Anonymous], DCE MRI QUANT PROF Q
[3]   Applications of the Repeatability of Quantitative Imaging Biomarkers: A Review of Statistical Analysis of Repeat Data Sets [J].
Barnhart, Huiman X. ;
Barboriak, Daniel P. .
TRANSLATIONAL ONCOLOGY, 2009, 2 (04) :231-235
[4]   Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique [J].
Bruegel, Melanie ;
Holzapfel, Konstantin ;
Gaa, Jochen ;
Woertler, Klaus ;
Waldt, Simone ;
Kiefer, Berthold ;
Stemmer, Alto ;
Ganter, Carl ;
Rummeny, Ernst J. .
EUROPEAN RADIOLOGY, 2008, 18 (03) :477-485
[5]  
Cohen AD, 2014, MAGN RESON MED
[6]   Apparent diffusion coefficient: Potential imaging biomarker for prediction and early detection of response to chemotherapy in hepatic metastases [J].
Cui, Yong ;
Zhang, Xiao-Peng ;
Sun, Ying-Shi ;
Tang, Lei ;
Shen, Lin .
RADIOLOGY, 2008, 248 (03) :894-900
[7]  
Davison A.G., 1997, Bootstrap Methods and Their Application
[8]   Determination of Malignancy and Characterization of Hepatic Tumor Type With Diffusion-Weighted Magnetic Resonance Imaging Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion-Derived Measurements [J].
Doblas, Sabrina ;
Wagner, Mathilde ;
Leitao, Helena S. ;
Daire, Jean-Luc ;
Sinkus, Ralph ;
Vilgrain, Valerie ;
Van Beers, Bernard E. .
INVESTIGATIVE RADIOLOGY, 2013, 48 (10) :722-728
[9]   Diffusion-weighted Imaging of the Liver with Multiple b Values: Effect of Diffusion Gradient Polarity and Breathing Acquisition on Image Quality and Intravoxel Incoherent Motion Parameters-A Pilot Study [J].
Dyvorne, Hadrien A. ;
Galea, Nicola ;
Nevers, Thomas ;
Fiel, M. Isabel ;
Carpenter, David ;
Wong, Edmund ;
Orton, Matthew ;
de Oliveira, Andre ;
Feiweier, Thorsten ;
Vachon, Marie-Louise ;
Babb, James S. ;
Taouli, Bachir .
RADIOLOGY, 2013, 266 (03) :920-929
[10]   QT interval: How to measure it and what is "normal" [J].
Goldenberg, I ;
Moss, AJ ;
Zareba, W .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (03) :333-336