Modeling of Transmission Characteristics Across a Cable-Conduit System

被引:118
作者
Agrawal, Varun [1 ]
Peine, William J. [1 ]
Yao, Bin [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47906 USA
基金
美国国家科学基金会;
关键词
Cable-conduit actuation; cable compliance; friction; pull-pull configuration; surgical robot;
D O I
10.1109/TRO.2010.2064014
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Many robotic systems, like surgical robots, robotic hands, and exoskeleton robots, use cable passing through conduits to actuate remote instruments. Cable actuation simplifies the design and allows the actuator to be located at a convenient location, away from the end effector. However, nonlinear frictions between the cable and the conduit account for major losses in tension transmission across the cable, and a model is needed to characterize their effects in order to analyze and compensate for them. Although some models have been proposed in the literature, they are lumped parameter based and restricted to the very special case of a single cable with constant conduit curvature and constant pretension across the cable only. This paper proposes a mathematically rigorous distributed parameter model for cable-conduit actuation with any curvature and initial tension profile across the cable. The model, which is described by a set of partial differential equations in the continuous time-domain, is also discretized for the effective numerical simulation of the cable motion and tension transmission across the cable. Unlike the existing lumped-parameter-based models, the resultant discretized model enables one to accurately simulate the partial-moving/partial-sticking cable motion of the cable-conduit actuation with any curvature and initial tension profile. The model is further extended to cable-conduit actuation in pull-pull configuration using a pair of cables. Various simulations results are presented to reveal the unique phenomena like backlash, cable slacking, interaction between the two cables, and other nonlinear behaviors associated with the cable conduits in pull-pull configuration. These results are verified by experiments using two dc motors coupled with a cable-conduit pair. The experimental setup has been prepared to emulate a typical cable-actuated robotic system. Experimental results are compared with the simulations and various implications are discussed.
引用
收藏
页码:914 / 924
页数:11
相关论文
共 17 条
  • [1] AGRAWAL V, 2008, P IEEE INT C ROB AUT, P3407
  • [2] FANZINO RJ, 2003, SURG CLIN N AM, V83, P1317
  • [3] Guthart G. S., 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065), P618, DOI 10.1109/ROBOT.2000.844121
  • [4] INPUT-DEPENDENT STABILITY OF JOINT TORQUE CONTROL OF TENDON-DRIVEN ROBOT HANDS
    KANEKO, M
    PAETSCH, W
    TOLLE, H
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1992, 39 (02) : 96 - 104
  • [5] Kaneko M., 1991, 91 ICAR. Fifth International Conference on Advanced Robotics. Robots in Unstructured Environments (Cat. No.91TH0376-4), P827, DOI 10.1109/ICAR.1991.240572
  • [6] KANEKO M, 1991, 1991 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-3, P1028, DOI 10.1109/ROBOT.1991.131727
  • [7] Kassim I, 2003, IEEE INT CONF ROBOT, P1086
  • [8] Lotti F, 2005, IEEE INT CONF ROBOT, P4488
  • [9] Lotti F, 2002, 2002 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-3, PROCEEDINGS, P1687, DOI 10.1109/IRDS.2002.1043998
  • [10] Nahvi A., 1994, P IEEE INT C INT ROB, V1, P202