Calculation of the mean pressure with less delay for real-time clinical monitoring

被引:0
|
作者
Ellis, Tim [1 ]
McNames, James [1 ]
Goldstein, Brahm [2 ]
机构
[1] Portland State Univ, Biomed Signal Proc Lab, Elect & Comp Engn, Portland, OR 97207 USA
[2] Oregon Hlth & Sci Univ, Div Pediatr Crit Care, Complex Syst Lab, Portland, OR 97207 USA
来源
2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15 | 2006年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The mean of cardiovascular pressure signals is an important metric in patient monitoring applications for many types of diseases and injuries. It is typically calculated with a moving- average of 3-8s of the pulsatile signal. This method of calculating the mean introduces a delay of 1.5-4s. We demonstrate that an FIR filter with coefficients calculated with a least squares error (LSE) estimator can reduce this delay without a clinically significant impact on the accuracy of the displayed signal. Preliminary results with intracranial pressure signals show that the delay can be completely eliminated with a maximum root-mean-square error of approximately 1 mmHg. Reduction or elimination of this delay could permit patient monitors to display the mean in real time and permit clinicians to respond to acute events more rapidly.
引用
收藏
页码:2439 / +
页数:2
相关论文
共 50 条
  • [41] REAL-TIME EXECUTION MONITORING
    PLATTNER, B
    IEEE TRANSACTIONS ON SOFTWARE ENGINEERING, 1984, 10 (06) : 756 - 764
  • [42] Monitoring of real-time properties
    Bauer, Andreas
    Leucker, Martin
    Schallhart, Christian
    FSTTCS 2006: FOUNDATIONS OF SOFTWARE TECHNOLOGY AND THEORETICAL COMPUTER SCIENCE, PROCEEDINGS, 2006, 4337 : 260 - +
  • [43] Real-time monitoring of sediments
    Sequoia Scientific Inc., Bellevue, WA, United States
    Int. Water Power Dam Constr., 2012, 5 (18-19):
  • [44] Sound pressure level real-time monitoring of outdoor directional noise
    Chen, Yong
    Wu, Ming
    Lu, Ling
    Fang, Xing
    Yang, Jun
    APPLIED ACOUSTICS, 2023, 202
  • [45] Real-Time Monitoring of Blood Flow and Intravesical Pressure in the Rat Bladder
    Saito, Motoaki
    Ohmasa, Fumiya
    Tsounapi, Panagiota
    Inoue, Seiya
    Kinoshita, Yukako
    Dimitriadis, Fotios
    Satoh, Keisuke
    LUTS-LOWER URINARY TRACT SYMPTOMS, 2011, 3 (02) : 76 - 78
  • [46] Testbed for Real-time Monitoring of Leak in Low Pressure Gas Pipeline
    Mishra, Himanshu
    Karkulali, Pugalenthi
    Ukil, Abhisek
    Dauwels, Justin
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 459 - 462
  • [47] Gas density sensor for real-time monitoring in a high pressure reactor
    Sell, J. K.
    Niedermayer, A. O.
    Babik, S.
    Jakoby, B.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 108 - +
  • [48] Improvement of longwall operation using real-time shield pressure monitoring
    Deb, D
    SITE CHARACTERISATION PRACTICE, 2000, : 475 - 481
  • [49] Development of a System for Real-Time Monitoring of Pressure, Temperature, and Humidity in Casts
    Tuan, Chiu-Ching
    Lu, Chi-Heng
    Wu, Yi-Chao
    Yeh, Wen-Ling
    Chen, Mei-Chuan
    Lee, Tsair-Fwu
    Chen, Yu-Jing
    Kao, Hsuan-Kai
    SENSORS, 2019, 19 (10):
  • [50] LoRa Pore Pressure Probe for Real-Time Coastal Environment Monitoring
    Hagh, Soheyl Faghir
    Amngostar, Parmida
    Burns, Dylan
    Molaei, Saba
    Gallant, Aaron
    Huston, Dryver
    Xia, Tian
    IEEE SENSORS JOURNAL, 2024, 24 (23) : 39751 - 39758