Calculation of the mean pressure with less delay for real-time clinical monitoring

被引:0
作者
Ellis, Tim [1 ]
McNames, James [1 ]
Goldstein, Brahm [2 ]
机构
[1] Portland State Univ, Biomed Signal Proc Lab, Elect & Comp Engn, Portland, OR 97207 USA
[2] Oregon Hlth & Sci Univ, Div Pediatr Crit Care, Complex Syst Lab, Portland, OR 97207 USA
来源
2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15 | 2006年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The mean of cardiovascular pressure signals is an important metric in patient monitoring applications for many types of diseases and injuries. It is typically calculated with a moving- average of 3-8s of the pulsatile signal. This method of calculating the mean introduces a delay of 1.5-4s. We demonstrate that an FIR filter with coefficients calculated with a least squares error (LSE) estimator can reduce this delay without a clinically significant impact on the accuracy of the displayed signal. Preliminary results with intracranial pressure signals show that the delay can be completely eliminated with a maximum root-mean-square error of approximately 1 mmHg. Reduction or elimination of this delay could permit patient monitors to display the mean in real time and permit clinicians to respond to acute events more rapidly.
引用
收藏
页码:2439 / +
页数:2
相关论文
共 50 条
  • [21] High-pressure balloon catheter for real-time pressure monitoring in the Esophagus
    Kwan, KY
    Kaler, KVIS
    Mintchev, M
    ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS, 2002, : 1211 - 1214
  • [22] Wireless Less-Invasive Blood Pressure Sensing Microsystem for Small Laboratory Animal In Vivo Real-Time Monitoring
    Cong, Peng
    Ko, Wen H.
    Young, Darrin I.
    INSS 2008: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON NETWORKED SENSING SYSTEMS, 2008, : 80 - 86
  • [23] Real-time continuous glucose monitoring: proven clinical indiciations
    Gomez Peralta, Fernando
    Abreu Padin, Cristina
    AVANCES EN DIABETOLOGIA, 2011, 27 (06): : 198 - 203
  • [24] ADVANCED CLINICAL MONITORING - CONSIDERATIONS FOR REAL-TIME HEMODYNAMIC DIAGNOSTICS
    GOLDMAN, JM
    CORDOVA, MJ
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1994, : 752 - 755
  • [25] Novel application of the magnetostrictive delay lines for real-time monitoring of the ceramic components
    Szewczyk, Roman
    Salach, Jacek
    Bienkowski, Adam
    Olszyna, Andrzej
    Kostecki, Marek
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2008, 320 (20) : E971 - E973
  • [26] Real-Time Delay Estimation Based on Delay History
    Ibrahim, Rouba
    Whitt, Ward
    M&SOM-MANUFACTURING & SERVICE OPERATIONS MANAGEMENT, 2009, 11 (03) : 397 - 415
  • [27] Real-Time Calculation Method of DC Voltage and Current to Eliminate the Influence of Signal Delay
    Yin, Chunya
    Li, Fengting
    IEEE ACCESS, 2020, 8 : 157168 - 157176
  • [28] Implementation of quadrature based RMS calculation on real-time power monitoring systems
    Hussain, Syed A.
    Zaro, Fouad R.
    Abido, Mohammed A.
    2013 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2013, : 213 - 217
  • [29] Real-Time Berth Monitoring
    Mech, Konrad
    SEA TECHNOLOGY, 2019, 60 (03) : 15 - 17
  • [30] Real-time EGNOS Monitoring
    Pfleger, Michal
    Spacek, Josef
    PROCEEDINGS ELMAR-2010, 2010, : 425 - 428