Calculation of the mean pressure with less delay for real-time clinical monitoring

被引:0
作者
Ellis, Tim [1 ]
McNames, James [1 ]
Goldstein, Brahm [2 ]
机构
[1] Portland State Univ, Biomed Signal Proc Lab, Elect & Comp Engn, Portland, OR 97207 USA
[2] Oregon Hlth & Sci Univ, Div Pediatr Crit Care, Complex Syst Lab, Portland, OR 97207 USA
来源
2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15 | 2006年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The mean of cardiovascular pressure signals is an important metric in patient monitoring applications for many types of diseases and injuries. It is typically calculated with a moving- average of 3-8s of the pulsatile signal. This method of calculating the mean introduces a delay of 1.5-4s. We demonstrate that an FIR filter with coefficients calculated with a least squares error (LSE) estimator can reduce this delay without a clinically significant impact on the accuracy of the displayed signal. Preliminary results with intracranial pressure signals show that the delay can be completely eliminated with a maximum root-mean-square error of approximately 1 mmHg. Reduction or elimination of this delay could permit patient monitors to display the mean in real time and permit clinicians to respond to acute events more rapidly.
引用
收藏
页码:2439 / +
页数:2
相关论文
共 50 条
[21]   High-pressure balloon catheter for real-time pressure monitoring in the Esophagus [J].
Kwan, KY ;
Kaler, KVIS ;
Mintchev, M .
ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS, 2002, :1211-1214
[22]   Wireless Less-Invasive Blood Pressure Sensing Microsystem for Small Laboratory Animal In Vivo Real-Time Monitoring [J].
Cong, Peng ;
Ko, Wen H. ;
Young, Darrin I. .
INSS 2008: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON NETWORKED SENSING SYSTEMS, 2008, :80-86
[23]   Real-time continuous glucose monitoring: proven clinical indiciations [J].
Gomez Peralta, Fernando ;
Abreu Padin, Cristina .
AVANCES EN DIABETOLOGIA, 2011, 27 (06) :198-203
[24]   ADVANCED CLINICAL MONITORING - CONSIDERATIONS FOR REAL-TIME HEMODYNAMIC DIAGNOSTICS [J].
GOLDMAN, JM ;
CORDOVA, MJ .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1994, :752-755
[25]   Novel application of the magnetostrictive delay lines for real-time monitoring of the ceramic components [J].
Szewczyk, Roman ;
Salach, Jacek ;
Bienkowski, Adam ;
Olszyna, Andrzej ;
Kostecki, Marek .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2008, 320 (20) :E971-E973
[26]   Real-Time Calculation Method of DC Voltage and Current to Eliminate the Influence of Signal Delay [J].
Yin, Chunya ;
Li, Fengting .
IEEE ACCESS, 2020, 8 :157168-157176
[27]   Real-Time Delay Estimation Based on Delay History [J].
Ibrahim, Rouba ;
Whitt, Ward .
M&SOM-MANUFACTURING & SERVICE OPERATIONS MANAGEMENT, 2009, 11 (03) :397-415
[28]   Implementation of quadrature based RMS calculation on real-time power monitoring systems [J].
Hussain, Syed A. ;
Zaro, Fouad R. ;
Abido, Mohammed A. .
2013 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2013, :213-217
[29]   Real-Time Berth Monitoring [J].
Mech, Konrad .
SEA TECHNOLOGY, 2019, 60 (03) :15-17
[30]   Real-time EGNOS Monitoring [J].
Pfleger, Michal ;
Spacek, Josef .
PROCEEDINGS ELMAR-2010, 2010, :425-428