Beam Homogeneity Dependence on the Magnetic Filter Field at the IPP Test Facility MANITU

被引:23
作者
Franzen, P. [1 ]
Fantz, U. [1 ]
机构
[1] EURATOM, Max Planck Inst Plasmaphys, D-85740 Garching, Germany
来源
SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES | 2011年 / 1390卷
关键词
Neutral Beam Injection; ITER; negative ion source; RF source; COLLISIONS;
D O I
10.1063/1.3637401
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The homogeneity of the extracted current density from the large RF driven negative hydrogen ion sources of the ITER neutral beam system is a critical issue for the transmission of the negative ion beam through the accelerator and the beamline components. As a first test, the beam homogeneity at the IPP long pulse test facility MANITU is measured by means of the divergence and the stripping profiles obtained with a spatially resolved Doppler-shift spectroscopy system. Since MANITU is typically operating below the optimum perveance, an increase in the divergence corresponds to a lower local extracted negative ion current density if the extraction voltage is constant. The beam H-alpha Doppler-shift spectroscopy is a rather simple tool, as no absolute calibration - both for the wavelength and the emission - is necessary. Even no relative calibration of the different used lines of sight is necessary for divergence and stripping profiles as these quantities can be obtained by the line broadening of the Doppler-shifted peak and the ratio of the integral of the stripping peak to the integral of the Doppler-shifted peak, respectively. The paper describes the H-alpha MANITU Doppler-shift spectroscopy system which is now operating routinely and the evaluation methods of the divergence and the stripping profiles. Beam homogeneity measurements are presented for different extraction areas and magnetic filter field configurations both for Hydrogen and Deuterium operation; the results are compared with homogeneity measurements of the source plasma. The stripping loss measurements are compared with model calculations.
引用
收藏
页数:12
相关论文
共 18 条
[1]  
Barnett CF, 1990, ORNL6086VI, VI
[2]   Physical performance analysis and progress of the development of the negative ion RF source for the ITER NBI system [J].
Fantz, U. ;
Franzen, P. ;
Kraus, W. ;
Berger, M. ;
Christ-Koch, S. ;
Falter, H. ;
Froeschle, M. ;
Gutser, R. ;
Heinemann, B. ;
Martens, C. ;
McNeely, P. ;
Riedl, R. ;
Speth, E. ;
Staebler, A. ;
Wuenderlich, D. .
NUCLEAR FUSION, 2009, 49 (12)
[3]   Progress of the development of the IPP RF negative ion source for the ITER neutral beam system [J].
Franzen, P. ;
Falter, H. D. ;
Fantz, U. ;
Kraus, W. ;
Berger, M. ;
Christ-Koch, S. ;
Froeschle, M. ;
Gutser, R. ;
Heinemann, B. ;
Hilbert, S. ;
Leyer, S. ;
Martens, C. ;
McNeely, P. ;
Riedl, R. ;
Speth, E. ;
Wuenderlich, D. .
NUCLEAR FUSION, 2007, 47 (04) :264-270
[4]  
Franzen P, 2009, AIP CONF PROC, V1097, P451, DOI 10.1063/1.3112544
[5]   FORMATION OF EXCITED HYDROGEN-ATOMS IN ELECTRON DETACHMENT COLLISIONS BY 3-25 KEV H-IONS [J].
GEDDES, J ;
HILL, J ;
GILBODY, HB .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1981, 14 (24) :4837-4846
[6]  
Heinemann B., 2010, FUS ENG DES IN PRESS
[7]   Status of the ITER heating neutral beam system [J].
Hemsworth, R. ;
Decamps, H. ;
Graceffa, J. ;
Schunke, B. ;
Tanaka, M. ;
Dremel, M. ;
Tanga, A. ;
De Esch, H. P. L. ;
Geli, F. ;
Milnes, J. ;
Inoue, T. ;
Marcuzzi, D. ;
Sonato, P. ;
Zaccaria, P. .
NUCLEAR FUSION, 2009, 49 (04)
[8]   Control of negative ion beam uniformity by using multipower supplies for arc discharge [J].
Ikeda, K ;
Takeiri, Y ;
Kaneko, O ;
Nagaoka, K ;
Oka, Y ;
Osakabe, M ;
Tsumori, K ;
Sato, M ;
Asano, E ;
Kawamoto, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05) :1744-1746
[9]  
Kraus W., 2 INT S NEG IONS BEA
[10]   Gas flow and related beam losses in the ITER neutral beam injector [J].
Krylov, A. ;
Hemsworth, R. S. .
FUSION ENGINEERING AND DESIGN, 2006, 81 (19) :2239-2248