Spatially resolved NMR thermometry of an operating fixed-bed catalytic reactor

被引:39
作者
Koptyug, Igor V. [1 ]
Khomichev, Alexey V. [1 ]
Lysova, Anna A. [1 ]
Sagdeev, Renad Z. [1 ]
机构
[1] SB RAS, Int Tomog Ctr, Novosibirsk, Russia
关键词
D O I
10.1021/ja802075m
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An MRI-based approach for the thermometry of an operating packed-bed catalytic reactor was implemented. It was employed for the spatially resolved NMR thermometry of the bed of Pd/y-Al(2)O(3) catalyst beads in the course of propylene hydrogenation reaction. This was achieved by detecting the spatially resolved axial 1D profiles of the (27)Al NMR signal intensity of Al(2)O(3) in the course of the reaction. The experimental results demonstrate a clear correlation between the (27)Al NMR signal intensity and the catalyst temperature measured with a thermocouple (25-250 degrees C), and reveal the existence of pronounced temperature gradients along the catalyst bed.
引用
收藏
页码:10452 / +
页数:3
相关论文
共 50 条
[41]   THE BEHAVIOR OF A FIXED-BED REACTOR - REPLY [J].
VARMA, A ;
MORBIDELLI, M .
CHEMICAL ENGINEERING SCIENCE, 1991, 46 (12) :3331-3332
[42]   LIGNITE DEVOLATILIZATION IN A FIXED-BED REACTOR [J].
GOKHALE, AJ ;
MAHALINGAM, R .
ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR) :19-INDE
[43]   Autothermal fixed-bed reactor concepts [J].
Kolios, G ;
Frauhammer, J ;
Eigenberger, G .
CHEMICAL ENGINEERING SCIENCE, 2000, 55 (24) :5945-5967
[44]   BIODEGRADATION OF XENOBIOTICS IN A FIXED-BED REACTOR [J].
SEIGNEZ, C ;
MOTTIER, V ;
PULGARIN, C ;
ADLER, N ;
PERINGER, P .
ENVIRONMENTAL PROGRESS, 1993, 12 (04) :306-311
[45]   COMMENTS ON THE BEHAVIOR OF A FIXED-BED REACTOR [J].
BOS, ANR ;
WESTERTERP, KR .
CHEMICAL ENGINEERING SCIENCE, 1991, 46 (12) :3330-3331
[46]   Variability of operating safety limits with catalyst within a fixed-bed catalytic reactor for vapour-phase nitrobenzene hydrogenation [J].
Maria, Gheorghe ;
Stefan, Dragos-Nicolae .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2010, 23 (01) :112-126
[47]   THE PSEUDOADIABATIC REGIME FOR CATALYTIC FIXED-BED REACTORS - THE LIMITING OPERATING-CONDITIONS [J].
RAVELLA, A ;
DELASA, H .
CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1987, 34 (01) :47-53
[48]   Bed lumped reaction kinetics of a fixed-bed reactor [J].
Cheng, ZM ;
Yuan, WK .
PROGRESS IN NATURAL SCIENCE, 1997, 7 (01) :51-57
[49]   Comparison between a fixed-bed reactor and a chromatographic reactor [J].
Falk, T ;
Seidel-Morgenstern, A .
CHEMICAL ENGINEERING SCIENCE, 1999, 54 (10) :1479-1485
[50]   SENSITIVITY ANALYSIS CONCERNING THE DESIGN AND OPERATION OF A TUBULAR FIXED-BED CATALYTIC REACTOR [J].
DEAZEVEDO, SF ;
WARDLE, AP .
CHEMICAL ENGINEERING SCIENCE, 1989, 44 (10) :2311-2322