Biomechanical analysis of transverse acetabular fracture fixation in the elderly via the posterior versus the anterior approach with and without a total hip arthroplasty

被引:8
作者
Moktar, Joel [1 ]
Machin, Alan [2 ]
Bougherara, Habiba [2 ]
Schemitsch, Emil H. [1 ,3 ]
Zdero, Radovan [2 ,3 ,4 ]
机构
[1] Univ Toronto, Fac Med, Dept Surg, Toronto, ON, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[3] Western Univ, Div Orthopaed Surg, London, ON, Canada
[4] Western Univ, Dept Mech & Mat Engn, London, ON, Canada
关键词
Biomechanics; transverse acetabular fracture; fracture fixation; total hip arthroplasty; posterior approach; anterior approach; MODIFIED STOPPA APPROACH; INTERNAL-FIXATION; REDUCTION;
D O I
10.1177/0954411920935759
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study provides the first biomechanical comparison of the fixation constructs that can be created to treat transverse acetabular fractures when using the "gold-standard" posterior versus the anterior approach with and without a total hip arthroplasty in the elderly. Synthetic hemipelvises partially simulating osteoporosis (n = 24) were osteotomized to create a transverse acetabular fracture and then repaired using plates/screws, lag screws, and total hip arthroplasty acetabular components in one of four ways: posterior approach (n = 6), posterior approach plus a total hip arthroplasty acetabular component (n = 6), anterior approach (n = 6), and anterior approach plus a total hip arthroplasty acetabular component (n = 6). All specimens were biomechanically tested. No differences existed between groups for stiffness (range, 324.6-387.3 N/mm, p = 0.629), clinical failure load at 5 mm of femoral head displacement (range, 1630.1-2203.9 N, p = 0.072), or interfragmentary gapping (range, 0.67-1.33 mm, p = 0.359). Adding a total hip arthroplasty acetabular component increased ultimate mechanical failure load for posterior (2904.4 vs. 3652.3 N, p = 0.005) and anterior (3204.9 vs. 4396.0 N, p = 0.000) approaches. Adding a total hip arthroplasty acetabular component also substantially reduced interfragmentary sliding for posterior (3.08 vs. 0.50 mm, p = 0.002) and anterior (2.17 vs. 0.29 mm, p = 0.024) approaches. Consequently, the anterior approach with a total hip arthroplasty may provide the best biomechanical stability for elderly patients, since this fixation group had the highest mechanical failure load and least interfragmentary sliding, while providing equivalent stiffness, clinical failure load, and gapping compared to other surgical options.
引用
收藏
页码:966 / 974
页数:9
相关论文
共 30 条
[1]   Modified Stoppa Approach for Acetabular Fractures With Anterior and Posterior Column Displacement: Quantification of Radiographic Reduction and Analysis of Interobserver Variability [J].
Andersen, Romney C. ;
O'Toole, Robert V. ;
Nascone, Jason W. ;
Sciadini, Marcus F. ;
Frisch, H. Michael ;
Turen, Clifford W. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (05) :271-278
[2]   The Modified Stoppa Approach for Acetabular Fracture [J].
Archdeacon, Michael T. ;
Kazemi, Namdar ;
Guy, Pierre ;
Sagi, Henry C. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (03) :170-175
[3]  
Aziz MSR, 2017, EXPERIMENTAL METHODS IN ORTHOPAEDIC BIOMECHANICS, P149, DOI 10.1016/B978-0-12-803802-4.00010-X
[4]   Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA [J].
Aziz, Mina S. R. ;
Dessouki, Omar ;
Samiezadeh, Saeid ;
Bougherara, Habiba ;
Schemitsch, Emil H. ;
Zdero, Radovan .
MEDICAL ENGINEERING & PHYSICS, 2017, 46 :71-78
[5]  
Aziz MSR, 2014, THESIS
[6]  
Caviglia H, 2018, EFORT OPEN REV, V1700, P31
[7]  
Chang JK, 2001, CLIN ORTHOP RELAT R, P433
[8]   Fractures of the acetabulum in patients aged 60 years and older AN EPIDEMIOLOGICAL AND RADIOLOGICAL STUDY [J].
Ferguson, T. A. ;
Patel, R. ;
Bhandari, M. ;
Matta, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (02) :250-257
[9]  
Fogiel M, 2004, HDB MECH ENG
[10]   Biomechanical Analysis of Acetabular Revision Constructs Is Pelvic Discontinuity Best Treated With Bicolumnar or Traditional Unicolumnar Fixation? [J].
Gililland, Jeremy M. ;
Anderson, Lucas A. ;
Henninger, Heath B. ;
Kubiak, Erik N. ;
Peters, Christopher L. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (01) :178-186