Concordance of coronary artery calcium estimates between MDCT and electron beam tomography

被引:46
作者
Daniell, AL
Wong, ND
Friedman, JD
Ben-Yosef, N
Miranda-Peats, R
Hayes, SW
Kang, XP
Sciammarella, MG
de Yang, L
Germano, G
Berman, DS
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Div Nucl Med, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Div Cardiol, Los Angeles, CA 90048 USA
[3] Univ Calif Irvine, Heart Dis Prevent Program, Div Cardiol, Irvine, CA USA
关键词
D O I
10.2214/AJR.04.0333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare MDCT with electron beam tomography (EBT) for the quantification of coronary artery calcification (CAC). MATERIALS AND METHODS. Sixty-eight patients underwent both MDCT and EBT within 2 months for the quantification of CAC. The images were scored in a blinded fashion and independently by two observers with a minimum of 7 days between the interpretations of images obtained from one scanner type to the other. RESULTS. Presence versus absence of CAC was discordant by EBT versus MDCT in 6% (n = 4) of the cases by observer 1, with one of these cases also discordant by observer 2. All cases except one (aortic calcium misidentified as CAC) were among those with a mean Agatston score of less than 5 present on EBT but absent on MDCT. EBT and MDCT scores correlated well (r = 0.98-0.99). The relative median variability between EBT and MDCT for the Agatston score was 24% for observer 1 and 27% for observer 2 and was 18% and 14%, respectively, for volume score (average for both observers: 27% for Agatston score and 16% for volume score). Scores were higher for EBT than MDCT in approximately half of the cases, with little systematic difference between the two (median EBT-MDCT difference: Agatston score, -0.55; volume score, 3.4 mm(3)). The absolute median difference averaged for the two observers was 28.75 for the Agatston score and 15.4 mm(3) for the volume score. CONCLUSION. Differences in CAC measurements using EBT and MDCT are similar to interscan differences in CAC measurements previously reported for EBT or for other MDCT scanners individually.
引用
收藏
页码:1542 / 1545
页数:4
相关论文
共 15 条
  • [1] Recommendations for standardization of EBT and MSCT scanning
    Achenbach, S
    Daniel, WG
    Moshage, W
    [J]. HERZ, 2001, 26 (04) : 273 - +
  • [2] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [3] Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification
    Becker, CR
    Jakobs, TF
    Aydemir, S
    Becker, A
    Knez, A
    Schoepf, UJ
    Bruening, R
    Haberl, R
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) : 543 - 547
  • [4] Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP
    Becker, CR
    Kleffel, T
    Crispin, A
    Knez, A
    Young, J
    Schoepf, UJ
    Haberl, R
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) : 1295 - 1298
  • [5] Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    Callister, TQ
    Cooil, B
    Raya, SP
    Lippolis, NJ
    Russo, DJ
    Raggi, P
    [J]. RADIOLOGY, 1998, 208 (03) : 807 - 814
  • [6] Evaluation of subsecond gated helical CT for quantification of coronary artery calcium and comparison with electron beam CT
    Carr, JJ
    Crouse, JR
    Goff, DC
    D'Agostino, RB
    Peterson, NP
    Burke, GL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) : 915 - 921
  • [7] Spiral versus electron-beam CT for coronary artery calcium scoring
    Goldin, JG
    Yoon, HC
    Greaser, LE
    Heinze, SB
    McNitt-Gray, MM
    Brown, MS
    Sayre, JW
    Emerick, AM
    Aberle, DR
    [J]. RADIOLOGY, 2001, 221 (01) : 213 - 221
  • [8] Coronary artery calcium quantification at multi-detector row CT: Influence of heart rate and measurement methods on interaequisition variability - Initial experience
    Hong, C
    Bae, KT
    Pilgram, TK
    Zhu, F
    [J]. RADIOLOGY, 2003, 228 (01) : 95 - 100
  • [9] Comparison of electron-beam and ungated helical CT in detecting coronary arterial calcification by using a working heart phantom and artificial coronary arteries
    Hopper, KD
    Strollo, DC
    Mauger, DT
    [J]. RADIOLOGY, 2002, 222 (02) : 474 - 482
  • [10] Coronary artery calcium scoring using 16-MDCT and a retrospective ECG-gating reconstruction algorithm
    Horiguchi, J
    Yamamoto, H
    Akiyama, Y
    Marukawa, K
    Hirai, N
    Ito, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (01) : 103 - 108