Optimizing glenoid component position using three-dimensional computed tomography reconstruction

被引:53
作者
Hoenecke, Heinz R., Jr. [1 ]
Hermida, Juan C. [2 ]
Dembitsky, Nicholas [2 ]
Patil, Shantanu [2 ]
D'Lima, Darryl D. [2 ]
机构
[1] Scripps Clin, Div Orthopaed Surg, La Jolla, CA 92037 USA
[2] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
D O I
10.1016/j.jse.2007.11.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Glenoid implant design and alignment are critical to the success of shoulder arthroplasty. Computer-aided design models of 3 glenoid implant designs (keel, standard pegs, and modified pegs) were virtually implanted into 3-dimensional computed tomography-reconstructed models of 40 normal scapulae. The incidence of perforation on 3-dimensional computed tomography preoperative templating varied from 8% to 18% for the 3 models. Malalignment of the implants in retroversion was better tolerated than anteversion and varied with implant design. Tolerance for medialization of the implant to correct for glenoid wear was limited (range, 0 degrees-18 degrees) and varied with implant design. The modified peg design had the lowest incidence of perforation, the greatest tolerance for malalignment, and the ability to correct for glenoid wear effects. These results emphasize the need for accurate preoperative templating and for developing alignment guides or surgical navigation tools for shoulder arthroplasty and may be used to improve implant fixation designs.
引用
收藏
页码:637 / 641
页数:5
相关论文
共 13 条
[1]   Complications of total shoulder arthroplasty [J].
Bohsali, Kamal I. ;
Wirth, Michael A. ;
Rockwood, Charles A., Jr. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2279-2292
[2]   Fit of current glenoid component designs: An anatomic cadaver study [J].
Checroun, AJ ;
Hawkins, C ;
Kummer, FJ ;
Zuckerman, JD .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (06) :614-617
[3]   Shoulder arthroplasty versus hip and knee arthroplasties - A comparison of outcomes [J].
Farmer, Kevin W. ;
Hammond, Jason W. ;
Queale, William S. ;
Keyurapan, Ekavit ;
McFarland, Edward G. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (455) :183-189
[4]   THE USE OF COMPUTERIZED-TOMOGRAPHY IN THE MEASUREMENT OF GLENOID VERSION [J].
FRIEDMAN, RJ ;
HAWTHORNE, KB ;
GENEZ, BM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1032-1037
[5]   Developments in shoulder arthroplasty [J].
Gregory, T. ;
Hansen, U. ;
Emery, R. J. ;
Augereau, B. ;
Amis, A. A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H1) :87-96
[6]   The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty [J].
Hopkins, AR ;
Hansen, UN ;
Amis, AA ;
Emery, R .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (06) :668-675
[7]   Incidence of early radiolucent glenoid lines in patients having total shoulder replacements [J].
Klepps, S ;
Chiang, AS ;
Miller, S ;
Jiang, CY ;
Hazrati, Y ;
Flatow, EL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (435) :118-125
[8]   Use of three-dimensional computed tomography for the analysis of the glenoid anatomy [J].
Kwon, YW ;
Powell, KA ;
Yum, JK ;
Brems, JJ ;
Iannotti, JP .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :85-90
[9]  
McGraw KO, 1996, PSYCHOL METHODS, V1, P30, DOI 10.1037/1082-989X.1.4.390
[10]   Effects of glenoid component version on humeral head displacement and joint reaction forces: An experimental study [J].
Nyffeler, Richard W. ;
Sheikh, Ralph ;
Atkinson, Todd S. ;
Jacob, Hilaire A. C. ;
Favre, Philippe ;
Gerber, Christian .