Phytoforensics: Trees as bioindicators of potential indoor exposure via vapor intrusion

被引:5
|
作者
Wilson, Jordan L. [1 ,2 ]
Samaranayake, V. A. [3 ]
Limmer, Matt A. [4 ]
Burken, Joel G. [2 ]
机构
[1] US Geol Survey, Missouri Water Sci Ctr, Rolla, MO USA
[2] Missouri Univ Sci & Technol, Dept Civil Environm & Architectural Engn, Rolla, MO 65409 USA
[3] Missouri Univ Sci & Technol, Dept Math & Stat, Rolla, MO USA
[4] Univ Delaware, Dept Plant & Soil Sci, Newark, DE 19716 USA
来源
PLOS ONE | 2018年 / 13卷 / 02期
基金
美国国家科学基金会;
关键词
SOIL; PLUME; CONTAMINATION; VARIABILITY; GROUNDWATER; SORPTION; WOOD; PCE;
D O I
10.1371/journal.pone.0193247
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Human exposure to volatile organic compounds (VOCs) via vapor intrusion (VI) is an emerging public health concern with notable detrimental impacts on public health. Phytoforensics, plant sampling to semi-quantitatively delineate subsurface contamination, provides a potential non-invasive screening approach to detect VI potential, and plant sampling is effective and also time-and cost-efficient. Existing VI assessment methods are time-and resource-intensive, invasive, and require access into residential and commercial buildings to drill holes through basement slabs to install sampling ports or require substantial equipment to install groundwater or soil vapor sampling outside the home. Tree-core samples collected in 2 days at the PCE Southeast Contamination Site in York, Nebraska were analyzed for tetrachloroethene (PCE) and results demonstrated positive correlations with groundwater, soil, soil-gas, sub-slab, and indoor-air samples collected over a 2-year period. Because tree-core samples were not collocated with other samples, interpolated surfaces of PCE concentrations were estimated so that comparisons could be made between pairs of data. Results indicate moderate to high correlation with average indoor-air and sub-slab PCE concentrations over long periods of time (months to years) to an interpolated tree-core PCE concentration surface, with Spearman's correlation coefficients (rho) ranging from 0.31 to 0.53 that are comparable to the pairwise correlation between sub-slab and indoor-air PCE concentrations (rho = 0.55, n = 89). Strong correlations between soil-gas, sub-slab, and indoor-air PCE concentrations and an interpolated tree-core PCE concentration surface indicate that trees are valid indicators of potential VI and human exposure to subsurface environment pollutants. The rapid and non-invasive nature of tree sampling are notable advantages: even with less than 60 trees in the vicinity of the source area, roughly 12 hours of tree-core sampling with minimal equipment at the PCE Southeast Contamination Site was sufficient to delineate vapor intrusion potential in the study area and offered comparable delineation to traditional sub-slab sampling performed at 140 properties over a period of approximately 2 years.
引用
收藏
页数:17
相关论文
共 28 条
  • [1] Contaminant Gradients in Trees: Directional Tree Coring Reveals Boundaries of Soil and Soil-Gas Contamination with Potential Applications in Vapor Intrusion Assessment
    Wilson, Jordan L.
    Samaranayake, V. A.
    Limmer, Matthew A.
    Schumacher, John G.
    Burken, Joel G.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (24) : 14055 - 14064
  • [2] High-frequency fluctuations of indoor pressure: A potential driving force for vapor intrusion in urban areas
    Yao, Yijun
    Xiao, Yuting
    Luo, Jian
    Wang, Genfu
    Strom, Jonathan
    Suuberg, Eric
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 710 (710)
  • [3] Evaluating the vapor intrusion to indoor air exposure pathway public health consultations for the Chillum Perchlorethylene site, Chillum, Maryland
    Zhu, Jane
    Mutter, Jamie
    Kowalski, Peter
    Kaplan, Brian
    Moore, Susan
    Werner, Lora
    Markiewicz, Karl
    Proceedings of the 4th International Academic Conference on Environmental and Occupational Medicine, 2007, : 19 - 24
  • [4] Updating Exposure Models of Indoor Air Pollution Due to Vapor Intrusion: Bayesian Calibration of the Johnson-Ettinger Model
    Johnston, Jill E.
    Sun, Qiang
    Gibson, Jacqueline MacDonald
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (04) : 2130 - 2138
  • [5] Water Vapor Single-Gas Selectivity via Flexibility of Three Potential Materials for Autonomous Indoor Humidity Control
    Tsobnang, Patrice Kenfack
    Hasturk, Emrah
    Frohlich, Dominik
    Wenger, Emmanuel
    Durand, Pierrick
    Ngolui, John Lambi
    Lecomte, Claude
    Janiak, Christoph
    CRYSTAL GROWTH & DESIGN, 2019, 19 (05) : 2869 - 2880
  • [6] Evaluation of Passive Diffusive-Adsorptive Samplers for Use in Assessing Time-Varying Indoor Air Impacts Resulting from Vapor Intrusion
    Guo, Yuanming
    O'Neill, Harry
    Dahlen, Paul
    Johnson, Paul C.
    GROUND WATER MONITORING AND REMEDIATION, 2022, 42 (01) : 38 - 49
  • [7] Numerical Model Investigation for Potential Methane Explosion and Benzene Vapor Intrusion Associated with High-Ethanol Blend Releases
    Ma, Jie
    Luo, Hong
    DeVaull, George E.
    Rixey, William G.
    Alvarez, Pedro J. J.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (01) : 474 - 481
  • [8] Spatiotemporal variability of tetrachloroethylene in residential indoor air due to vapor intrusion: a longitudinal, community-based study
    Johnston, Jill E.
    Gibson, Jacqueline MacDonald
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2014, 24 (06) : 564 - 571
  • [9] Research Needs Regarding the Vapor Intrusion Potential of Volatile Per- and Polyfluoroalkyl Substances
    Kapuscinski, Richard B.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (09) : 4056 - 4059
  • [10] Potential exposure of children to environmental microorganisms in indoor healthcare and educational settings
    D'Arcy, N.
    Cloutman-Green, E.
    Lai, K. M.
    Margaritis, D.
    Klein, N.
    Spratt, D. A.
    INDOOR AND BUILT ENVIRONMENT, 2014, 23 (03) : 467 - 473