PHILOS Synthesis for Proximal Humerus Fractures Has High Complications and Reintervention Rates: A Systematic Review and Meta-Analysis

被引:32
作者
Oldrini, Lorenzo Massimo [1 ]
Feltri, Pietro [1 ]
Albanese, Jacopo [1 ]
Marbach, Francesco [1 ]
Filardo, Giuseppe [1 ,2 ]
Candrian, Christian [1 ,2 ]
机构
[1] EOC, Dept Surg, Serv Orthopaed & Traumatol, CH-6900 Lugano, Switzerland
[2] Univ Svizzera Italiana, Fac Biomed Sci, Via Buffi 13, CH-6900 Lugano, Switzerland
来源
LIFE-BASEL | 2022年 / 12卷 / 02期
关键词
PHILOS; locking plate; proximal humeral fracture; PHF; osteosynthesis; INVASIVE PLATE OSTEOSYNTHESIS; LOCKING COMPRESSION PLATE; INTERNAL-FIXATION; ELDERLY-PATIENTS; RISK-FACTORS; DISPLACED FRACTURES; OPEN REDUCTION; MULTICENTER; SHOULDER; OUTCOMES;
D O I
10.3390/life12020311
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: The aim of this study was to quantify the rate of complications and reinterventions in patients treated with PHILOS plate for proximal humerus fractures (PHFs) synthesis. Methods: A comprehensive literature search was performed on the PubMed, Web of Science, Embase, and Cochrane databases up to 7 October 2021. Studies describing medium and long-term complications in PHF synthesis using the PHILOS plate were included. A systematic review and meta-analysis were performed on complications and causes of reinterventions. Assessment of risk of bias and quality of evidence was performed with the Downs and Black's "Checklist for Measuring Quality". Results: Seventy-six studies including 4200 patients met the inclusion criteria. The complication rate was 23.8%, and the main cause was screw cut-out (4.1%), followed by avascular necrosis (AVN) (3.1%) and subacromial impingement (1.5%). In patients over 55 years, the complication rate was 29.5%. In the deltopectoral (DP) approach the complication rate was 23.8%, and in the delto-split (DS) it was 17.5%, but no difference between the two approaches was seen when considering the type of fracture. The overall reintervention rate was 10.5% in the overall population and 19.0% in older patients. Conclusions: Proximal humerus synthesis with a PHILOS plate has high complications and reintervention rates. The most frequent complication was screw cut-out, followed by humeral head AVN and subacromial impingement. These results need to be further investigated to better understand both the type of patient and fracture that is more at risk of complications and reintervention and to compare pros and cons of the PHILOS plate with respect to the other solutions to manage PHFs.
引用
收藏
页数:18
相关论文
共 69 条
[1]   A prospective analysis of the functional and radiological outcomes of minimally invasive plating in proximal humerus fractures [J].
Acklin, Yves P. ;
Stoffel, Karl ;
Sommer, Christoph .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04) :456-460
[2]   Minimal Invasive PHILOS®-Plate Osteosynthesis in Proximal Humeral Fractures [J].
Acklin, Yves P. ;
Jenni, Raphael ;
Walliser, Martin ;
Sommer, Christoph .
EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2009, 35 (01) :35-39
[3]  
[Anonymous], 2009, J ORTHOP TRAUMA, V23, P113, DOI 10.1097/BOT.0b013e31819344bf
[4]   Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate [J].
Barlow, Jonathan D. ;
Logli, Anthony L. ;
Steinmann, Scott P. ;
Sems, Stephen A. ;
Cross, William W. ;
Yuan, Brandon J. ;
Torchia, Michael E. ;
Sanchez-Sotelo, Joaquin .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (08) :1689-1694
[5]   The epidemiology of peripheral fractures [J].
Baron, JA ;
Barrett, JA ;
Karagas, MR .
BONE, 1996, 18 (03) :S209-S213
[6]   Plate fixation of the proximal humerus: an international multicentre comparative study of postoperative complications [J].
Beeres, Frank J. P. ;
Hallensleben, N. D. L. ;
Rhemrev, S. J. ;
Goslings, J. C. ;
Oehme, F. ;
Meylaerts, S. A. G. ;
Babst, R. ;
Schep, N. W. L. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) :1685-1692
[7]   Internal fixation of proximal humeral fractures with a locking compression plate -: A retrospective evaluation of 72 patients followed for a minimum of 1 year [J].
Björkenheim, JM ;
Pajarinen, J ;
Savolainen, V .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :741-745
[8]   Risk factors for humeral head necrosis and non-union after plating in proximal humeral fractures [J].
Boesmueller, Sandra ;
Wech, Margit ;
Gregori, Markus ;
Domaszewski, Florian ;
Bukaty, Adam ;
Fialka, Christian ;
Albrecht, Christian .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (02) :350-355
[9]   Hemiarthroplasty for Humeral Four-part Fractures for Patients 65 Years and Older A Randomized Controlled Trial [J].
Boons, Harm W. ;
Goosen, Jon H. ;
van Grinsven, Susan ;
van Susante, Job L. ;
van Loon, Corne J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (12) :3483-3491
[10]   Mid-term results of minimally invasive deltoid-split versus standard open deltopectoral approach for PHILOS™ (proximal humeral internal locking system) osteosynthesis in proximal humeral fractures [J].
Borer, Joelle ;
Schwarz, Jochen ;
Potthast, Silke ;
Jakob, Marcel ;
Lenzlinger, Philipp ;
Zingg, Urs ;
Babians, Arby .
EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (04) :825-834