Chlorpromazine quantification in human plasma by UPLC-electrospray ionization tandem mass spectrometry. Application to a comparative pharmacokinetic study

被引:18
作者
Borges, Ney Carter [1 ,2 ]
Rezende, Vinicius Marcondes [3 ]
Santana, Jose Marcos [3 ]
Moreira, Ricardo Pereira [1 ]
Moreira, Roberto Fernandes [2 ]
Moreno, Patricia [1 ,4 ]
Borges, Diego Carter [1 ,5 ]
Donato, Jose Luiz [1 ,6 ]
Moreno, Ronilson Agnaldo [1 ,7 ]
机构
[1] Synchrophar Assessoria & Desenvolvimento Projetos, Campinas, SP, Brazil
[2] Univ Estadual Campinas, Dept Internal Med, Fac Med Sci, Campinas, SP, Brazil
[3] Synchrophar Analit, Paulinia, SP, Brazil
[4] Sao Francisco Univ USF, Fac Med, Braganca Paulista, SP, Brazil
[5] Jundiai Fac Med, Jundiai, SP, Brazil
[6] ATCGen Biotechnol, Campinas, SP, Brazil
[7] State Univ Campinas UN1CAMP, Dept Pharmacol, Fac Med Sci, Campinas, SP, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 31期
关键词
Chlorpromazine; UPLC-MS/MS; Bioavailability; Pharmacokinetics; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN SERUM; DRUG; ASSAY; RADIOIMMUNOASSAY; PHENOTHIAZINES; QUANTITATION;
D O I
10.1016/j.jchromb.2011.10.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present study a method to quantify chlorpromazine in human plasma using cyclobenzaprine as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by a liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) and analyzed by an ultra performance liquid chromatography (UPLC) coupled to an electrospray tandem triple quadrupole mass spectrometer in positive mode (UPLC-ES+-MS/MS). Chromatography was performed isocratically on an Aquity UPLC BEH C18 1.7 mu m (50 mm x 2.1 mm i.d.) operating at 40 degrees C. The mobile phase was a mixture of 65% water + 1% formic acid and 35% of acetonitrile at a flow-rate of 0.5 mL/min. The lowest concentration quantified was 0.5 ng/mL and a linear calibration curve over the range 0.5-200 ng/mL was obtained, showing intra-assay precisions from 2.4 to 5.8%, and inter-assay precisions from 3.6 to 9.9%. The intra-assay accuracies ranged from 96.9 to 102.5%, while the inter-assay accuracies ranged from 94.1 to 100.3%. This analytical method was applied in a relative bioavailability study in order to compare a test chlorpromazine 100 mg simple dose formulation versus a reference in 57 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a fourteen days washout period. Plasma samples were obtained over a 144-h interval. Since the 90% CI for both C-max, AUC(last), and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA, it was concluded that chlorpromazine 100 mg/dose was bioequivalent to the reference formulation, according to both the rate and extent of absorption. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3728 / 3734
页数:7
相关论文
共 29 条
[1]   Dispersive Liquid-liquid Microextraction Combined with High-performance Liquid Chromatography for the Determination of Clozapine and Chlorpromazine in Urine [J].
Chen, Jing ;
Xiong, Chaomei ;
Ruan, Jinlan ;
Su, Zou .
JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2011, 31 (02) :277-284
[2]   SUBNANOGRAM QUANTITATION OF CHLORPROMAZINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
COOPER, JK ;
MCKAY, G ;
MIDHA, KK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (11) :1259-1262
[3]   GAS-CHROMATOGRAPHIC DETERMINATION OF CHLORPROETHAZINE IN PLASMA [J].
GIRRE, C ;
KOCH, H ;
CROUZETTE, J ;
PALOMBO, S ;
FOURNIER, PE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :363-367
[4]   Analysis of phenothiazine and its derivatives using LC/electrochemistry/MS and LC/electrochemistry/fluorescence [J].
Hayen, H ;
Karst, U .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4833-4840
[5]   Past and Present Progress in the Pharmacologic Treatment of Schizophrenia [J].
Kane, John M. ;
Correll, Christoph U. .
JOURNAL OF CLINICAL PSYCHIATRY, 2010, 71 (09) :1115-1124
[6]   DEVELOPMENT OF RADIOIMMUNOASSAY FOR CHLORPROMAZINE [J].
KAWASHIMA, K ;
DIXON, R ;
SPECTOR, S .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1975, 32 (02) :195-202
[7]  
Kerns EH, 2006, CURR DRUG METAB, V7, P457
[8]   Quantitative determination of forty-eight antidepressants and antipsychotics in human serum by HPLC tandem mass spectrometry:: A multi-level, single-sample approach [J].
Kirchherr, H. ;
Kuehn-Velten, W. N. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 843 (01) :100-113
[9]  
Long J., 1992, The Essential Guide to Prescription Drugs
[10]  
Marzo A, 2007, ARZNEIMITTELFORSCH, V57, P122