Frameless laser-guided stereotaxis: A system for CT-monitored neurosurgical interventions

被引:3
作者
Hussman, KL
Chaloupka, JC
Berger, SB
Chon, KS
Broderick, M
机构
[1] Yale New Haven Hosp, Dept Diagnost Radiol, New Haven, CT 06504 USA
[2] Yale New Haven Hosp, Dept Neurosurg, New Haven, CT 06504 USA
关键词
brain; biopsy; frameless; laser; stereotaxis; CT scanning;
D O I
10.1159/000029649
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objective: Since a simple, rapid and accurate stereotactic system allowing CT monitoring would offer the neurosurgeon several advantages, the feasibility and application accuracy of frameless laser-guided freehand point stereotaxis for neurosurgical interventions was studied. Methods: A Cartesian coordinate grid mounted upon the far wall of a CT scan room defined a plane. The scanner isocenter defined the origin of a three-dimensional coordinate system, Phantom entry point and target point coordinates were determined by the positional CT cursor. These coordinates were entered into a computer which determined the coordinates of the grid intersection point with a line passing through the entry and target points. A tripod-mounted laser assembly comprising two encased lasers oriented retrograde and antegrade along opposite vectors, was positioned near the grid. The retrograde laser was positioned to illuminate the marked grid intersection point while the antegrade laser simultaneously illuminated the entry point; the beams were thereby aligned along the line of trajectory. The tip of a probe was placed on the entry point; the hub was then moved into the path of the antegrade laser, thereby aligning the probe with the line of trajectory. The probe was then inserted to the target at a trigonometrically calculated distance, Results: Ten consecutive phantom tests averaged 17.5 min, Phantom test application accuracy averaged +/-2 mm at an average insertion distance of 7.1 cm. Conclusion: Phantom tests indicate that simple, rapid and accurate CT-monitored frameless laser-guided freehand point stereotaxis is feasible. Clinical investigation is warranted.
引用
收藏
页码:62 / 75
页数:14
相关论文
共 11 条
  • [1] BARNETT GH, 1993, INTERACTIVE IMAGE GU, P113
  • [2] DRAKE JM, 1993, INTERACTIVE IMAGE GU, P121
  • [3] A LIGHT-GUIDANCE SYSTEM TO BE USED FOR CT-GUIDED BIOPSY
    FREDERICK, PR
    BROWN, TH
    MILLER, MH
    BAHR, AL
    TAYLOR, KH
    [J]. RADIOLOGY, 1985, 154 (02) : 535 - 536
  • [4] A COMPACT LASER-BEAM GUIDANCE-SYSTEM FOR INTERVENTIONAL CT
    GANGI, A
    KASTLER, B
    ARHAN, JM
    KLINKERT, A
    GRAMPP, JM
    DIETEMANN, JL
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 326 - 328
  • [5] THE APPLICATION ACCURACY OF STEREOTAXIC FRAMES
    MACIUNAS, RJ
    GALLOWAY, RL
    LATIMER, JW
    [J]. NEUROSURGERY, 1994, 35 (04) : 682 - 694
  • [6] LASER GUIDANCE-SYSTEM FOR CT-GUIDED PROCEDURES
    MIAUX, Y
    GUERMAZI, A
    GOSSOT, D
    BOURRIER, P
    ANGOULVANT, D
    KHAIROUNE, A
    TURKI, C
    BOUCHE, E
    [J]. RADIOLOGY, 1995, 194 (01) : 282 - 284
  • [7] LASER PROJECTION SYSTEM FOR RADIOTHERAPY AND CT-GUIDED BIOPSY
    NAGATA, Y
    NISHIDAI, T
    ABE, M
    HIRAOKA, M
    TAKAHASHI, M
    FUJIWARA, K
    OKAJIMA, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 1046 - 1048
  • [8] A NONINVASIVE THERMOPLASTIC HEAD IMMOBILIZATION SYSTEM - TECHNICAL NOTE
    PILIPUF, MN
    GOBLE, JC
    KASSELL, NF
    [J]. JOURNAL OF NEUROSURGERY, 1995, 82 (06) : 1082 - 1085
  • [9] A NEW HEAD HOLDER FOR REDUCING AXIAL MOVEMENT AND REPOSITIONING ERRORS DURING PHYSIOLOGICAL CT IMAGING
    SHRAWDER, S
    LAPIN, GD
    ALLEN, CV
    VICK, NA
    GROOTHUIS, DR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 329 - 336
  • [10] INTERACTIVE MR-GUIDED BIOPSY IN AN OPEN-CONFIGURATION MR-IMAGING SYSTEM
    SILVERMAN, SG
    COLLICK, BD
    FIGUEIRA, MR
    KHORASANI, R
    ADAMS, DF
    NEWMAN, RW
    TOPULOS, GP
    JOLESZ, FA
    [J]. RADIOLOGY, 1995, 197 (01) : 175 - 181