A new label dosimetry system based on pentacosa-diynoic acid monomer for low dose applications

被引:29
作者
Abdel-Fattah, A. A. [1 ]
Abdel-Rehim, F. [1 ]
Soliman, Y. S. [1 ]
机构
[1] Atom Energy Author, Natl Ctr Radiat Res & Technol, Nasr City, Cairo, Egypt
关键词
Label dosimetry; 10,12-Pentacosa-diynoic acid; Polyvinyl butyral; Reflectance measurements; Colorimeter; FILM; POLYMERIZATION;
D O I
10.1016/j.radphyschem.2011.08.011
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The dosimetric characteristics of gamma-radiation sensitive labels based on polyvinyl butyral (PVB) and a conjugated diacetylene monomer, 10,12-pentacosa-diynoic acid (PCDA) have been investigated using reflectance colorimeter. Two types of labels (colourless and yellow) based on PCDA monomer were prepared using an Automatic Film Applicator System. Upon gamma-ray exposure, the colourless label turns progressively blue, while the yellow colour label turns to green then to dark blue. The colour intensity of the labels is proportional to the radiation absorbed dose. The useful dose range was 15 Gy-2 kGy depending on PCDA monomer concentration. The expanded uncertainty of dose measurement of the colourless label was 6.06 (2 sigma). (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 26 条
[1]  
ABDELFATTAH AA, 2002, INT J POLYM MATER, V51, P851
[2]   Consideration of radiation-induced polymerization of diacetylene LB films for dosimetry [J].
Ali, NM ;
Tucker, CE ;
Smith, FA .
THIN SOLID FILMS, 1996, 289 (1-2) :267-271
[3]  
[Anonymous], 29 NPL CIRM
[4]  
[Anonymous], NIST TECH NOTE
[5]   Radiochromic film for medical radiation dosimetry [J].
Butson, MJ ;
Yu, PKN ;
Cheung, T ;
Metcalfe, P .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5) :61-120
[6]   Radiochromic film dosimetry in water phantoms [J].
Butson, MJ ;
Cheung, T ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01) :N27-N31
[7]   X-ray energy dependence of the dose response of SIRAD radiation dosimeters [J].
Cheung, Tsang ;
Butson, Martin J. ;
Yu, Peter K. N. .
APPLIED RADIATION AND ISOTOPES, 2007, 65 (07) :814-817
[8]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[9]   Validation of a label dosimeter for food irradiation applications by subjective and objective means [J].
Ehlermann, DAE .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (09) :1197-1201
[10]   Reactions and structural changes during thermal annealing in a semicrystalline, aromatic diacetylene-containing polyester [J].
Hu, XO ;
Li, XQ .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2002, 40 (20) :2354-2363