An aptamer based method for small molecules detection through monitoring salt-induced AuNPs aggregation and surface plasmon resonance (SPR) detection

被引:54
作者
Luo, Zewei [1 ]
Zhang, Ji [1 ,2 ]
Wang, Yimin [1 ]
Chen, Junman [1 ]
Li, Yu [1 ]
Duan, Yixiang [1 ]
机构
[1] Sichuan Univ, Coll Life Sci, Minist Educ, Key Lab Bioresource & Ecoenvironm,Res Ctr Analyt, Chengdu 610065, Peoples R China
[2] Sichuan Univ, Coll Chem, Chengdu 610065, Peoples R China
基金
中国国家自然科学基金;
关键词
U-shaped fiber optic probe; Surface plasmon resonance; Small molecule detection; Gold nanoparticles; UNMODIFIED GOLD NANOPARTICLES; BISPHENOL-A; COLORIMETRIC DETECTION; SIGNAL AMPLIFICATION; SENSOR; SENSITIVITY; BIOSENSOR; SILVER; FUNCTIONALIZATION; APTASENSOR;
D O I
10.1016/j.snb.2016.06.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid and sensitive method for small molecules detection based on surface plasmon resonance (SPR) is presented. In this work, aptamer and unmodified gold nanoparticles (AuNPs) were combined to construct a sensor for small molecules detection. The AuNPs/ssDNA complexes display excellent stability under high salt condition. However, in the presence of target molecules, the binding of aptamers/AuNPs would be broken, thus resulting in the aggregation of AuNPs due to the loss of protection by the aptamers. The aggregation of the unmodified AuNPs led to a change of refractive index of the solution. Thus, assay results can be obtained by a fiber optic surface plasmon resonance (FOSPR) probe. In order to improve the detection sensitivity, U-shaped fiber optic probe silver film coating was employed. This new method shows excellent analytical performance for bisphenol A (BPA) in the range of 0.0150 ng/mL (ppb) with a limit of detection (LOD) of 0.0037 ng/mL (ppb), which is about 30 times better than that of conventional enzyme-linked immunosorbent assay (ELISA). In addition, the proposed method exhibited excellent specificity, acceptable precision, and good accuracy. The proposed SPR assay was successfully applied to BPA determination in actual samples. Therefore, the present method was demonstrated to be promising for effective detection of small molecules. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:474 / 479
页数:6
相关论文
共 36 条
[1]   Fabrication and characterization of a surface plasmon resonance based fiber optic urea sensor for biomedical applications [J].
Bhatia, Priya ;
Gupta, Banshi D. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :434-438
[2]   Optical biosensors [J].
Borisov, Sergey M. ;
Wolfbeis, Otto S. .
CHEMICAL REVIEWS, 2008, 108 (02) :423-461
[3]   Toxicology: The big test for bisphenol A [J].
Borrell, Brendan .
NATURE, 2010, 464 (7292) :1122-1124
[4]   Wavelength-based localized surface plasmon resonance optical fiber biosensor [J].
Cao, Jie ;
Tu, Minh Hiue ;
Sun, Tong ;
Grattan, Kenneth T. V. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 :611-619
[5]   Review of plasmonic fiber optic biochemical sensors: improving the limit of detection [J].
Caucheteur, Christophe ;
Guo, Tuan ;
Albert, Jacques .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (14) :3883-3897
[6]   Enhancement of the second harmonic response by adsorbates on gold colloids: The effect of aggregation [J].
Galletto, P ;
Brevet, PF ;
Girault, HH ;
Antoine, R ;
Broyer, M .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (41) :8706-8710
[7]   Interparticle coupling effect on the surface plasmon resonance of gold nanoparticles: From theory to applications [J].
Ghosh, Sujit Kumar ;
Pal, Tarasankar .
CHEMICAL REVIEWS, 2007, 107 (11) :4797-4862
[8]   Surface plasmon resonance sensors for detection of chemical and biological species [J].
Homola, Jiri .
CHEMICAL REVIEWS, 2008, 108 (02) :462-493
[9]   Polydopamine-Functionalization of Graphene Oxide to Enable Dual Signal Amplification for Sensitive Surface Plasmon Resonance Imaging Detection of Biomarker [J].
Hu, Weihua ;
He, Guangli ;
Zhang, Huanhuan ;
Wu, Xiaoshuai ;
Li, Jialin ;
Zhao, Zhiliang ;
Qiao, Yan ;
Lu, Zhisong ;
Liu, Yang ;
Li, Chang Ming .
ANALYTICAL CHEMISTRY, 2014, 86 (09) :4488-4493
[10]   Hetero-core structured fiber optic surface plasmon resonance sensor with silver film [J].
Iga, M ;
Seki, A ;
Watanabe, K .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (03) :368-372