Personalized Automation of Treatment Planning for Linac-Based Stereotactic Body Radiotherapy of Spine Cancer

被引:3
作者
Cilla, Savino [1 ]
Cellini, Francesco [2 ]
Romano, Carmela [1 ]
Macchia, Gabriella [3 ]
Pezzulla, Donato [3 ]
Viola, Pietro [1 ]
Buwenge, Milly [4 ]
Indovina, Luca [5 ]
Valentini, Vincenzo [2 ,6 ]
Morganti, Alessio G. [4 ]
Deodato, Francesco [3 ,6 ]
机构
[1] Univ Cattolica Sacro Cuore, Med Phys Unit, Gemelli Molise Hosp, Campobasso, Italy
[2] Univ Cattolica Sacro Cuore, Radiat Oncol Dept, Fdn Policlin A Univ Gemelli, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Radiat Oncol Unit, Gemelli Molise Hosp, Campobasso, Italy
[4] Alma Mater Studiorum Univ Bologna, Ist Ricovero Cura Carattere Sci IRCCS, Azienda Osped Univ Bologna, Dipartaminto Med Specialist Diagnost & Sperimenta, Bologna, Italy
[5] Univ Cattolica Sacro Cuore, Med Phys Unit, Fdn Policlin Univ A Gemelli, Rome, Italy
[6] Univ Cattolica Sacro Cuore, Ist Radiol, Rome, Italy
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
关键词
automated planning; spine; stereotactic body radiation therapy (SBRT); volumetric modulated arc therapy (VMAT); pinnacle; VERTEBRAL COMPRESSION FRACTURE; RADIATION-THERAPY; METASTASES; QUALITY;
D O I
10.3389/fonc.2022.824532
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose/Objective(s)Stereotactic ablative body radiotherapy (SBRT) for vertebral metastases is a challenging treatment process. Planning automation has recently reported the potential to improve plan quality and increase planning efficiency. We performed a dosimetric evaluation of the new Personalized engine implemented in Pinnacle3 for full planning automation of SBRT spine treatments in terms of plan quality, treatment efficiency, and delivery accuracy. Materials/MethodsThe Pinnacle3 treatment planning system was used to reoptimize six patients with spinal metastases, employing two separate automated engines. These two automated engines, the existing Autoplanning and the new Personalized, are both template-based algorithms that employ a wishlist to construct planning goals and an iterative technique to replicate the planning procedure performed by skilled planners. The boost tumor volume (BTV) was defined as the macroscopically visible lesion on RM examination, and the planning target volume (PTV) corresponds with the entire vertebra. Dose was prescribed according to simultaneous integrated boost strategy with BTV and PTV irradiated simultaneously over 3 fractions with a dose of 30 and 21 Gy, respectively. Dose-volume histogram (DVH) metrics and conformance indices were used to compare clinically accepted manual plans (MP) with automated plans developed using both Autoplanning (AP) and Personalized engines (Pers). All plans were evaluated for planning efficiency and dose delivery accuracy. ResultsFor similar spinal cord sparing, automated plans reported a significant improvement of target coverage and dose conformity. On average, Pers plans increased near-minimal dose D98% by 10.4% and 8.9% and target coverage D95% by 8.0% and by 4.6% for BTV and PTV, respectively. Automated plans provided significantly superior dose conformity and dose contrast by 37%-47% and by 4.6%-5.7% compared with manual plans. Overall planning times were dramatically reduced to about 15 and 23 min for Pers and AP plans, respectively. The average beam-on times were found to be within 3 min for all plans. Despite the increased complexity, all plans passed the 2%/2 mm gamma-analysis for dose verification. ConclusionAutomated planning for spine SBRT through the new Pinnacle3 Personalized engine provided an overall increase of plan quality in terms of dose conformity and a major increase in efficiency. In this complex anatomical site, Personalized strongly reduce the tradeoff between optimal accurate dosimetry and planning time.
引用
收藏
页数:11
相关论文
共 39 条
[1]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[2]   Fully automated treatment planning of spinal metastases - A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation [J].
Buergy, Daniel ;
Sharfo, Abdul Wahab M. ;
Heijmen, Ben J. M. ;
Voet, Peter W. J. ;
Breedveld, Sebastiaan ;
Wenz, Frederik ;
Lohr, Frank ;
Stieler, Florian .
RADIATION ONCOLOGY, 2017, 12
[3]   Evaluation of thoracic spinal cord motion using dynamic MRI [J].
Cai, Jing ;
Sheng, Ke ;
Sheehan, Jason P. ;
Benedict, Stanley H. ;
Larner, James M. ;
Read, Paul W. .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (03) :279-282
[4]   Pain REduction with bone metastases STereotactic radiotherapy (PREST): A phase III randomized multicentric trial [J].
Cellini, Francesco ;
Manfrida, Stefania ;
Deodato, Francesco ;
Cilla, Savino ;
Maranzano, Ernesto ;
Pergolizzi, Stefano ;
Arcidiacono, Fabio ;
Di Franco, Rossella ;
Pastore, Francesco ;
Muto, Matteo ;
Borzillo, Valentina ;
Donati, Costanza Maria ;
Siepe, Giambattista ;
Parisi, Salvatore ;
Salatino, Antonia ;
D'Agostino, Antonino ;
Montesi, Giampaolo ;
Santacaterina, Anna ;
Fusco, Vincenzo ;
Santarelli, Mario ;
Gambacorta, Maria Antonietta ;
Corvo, Renzo ;
Morganti, Alessio Giuseppe ;
Masiello, Valeria ;
Muto, Paolo ;
Valentini, Vincenzo .
TRIALS, 2019, 20 (01)
[5]   Stereotactic Body Radiotherapy for Spinal Metastases: What are the Risks and How Do We Minimize Them? [J].
Chang, Joe H. ;
Shin, John H. ;
Yamada, Yoshiya J. ;
Mesfin, Addisu ;
Fehlings, Michael G. ;
Rhines, Laurence D. ;
Sahgal, Arjun .
SPINE, 2016, 41 (20) :S238-S245
[6]   Personalized Treatment Planning Automation in Prostate Cancer Radiation Oncology: A Comprehensive Dosimetric Study [J].
Cilla, Savino ;
Romano, Carmela ;
Morabito, Vittoria E. ;
Macchia, Gabriella ;
Buwenge, Milly ;
Dinapoli, Nicola ;
Indovina, Luca ;
Strigari, Lidia ;
Morganti, Alessio G. ;
Valentini, Vincenzo ;
Deodato, Francesco .
FRONTIERS IN ONCOLOGY, 2021, 11
[7]   Personalized automation of treatment planning in head-neck cancer: A step forward for quality in radiation therapy? [J].
Cilla, Savino ;
Deodato, Francesco ;
Romano, Carmela ;
Ianiro, Anna ;
Macchia, Gabriella ;
Re, Alessia ;
Buwenge, Milly ;
Boldrini, Luca ;
Indovina, Luca ;
Valentini, Vincenzo ;
Morganti, Alessio G. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 :7-16
[8]   Automated treatment planning as a dose escalation strategy for stereotactic radiation therapy in pancreatic cancer [J].
Cilla, Savino ;
Ianiro, Anna ;
Romano, Carmela ;
Deodato, Francesco ;
Macchia, Gabriella ;
Viola, Pietro ;
Buwenge, Milly ;
Cammelli, Silvia ;
Pierro, Antonio ;
Valentini, Vincenzo ;
Morganti, Alessio G. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11) :48-57
[9]   Template-based automation of treatment planning in advanced radiotherapy: a comprehensive dosimetric and clinical evaluation [J].
Cilla, Savino ;
Ianiro, Anna ;
Romano, Carmela ;
Deodato, Francesco ;
Macchia, Gabriella ;
Buwenge, Milly ;
Dinapoli, Nicola ;
Boldrini, Luca ;
Morganti, Alessio G. ;
Valentini, Vincenzo .
SCIENTIFIC REPORTS, 2020, 10 (01)
[10]   Partially ablative radiotherapy (PAR) for large mass tumors using simultaneous integrated boost: A dose-escalation feasibility study [J].
Cilla, Savino ;
Deodato, Francesco ;
Ianiro, Anna ;
Macchia, Gabriella ;
Picardi, Vincenzo ;
Buwenge, Milly ;
Cammelli, Silvia ;
Zamagni, Alice ;
Valentini, Vincenzo ;
Morganti, Alessio G. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06) :35-43