Long-term clinical safety and efficacy of NIROYAL vs. NIR intracoronary stent

被引:7
|
作者
Harding, SA [1 ]
McKenna, CJ [1 ]
Flapan, AD [1 ]
Boon, NA [1 ]
机构
[1] Univ Edinburgh, Royal Infirm, Dept Clin Cardiol, Edinburgh EH3 9YW, Midlothian, Scotland
关键词
stents; angioplasty; restenosis;
D O I
10.1002/ccd.1255
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Research in vitro and in animal models suggested that gold electroplating of stents can attenuate neointimal hyperplasia and reduce thrombogenicity. The objective of this study was to evaluate the safety and efficacy of the gold-coated NIROYAL stent in the treatment of stenosed coronary arteries and bypass grafts, We retrospectively studied 181 consecutive patients undergoing deployment of NIR (n = 87) or NIROYAL (n = 94) coronary stents in a single tertiary referral center from July 1997 to December 1998. Mean follow-up duration for the NIR and NIROYAL patient groups were 11.6 and 11.4 (range, 3-12) months, respectively. Stent thrombosis rates were 3/87 (3%) in the NIR and 0/94 (0%) in the NIROYAL group (P = 0.07). The need for target lesion revascularization (TLR) in the NIR patient group was 8/87 (9%) compared to 11/94 (12%) in the NIROYAL patient group (P = 0.6). The overall MACE rates for the NIR and NIROYAL patient groups were 24/87 (28%) and 22/94 (23%), respectively (P = 0.5). The present study, hence, implies equivalence between the stainless steel NIR and the gold-plated NIROYAL stent with no significant difference in immediate and long-term clinical performance profiles. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:141 / 145
页数:5
相关论文
共 50 条
  • [41] Long-term efficacy of intracoronary beta-radiation for treatment of diffuse in-stent restenosis: evidence for late restenosis
    Radke, PW
    Kaiser, A
    Kobella, S
    Haager, P
    Vom Dahl, J
    Janssens, U
    Hanrath, P
    Hoffmann, R
    EUROPEAN HEART JOURNAL, 2003, 24 : 143 - 143
  • [42] Stent vs. Stoma in malignant Colon Obstruction - Long Term Results
    Schrempf, M.
    Anthuber, M.
    CHIRURG, 2019, 90 : S47 - S47
  • [43] Long-term efficacy and safety of the Dumon stent for benign tracheal stenosis: a meta-analysis
    Chen, Di-Fei
    Chen, Yu
    Zhong, Chang-Hao
    Chen, Xiao-Bo
    Li, Shi-Yue
    JOURNAL OF THORACIC DISEASE, 2021, 13 (01) : 82 - U51
  • [44] The efficacy and safety of ureteral dilation and long-term type ureteral stent for patients with ureteral obstruction
    Kao, Ming-Hong
    Wang, Chung-Cheng
    UROLOGICAL SCIENCE, 2015, 26 (01) : 65 - 68
  • [45] Long-term efficacy and safety of aripiprazole vs. olanzapine in schizophrenia:: a 52-week, open-label extension study
    Ebrecht, M
    Modell, S
    Werner, C
    Spevakné-Göröcs, T
    Kungel, M
    PHARMACOPSYCHIATRY, 2005, 38 (05) : 238 - 238
  • [46] Hysteroscopic sterilization: Long-term safety and efficacy
    Kerin, JF
    OBSTETRICS AND GYNECOLOGY, 2005, 105 (04): : 56S - 56S
  • [47] The long-term efficacy and safety of 'Seroquel' (quetiapine)
    Arvanitis, LA
    Rak, IW
    SCHIZOPHRENIA RESEARCH, 1997, 24 (1-2) : 196 - 197
  • [48] The long-term efficacy and safety profile of barnidipine
    Smilde, JG
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2000, : 20 - 26
  • [49] LONG-TERM SAFETY AND EFFICACY PROFILE OF SIMVASTATIN
    BOCCUZZI, SJ
    BOCANEGRA, TS
    WALKER, JF
    SHAPIRO, DR
    KEEGAN, ME
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11): : 1127 - 1131
  • [50] Efficacy and safety of long-term omeprazole treatment
    Pashankar, DS
    GASTROENTEROLOGY, 2000, 119 (04) : 1177 - 1178