Comparison of tissue plasminogen activator-antibiotic locks with heparin-antibiotic locks in children with catheter-related bacteraemia

被引:19
作者
Onder, Ali Mirza [2 ]
Chandar, Jayanthi [1 ]
Simon, Nancy [3 ]
Diaz, Rosa [1 ]
Nwobi, Obioma [1 ]
Abitbol, Carolyn L. [1 ]
Zilleruelo, Gaston [1 ]
机构
[1] Univ Miami, Div Paediat Nephrol, Miller Sch Med, Dept Paediat, Miami, FL 33101 USA
[2] W Virginia Univ, Div Paediat Nephrol, Dept Paediat, Miami, FL USA
[3] Holtz Childrens Hosp, Div Paediat Pharm, Dept Pharm, Miami, FL USA
关键词
antibiotic lock solutions; biofilm; catheter-related bacteraemia; haemodialysis; tissue plasminogen activator;
D O I
10.1093/ndt/gfn023
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. An accepted pathogenesis of catheter-related bacteraemia (CRB) is the seeding of microorganisms from the intraluminal biofilm of central venous catheters. Antibiotic locks (ABL) are solutions containing high concentrations of antimicrobials with or without anticoagulants that aim to destroy the biofilm. Methods. In this study, two different ABL solutions, tissue plasminogen activator (TPA)-based and heparin-based ABL, used in conjunction with systemic antibiotics, were prospectively compared in the treatment of CRB. Results. A total of 42 children on chronic haemodialysis with 11 016 catheter-days were observed for signs and symptoms of CRB over a period of 10 months. Twenty-four CRBs were diagnosed in 18 children (2.2 CRB/1000 catheter-days) and were treated with the protocol. Symptoms of CRB resolved in 83% within 48 h of treatment. None of the infected catheters required early emergent exchange or removal for poorly controlled CRB. Six children had recurrence of CRB within 6 weeks, of which four required catheter exchange. There was no specific microorganism or type of CRB that predisposed to higher recurrence rates. The mean infection-free survival of the catheters following TPA-ABL treatment was shorter than that following heparin-ABL treatment, but was not statistically significant by the log-rank test (126.8 +/- 81.6 days versus 154.5 +/- 70.4 days). Conclusion. Both TPA-ABL and heparin-ABL used in conjunction with systemic antibiotics can effectively clear CRB without significant late recurrence at 6 weeks. Early use of ABL for management of CRB can potentially decrease the need for catheter removal, thus salvaging vascular access sites.
引用
收藏
页码:2604 / 2610
页数:7
相关论文
共 37 条
[11]   Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: A randomized controlled study [J].
Dogra, GK ;
Herson, H ;
Hutchison, B ;
Irish, AB ;
Heath, CH ;
Golledge, C ;
Luxton, G ;
Moody, H .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (08) :2133-2139
[12]   Hemodialysis catheter survival and complications in children and adolescents [J].
Goldstein, SL ;
Macierowski, CT ;
Jabs, K .
PEDIATRIC NEPHROLOGY, 1997, 11 (01) :74-77
[13]   Experience with autogenous arteriovenous access for hemodialysis in children and adolescents [J].
Gradman, WS ;
Lerner, G ;
Mentser, M ;
Rodriguez, H ;
Kamil, ES .
ANNALS OF VASCULAR SURGERY, 2005, 19 (05) :609-612
[14]  
HOEN B, 1995, NEPHROL DIAL TRANSPL, V10, P377
[15]  
Kovalik EC, 1996, J AM SOC NEPHROL, V7, P2264
[16]   Management of hemodialysis catheter-related bacteremia with an adjunctive antibiotic lock solution [J].
Krishnasami, Z ;
Carlton, D ;
Bimbo, L ;
Taylor, ME ;
Balkovetz, DF ;
Barker, J ;
Allon, M .
KIDNEY INTERNATIONAL, 2002, 61 (03) :1136-1142
[17]   HEMODIALYSIS ACCESS IN THE PEDIATRIC-PATIENT POPULATION [J].
LUMSDEN, AB ;
MACDONALD, J ;
ALLEN, RC ;
DODSON, TF .
AMERICAN JOURNAL OF SURGERY, 1994, 168 (02) :197-201
[18]  
Macrae Jennifer Marie, 2005, Hemodial Int, V9, P189, DOI 10.1111/j.1492-7535.2005.01131.x
[19]   Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis [J].
Marr, KA ;
Sexton, DJ ;
Conlon, PJ ;
Corey, GR ;
Schwab, SJ ;
Kirkland, KB .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :275-+
[20]   Locking of tunneled hemodialysis catheters with gentamicin and heparin [J].
McIntyre, CW ;
Hulme, LJ ;
Taal, M ;
Fluck, RJ .
KIDNEY INTERNATIONAL, 2004, 66 (02) :801-805