Thermal potential of a geothermal earth-to-air heat exchanger in six climatic conditions of Mexico

被引:12
作者
Rodriguez-Vazquez, M. [1 ]
Xaman, J. [1 ]
Chavez, Y. [1 ]
Hernandez-Perez, I. [2 ]
Sima, E. [1 ]
机构
[1] Tecnol Nacl Mexico CENIDET, Prol Ave Palmira S-N, Cuernavaca 62490, Morelos, Mexico
[2] UJAT, Div Acad Ingn & Arquitectura, Carretera Cunduacan Jalpa Mendez Km 1, Cunduacan 86690, Tabasco, Mexico
关键词
earth-to-air heat exchanger; thermal potential; passive cooling system; TRANSIENT SEMIANALYTICAL MODEL; EATHE SYSTEM; PERFORMANCE; ENERGY; DESIGN; HOT; TEMPERATURE; VALIDATION; SIMULATION; BUILDINGS;
D O I
10.1051/meca/2020016
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, the thermal and ventilation potential of a geothermal Earth-to-Air Heat exchanger (EAHE) is studied for six weather in Mexico. The cities for the study and their climate were Villahermosa (hot-humid), Merida (hot-sub humid), Monterrey (dry), Juarez City (very dry), Zacualtipan-Hidalgo (warm-humid) and Mexico City (warm-sub-humid). The thermal behavior of the EAHE was modeled numerically for the corresponding warmest and coldest days of the year for each city and three values of Reynolds number. The 24 hrs simulations were carried out with an in-house code using data every 10 minutes. To get the results, 5,184 computational runs were necessary. The results showed that the EAHE has poor ventilation potential for climates with high levels of humidity such as Villahermosa, while for cities with low levels of humidity such as Chihuahua, the ventilation potential increases significantly, the rest of the cities fall in between. As for its application in Mexico, the results show that the EAHE is highly recommended for dry climates such as at the north of the country and not recommended for humid climates such as at the south and south-east of the country.
引用
收藏
页数:20
相关论文
共 51 条
[1]   Optimization of operating parameters of earth air tunnel heat exchanger for space cooling: Taguchi method approach [J].
Agrawal, Kamal Kumar ;
Bhardwaj, Mayank ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Bansal, Vikas .
GEOTHERMAL ENERGY, 2018, 6 (01)
[2]   Experimental study to investigate the effect of water impregnation on thermal performance of earth air tunnel heat exchanger for summer cooling in hot and arid climate [J].
Agrawal, Kamal Kumar ;
Misra, Rohit ;
Yadav, Tejpal ;
Das Agrawal, Ghanshyam ;
Jamuwa, Doraj Kamal .
RENEWABLE ENERGY, 2018, 120 :255-265
[3]   Parametric study on thermal performance of horizontal earth pipe cooling system in summer [J].
Ahmed, S. F. ;
Amanullah, M. T. O. ;
Khan, M. M. K. ;
Rasul, M. G. ;
Hassan, N. M. S. .
ENERGY CONVERSION AND MANAGEMENT, 2016, 114 :324-337
[4]   Validation of CFD model for simulation of multi-pipe earth-to-air heat exchangers (EAHEs) flow performance [J].
Amanowicz, Lukasz ;
Wojtkowiak, Janusz .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 5 :44-49
[5]  
[Anonymous], 1980, HEMISPHERE SERIES CO
[6]  
Arcos Feria V.M., 2016, THESIS
[7]   Simple and accurate model for the ground heat exchanger of a passive house [J].
Badescu, Viorel .
RENEWABLE ENERGY, 2007, 32 (05) :845-855
[8]   Improvement of the summer cooling induced by an earth-to-air heat exchanger integrated in a residential building under hot and arid climate [J].
Benhammou, Mohammed ;
Draoui, Belkacem ;
Hamouda, Messaoud .
APPLIED ENERGY, 2017, 208 :428-445
[9]   Design of earth-air heat exchanger system [J].
Bisoniya, Trilok Singh .
GEOTHERMAL ENERGY, 2015, 3
[10]   Energy metrics of earth-air heat exchanger system for hot and dry climatic conditions of India [J].
Bisoniya, Trilok Singh ;
Kumar, Anil ;
Baredar, Prashant .
ENERGY AND BUILDINGS, 2015, 86 :214-221