This paper study systematic investigates the combined conductive and non-gray radiative heat transfer of open cell polyurethane (PU) foam in the pressure range between 760 and 0.02 Torr. Direct transmission measurements are also taken using Fourier transform infrared (FTIR) spectrometer. In doing so, experimental results are obtained for the spectral extinction coefficient from 2.5 to 25 mu m. In addition, the P-3 approximation method along with the box model is employed to calculate the non-gray radiative heat flux. The diffusion approximation method is also applied to calculated the radiative conductivity. Also tested herein are three samples with different cell sizes ranging from 330 to 147 mu m. According to those results, the spectral extinction coefficient increases with a decrease of cell size, leading to a decrease of thermal conductivity. Moreover, evacuating the gases in the foam cells can reduce the thermal conductivity of the PU foam by as much as 75%. Furthermore, radiative heat transfer accounts for about 4% of total heat transfer at 760 Torr and increases to 20% at 0.02 Torr.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 50 条
[21]   Convective heat transfer in tortuous heat radiator filled with open-cell copper foam [J].
Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230027, China .
Kung Cheng Je Wu Li Hsueh Pao, 2009, 11 (1936-1938)
[22]   Spectral radiative properties of open-cell foam insulation [J].
Baillis, D. ;
Raynaud, M. ;
Sacadura, J.F. .
Journal of thermophysics and heat transfer, 13 (03) :292-298
[23]   Spectral radiative properties of open-cell foam insulation [J].
Baillis, D ;
Raynaud, M ;
Sacadura, JF .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1999, 13 (03) :292-298
[24]   THERMAL-BEHAVIOR OF POLYURETHANE FOAM INSULATION [J].
FRASER, HW ;
JOFRIET, JC .
CANADIAN AGRICULTURAL ENGINEERING, 1993, 35 (01) :57-65
[25]   Polyurethane foam application for high voltage insulation [J].
Karady, GG ;
Argin, M ;
Rahmatian, F ;
Rose, AH .
2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, :526-529
[26]   Polyurethane Spray Foam for the Insulation of Buildings. [J].
Decker, Bauing H. .
Plastverarbeiter, 1982, 33 (01) :59-60
[27]   Porous Thermal Insulation Polyurethane Foam Materials [J].
Wang, Zhiguo ;
Wang, Chengzhu ;
Gao, Yuebin ;
Li, Zhao ;
Shang, Yu ;
Li, Haifu .
POLYMERS, 2023, 15 (18)
[28]   Dynamic crushing of auxetic open-cell polyurethane foam [J].
Scarpa, F ;
Yates, JR ;
Ciffo, LG ;
Patsias, S .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2002, 216 (12) :1153-1156
[29]   Effect of ligament hollowness on heat transfer characteristics of open-cell metal foam [J].
Moon, Chanhee ;
Kim, Daeyeon ;
Abadi, Gholamreza Bamorovat ;
Yoon, Sang Youl ;
Kim, Kyung Chun .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 :911-918
[30]   Heat-transfer analysis of high porosity open-cell metal foam [J].
Ghosh, Indranil .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2008, 130 (03)