Portable fluorescence sensor for on-line monitoring of lubricant oils

被引:5
|
作者
Liang, TK [1 ]
Friedrich, M [1 ]
Lala, D [1 ]
Ozanyan, KB [1 ]
机构
[1] Univ Manchester, Fac Engn & Phys Sci, Sch Elect & Elect Engn, Manchester M60 1QD, Lancs, England
来源
PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3 | 2004年
关键词
fluorescence; oil; optical fibre; PCA; neural networks;
D O I
10.1109/ICSENS.2004.1426086
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, we report on a portable, compact and inexpensive fluorescence sensor for monitoring the ageing of retail lubricant oils as a result of the operation in an internal combustion engine. The proposed sensor consists of a UV laser diode, an optical fibre probe for simultaneous excitation and collection of the fluorescence and a USB-powered palm-size spectrometer connected to a laptop. The sensor was applied on a set of oil samples, taken from production engines by a leading car manufacturing company, at various mileages. The subtle variations in the spectra, caused by the ageing process of the oil, are resolved using two methods: Principle Component Analysis (PCA) and Artificial Neural Networks (ANN). Their performance is compared with regard to utilization in a portable dedicated system for continuous in-situ monitoring. Because of the "fingerprinting" approach which avoids detailed interpretation, the sensor has a wide range of application areas.
引用
收藏
页码:8 / 11
页数:4
相关论文
共 50 条
  • [1] Tolerance analysis of a micro-optical detection system for on-line monitoring of lubricant oils
    Van Overmeire, S.
    Ottevaere, H.
    Mignani, A. G.
    Ciaccheri, L.
    Desmet, G.
    Thienpont, H.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (10)
  • [2] A Portable Fluorescence Sensor with Improved Performance for Aniline Monitoring
    Gao, Xinxiang
    Huang, Rongrong
    Fang, Wan
    Huang, Wei
    Yin, Zihao
    Liu, Yue
    Huang, Xinyu
    Ding, Liping
    Peng, Haonan
    Fang, Yu
    ADVANCED MATERIALS INTERFACES, 2022, 9 (34)
  • [3] On-line monitoring of the denitrification process by measurement of NADH fluorescence
    Lee, D
    Hoon Song, S
    Kim, JH
    Yoo, YJ
    BIOTECHNOLOGY LETTERS, 2002, 24 (11) : 949 - 952
  • [4] On-line monitoring of the denitrification process by measurement of NADH fluorescence
    Dohoon Lee
    Seung Hoon Song
    Ji Hyeon Kim
    Young Je Yoo
    Biotechnology Letters, 2002, 24 : 949 - 952
  • [5] The effect of the excitation light intensity during on-line monitoring of biodiesel by fluorescence spectroscopy
    Michels, Flavio S.
    Trindade, Magno A. G.
    Falcao, Evaristo A.
    Guimaraes, Rita C. A.
    Oliveira, Samuel L.
    Caires, Anderson R. L.
    FUEL, 2017, 193 : 395 - 400
  • [6] Red fluorescence sensor for noncontact on-line measurements in paper production
    Nilsson, CM
    Malmqvist, L
    Carlsson, J
    OPTICAL ENGINEERING, 2001, 40 (08) : 1674 - 1681
  • [7] 2-dimensional fluorescence spectroscopy for on-line bioprocess monitoring
    Lindemann, C
    Marose, S
    Nielsen, HO
    Scheper, T
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) : 273 - 277
  • [8] . On-line optimization of intensity and configuration of supplementary lighting using fluorescence sensor technology
    Schapendonk, A. H. C. M.
    Pot, C. S.
    Yin, X.
    Schreiber, U.
    PROCEEDINGS OF THE VTH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL LIGHTING IN HORTICULTURE, 2006, (711): : 423 - +
  • [9] Simple, sensitive and on-line fluorescence monitoring of photodegradation of phenol and 2-naphthol
    He, Yihua
    Lv, Yi
    Hu, Jing
    Qi, Linlin
    Hou, Xiandeng
    LUMINESCENCE, 2007, 22 (04) : 309 - 316
  • [10] On-line in situ monitoring of the soybean oil and ethanol transesterification reaction by fluorescence spectroscopy
    Izida, T.
    Bussler, L.
    Silva, J. R.
    Andrade, L. H. C.
    Simionatto, E.
    Simionatto, E. L.
    Scharf, D. R.
    Lima, S. M.
    FUEL, 2015, 145 : 109 - 115