Measurement of trabecular bone parameters with different bone thicknesses and voxel sizes in mice using micro-CT

被引:1
作者
Abu Bakar, Nurin Nadzlah [1 ]
Saidi, Basri [1 ]
Yamin, Lyana Shahirah Mohamad [1 ]
机构
[1] Univ Teknol MARA Puncak Alam, Fac Hlth Sci, Bandar Puncak Alam 42300, Selangor, Malaysia
来源
MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES | 2019年 / 15卷 / 01期
关键词
Micro-CT; trabecular bone parameter; bone thickness; voxel size; mice; TOMOGRAPHY;
D O I
10.11113/mjfas.v15n2019.1128
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Micro-CT is one of the best modalities in assessing bone morphology and microarchitecture in small animal models. Voxel size is directly related to the image resolution as it influences the bone morphology results. The purpose of this study was to assess the effects of double dagger different thicknesses of structures on the trabecular bone qualitative parameters. It was also to find out the most appropriate voxel size when scanning a certain or specific body part with different thicknesses. Five BALB-C breed mice carcasses were scanned using two different voxel sizes of 18 and 35 mu m. The scanning acquisition times were recorded to be compared and the trabecular bone parameters measurements were taken. Both trabecular number and trabecular separation were increased in thicker structures meanwhile bone volume fraction and trabecular thickness values were inconsistent with the increment of the structure thickness. The bone volume fraction, trabecular thickness and trabecular separation were higher in larger voxel size and vice versa for trabecular number. The scanning acquisition time has no apparent correlation with the trabecular bone parameters. The thickness of the bone structure did affect trabecular number and trabecular separation significantly but less affecting bone volume fraction and trabecular thickness. All trabecular bone parameters were found affected by the size of scanning voxel size used. The usage of 35 mu m voxel was more recommended than 18 mu m to save time and give out less radiation dose to specimen unless the detailed features of the trabecular pattern was very important.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 13 条
[1]  
Bae H, 2010, STUD MECHANOBIOL TIS, V2, P153, DOI 10.1007/8415_2010_5
[2]   Automated 3D trabecular bone structure analysis of the proximal femur-prediction of biomechanical strength by CT and DXA [J].
Baum, T. ;
Carballido-Gamio, J. ;
Huber, M. B. ;
Mueller, D. ;
Monetti, R. ;
Raeth, C. ;
Eckstein, F. ;
Lochmueller, E. M. ;
Majumdar, S. ;
Rummeny, E. J. ;
Link, T. M. ;
Bauer, J. S. .
OSTEOPOROSIS INTERNATIONAL, 2010, 21 (09) :1553-1564
[3]   Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography [J].
Bouxsein, Mary L. ;
Boyd, Stephen K. ;
Christiansen, Blaine A. ;
Guldberg, Robert E. ;
Jepsen, Karl J. ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) :1468-1486
[4]   Three-dimensional micro-level computational study of Wolff's law via trabecular bone remodeling in the human proximal femur using design space topology optimization [J].
Boyle, Christopher ;
Kim, Il Yong .
JOURNAL OF BIOMECHANICS, 2011, 44 (05) :935-942
[5]  
Christiansen Blaine A, 2016, Bone Rep, V5, P136, DOI 10.1016/j.bonr.2016.05.006
[6]   Micro-CT of rodents: State-of-the-art and future perspectives [J].
Clark, D. P. ;
Badea, C. T. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06) :619-634
[7]   Sex differences of human trabecular bone micirostructure in aging are site-dependent [J].
Eckstein, Felix ;
Matsuura, Maiko ;
Kuhn, Volker ;
Priemel, Mathias ;
Mueller, Ralph ;
Link, Thomas M. ;
Lochmueller, Eva-Maria .
JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 (06) :817-824
[8]   Micro-CT in small animal and specimen imaging [J].
Holdsworth, David W. ;
Thornton, Michael M. .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) :S34-S39
[9]   Variation of trabecular microarchitectural parameters in cranial, caudal and mid-vertebral regions of the ovine L3 vertebra [J].
Kennedy, Oran D. ;
Brennan, Orlaith ;
Rackard, Susan M. ;
O'Brien, Fergal J. ;
Taylor, David ;
Lee, T. Clive .
JOURNAL OF ANATOMY, 2009, 214 (05) :729-735
[10]   The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone [J].
Kim, DG ;
Christopherson, GT ;
Dong, XN ;
Fyhrie, DP ;
Yeni, YN .
BONE, 2004, 35 (06) :1375-1382